Real-Time Detection of Aerosol Metals Using Online Extractive Electrospray Ionization Mass Spectrometry

被引:25
作者
Giannoukos, Stamatios [1 ,2 ]
Lee, Chuan Ping [1 ]
Tarik, Mohamed [2 ]
Ludwig, Christian [2 ,3 ]
Biollaz, Serge [2 ]
Lamkaddam, Houssni [1 ]
Baltensperger, Urs [1 ]
Prevot, Andre Stephan Henry [1 ]
Slowik, Jay [1 ]
机构
[1] Paul Scherrer Inst, Lab Atmospher Chem, CH-5232 Villigen, Switzerland
[2] Paul Scherrer Inst, Bioenergy & Catalysis Lab, CH-5232 Villigen, Switzerland
[3] Ecole Polytech Fed Lausanne, Engn ENAC, CH-1015 Lausanne, Switzerland
基金
瑞士国家科学基金会; 欧盟地平线“2020”;
关键词
D O I
10.1021/acs.analchem.9b04480
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Metal emissions are of major environmental and practical concern because of their highly toxic effects on human health and ecosystems. Current technologies available in the market for their detection are typically limited by a time resolution of 1 h or longer (e.g., via semicontinuous X-ray fluorescence measurements) or are nonquantitative (e.g., laser ablation mass spectrometry). In this work, we report the development of a novel technique for the real-time detection and monitoring of metal particles in situ using an extractive electrospray ionization (EESI) source coupled to a high -resolution time -of-flight mass spectrometer (TOF-MS). The experiments were conducted in negative ionization mode using disodium ethylenediamine tetraacetic acid (EDTA) dihydrate to chelate with metals and form stable metal complexes. Results for water-soluble metal compounds were obtained. The following representative metal ions were examined: Pb, Cd, Zn, Ce (III), Ba, Ni, Fe(II), Fe(III), Cu(II), Cr, Mo, Co(II), Mg, Nd, Li, Ti, Ca, Cs, Ag, Tm, Er(III), La(III), Yb(III), Eu(III), Pr(III), Gd(III), Lu(III), Dy(III), Tb(III), Ho, and Ru(III). The results showed a very good linear mass response (R-2 = 0.9983), low ng/m(3) limits of detection (LoD), and a fast response time (1 s). The stability and repeatability of the developed EESI-TOF-MS were tested under complex dynamic and periodic experimental conditions, and negligible matrix effects were measured for internally and externally mixed metal particles. Benchmark testing against inductively coupled plasma-mass spectrometry (ICP-MS) was also performed, highlighting the online measurement capabilities of aerosol metals with a LoD lower than those of ICP-MS. Proof-of-concept ambient measurements were performed in New Delhi, India, and very promising results were obtained, allowing further exploitation elsewhere.
引用
收藏
页码:1316 / 1325
页数:10
相关论文
共 43 条
  • [1] Andersson J., 2007, APPL CATAL B-ENVIRON, V2007, P7271
  • [2] [Anonymous], 2021, Review of evidence on health aspects of air pollution: REVIHAAP project: Technical report (No. WHO/EURO: 2013-4101-43860-61757
  • [3] Bartholomew C. H., 2001, APPL CATAL A-GEN, P21217
  • [4] Chemical and microphysical characterization of ambient aerosols with the aerodyne aerosol mass spectrometer
    Canagaratna, M. R.
    Jayne, J. T.
    Jimenez, J. L.
    Allan, J. D.
    Alfarra, M. R.
    Zhang, Q.
    Onasch, T. B.
    Drewnick, F.
    Coe, H.
    Middlebrook, A.
    Delia, A.
    Williams, L. R.
    Trimborn, A. M.
    Northway, M. J.
    DeCarlo, P. F.
    Kolb, C. E.
    Davidovits, P.
    Worsnop, D. R.
    [J]. MASS SPECTROMETRY REVIEWS, 2007, 26 (02) : 185 - 222
  • [5] Chen YJ, 2006, CHEM COMMUN, P1015, DOI 10.1039/b513921j
  • [6] Cisper ME, 1997, RAPID COMMUN MASS SP, V11, P1454
  • [7] Cooks IL G., 2006, SCIENCE
  • [8] Cooper J. A., 2010, GUIDE DEV MULTIMETAL
  • [9] Daellenbach K. R., 2017, ATMOS CHEM PHYS
  • [10] Dockery D. W., 1994, ANNU REV PUBL HEALTH, P15107