Luminescent metal-organic framework-based phosphor for the detection of toxic oxoanions in an aqueous medium

被引:36
作者
Singha, Debal Kanti [1 ,2 ]
Majee, Prakash [2 ]
Hui, Sayani [1 ]
Mondal, Sudip Kumar [2 ]
Mahata, Partha [1 ]
机构
[1] Jadavpur Univ, Dept Chem, Kolkata 700032, India
[2] Visva Bharati Univ, Dept Chem, Santini Ketan 731235, W Bengal, India
关键词
COORDINATION POLYMER; CHROMATE ANIONS; SELECTIVE DETECTION; SENSITIZED LUMINESCENCE; FUNCTIONAL LUMINESCENT; FLUORESCENT SENSOR; SINGLE-CRYSTAL; QUANTUM DOTS; IONS; CHROMIUM;
D O I
10.1039/c9dt04220b
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A terbium-doped yttrium-based metal-organic framework, [Tb0.2Y0.8(FDA)(Ox)(0.5)(H2O)(2)]center dot H2O, 1 {where H(2)FDA = furan-2,5-dicarboxylic acid and Ox = oxalate}, was successfully synthesized using the hydrothermal technique as a phosphor material along with a large Stokes shift and low self-quenching of luminescence for the rapid visible detection of toxic anions in an aqueous medium. To confirm the structure and phase purity of compound 1, single crystals of the isomorphous pure yttrium-based compound [Y(FDA)(Ox)(0.5)(H2O)(2)]center dot H2O, 1a, were synthesized under similar experimental conditions. The single crystal X-ray data of compound 1a confirmed the three-dimensional metal-organic framework formed by the connectivity of the Y3+ ion with furan-2,5-dicarboxylate and the oxalate moiety. The phase purity of compounds 1 and 1a was confirmed by powder X-ray diffraction. Compound 1 was systematically characterized via TGA, SEM and EDX elemental mapping analysis. The aqueous dispersion of compound 1 showed highly intense visible green emission upon excitation at 265 nm. The emissions of compound 1 were utilized for the luminescence-based visible detection of toxic anions in the aqueous medium through luminescence quenching. The observed limit of detection (LOD) was 1.1 nM, 2.2 nM and 6.5 nM for chromate (CrO42-), permanganate (MnO4-) and phosphates (PO43-, H2PO4- and HPO42-), respectively, and the observed K-SV values were superior to those of all other metal-organic frameworks previously reported. More importantly, the LODs are significantly lower than the level recommended for these anions towards human life.
引用
收藏
页码:829 / 840
页数:12
相关论文
共 115 条
  • [1] [Anonymous], 1987, ANALYST, V112, P199
  • [2] [Anonymous], 2004, SMART V 5 628 SAINT
  • [3] [Anonymous], 2012, Agency for Toxic Substances and Disease Registry (ATSDR) Toxicological Profiles. Toxicological Profile for Chromium
  • [4] [Anonymous], 2018, Guidelines for Drinking Water Quality, DOI DOI 10.101651462-0758(00)00006-6
  • [5] [Anonymous], 1994, SIEMENS AREA CORRECT
  • [6] Complete Transmetalation in a Metal-Organic Framework by Metal Ion Metathesis in a Single Crystal for Selective Sensing of Phosphate Ions in Aqueous Media
    Asha, K. S.
    Bhattacharjee, Rameswar
    Mandal, Sukhendu
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2016, 55 (38) : 11528 - 11532
  • [7] Cytotoxicity and oxidative mechanisms of different forms of chromium
    Bagchi, D
    Stohs, SJ
    Downs, BW
    Bagchi, M
    Preuss, HG
    [J]. TOXICOLOGY, 2002, 180 (01) : 5 - 22
  • [8] Graphene Quantum Dots Combined with Europium Ions as Photoluminescent Probes for Phosphate Sensing
    Bai, Jian-Mei
    Zhang, Li
    Liang, Ru-Ping
    Qiu, Jian-Ding
    [J]. CHEMISTRY-A EUROPEAN JOURNAL, 2013, 19 (12) : 3822 - 3826
  • [9] High-throughput synthesis of zeolitic imidazolate frameworks and application to CO2 capture
    Banerjee, Rahul
    Phan, Anh
    Wang, Bo
    Knobler, Carolyn
    Furukawa, Hiroyasu
    O'Keeffe, Michael
    Yaghi, Omar M.
    [J]. SCIENCE, 2008, 319 (5865) : 939 - 943
  • [10] Two solvent-stable MOFs as a recyclable luminescent probe for detecting dichromate or chromate anions
    Cao, Chun-Shuai
    Hu, Huan-Cheng
    Xu, Hang
    Qiao, Wan-Zhen
    Zhao, Bin
    [J]. CRYSTENGCOMM, 2016, 18 (23): : 4445 - 4451