In vivo measurement of lead in the bones of smelter workers using the four-element 'clover-leaf' geometry detector system

被引:9
作者
Behinaein, Sepideh [1 ]
Chettle, David R. [1 ]
Atanackovic, Jovica [2 ]
Egden, Lesley M. [1 ]
Fleming, David E. B. [3 ]
Nie, Linda H. [4 ]
Richard, Norbert [5 ]
Stever, Susan [5 ]
机构
[1] McMaster Univ, Dept Med Phys & Appl Radiat Sci, Hamilton, ON L8S 4K1, Canada
[2] AECL Res, Chalk River Labs, Dosimetry Serv, Chalk River, ON K0J 1J0, Canada
[3] Mt Allison Univ, Dept Phys, Sackville, NB E4L 1E6, Canada
[4] Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USA
[5] Xstrata Zinc, Occupat Hlth Serv, Brunswick Smelter, Belledune, NB E8G 2M1, Canada
基金
加拿大创新基金会; 加拿大健康研究院;
关键词
X-RAY-FLUORESCENCE; BLOOD LEAD; EXPOSURE;
D O I
10.1088/0031-9155/56/3/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A total of 497 smelter employees from New Brunswick participated in a bone lead survey conducted by McMaster University in 2008 to examine the efficiency of lead exposure control programmes and a four-element 'clover-leaf' geometry detector system. Nearly 42% of the subjects had participated in both the previous surveys performed in 1994 and 1999. After developing the clover-leaf geometry system in 2006, the reliability of the system based on examining the consistency of four detectors and improving the minimum detection limit (MDL) was tested for the first time in 2008 by measuring lead levels of a large population that was occupationally exposed to lead. The Z test was used to study the distribution of the lead concentration calculated based on K-alpha and K-beta lead x-rays, where the results were broadly consistent with a normal distribution criterion, with relatively small means and standard deviations of between 1 and 2. The MDL of the clover-leaf geometry system was improved on average for tibia and calcaneus by a factor of 3.1 compared to the 1999 and 1994 surveys in which a conventional system (one detector) was used. Furthermore, by comparing the results of the three mentioned surveys, the 2008 results were found to represent the highest precision.
引用
收藏
页码:653 / 665
页数:13
相关论文
共 29 条
  • [1] AHLGREN L, 1976, Scandinavian Journal of Work Environment and Health, V2, P82
  • [2] [Anonymous], STAT MEANING METHOD
  • [3] [Anonymous], NUCL INSTRUM METHO A
  • [4] [Anonymous], STAT FDN ANAL
  • [5] [Anonymous], IEEE T NUCL SCI
  • [6] [Anonymous], BASIC STAT
  • [7] BARRY PSI, 1975, BRIT J IND MED, V32, P119
  • [8] Borja-Aburto VH, 1999, AM J EPIDEMIOL, V150, P590, DOI 10.1093/oxfordjournals.aje.a010057
  • [9] Lead exposure inhibits fracture healing and is associated with increased chondrogenesis, delay in cartilage mineralization, and a decrease in osteoprogenitor frequency
    Carmouche, JJ
    Puzas, JE
    Zhang, XP
    Tiyapatanaputi, P
    Cory-Slechta, DA
    Gelein, R
    Zuscik, M
    Rosier, RN
    Boyce, BF
    O'Keefe, RJ
    Schwarz, EM
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2005, 113 (06) : 749 - 755
  • [10] Early exposure to lead and juvenile delinquency
    Dietrich, KN
    Ris, MD
    Succop, PA
    Berger, OG
    Bornschein, RL
    [J]. NEUROTOXICOLOGY AND TERATOLOGY, 2001, 23 (06) : 511 - 518