Current status of urban wastewater treatment plants in China

被引:468
作者
Zhang, Q. H. [1 ,2 ]
Yang, W. N. [2 ]
Ngo, H. H. [3 ]
Guo, W. S. [3 ]
Jin, P. K. [2 ]
Dzakpasu, Mawuli [2 ]
Yang, S. J. [1 ]
Wang, Q. [1 ]
Wang, X. C. [1 ]
Ao, D. [1 ]
机构
[1] Xian Univ Architecture & Technol, Key Lab Northwest Water Resource Environm & Ecol, Minist Educ, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian 710055, Peoples R China
[3] Univ Technol Sydney, Ctr Technol Water & Wastewater, Sch Civil & Environm Engn, POB 123, Sydney, NSW 2007, Australia
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
Wastewater treatment plants (WWTPs); Regional sewage treatment; Discharge standard and upgrading; Sludge disposal; Energy consumption; Wastewater reclamation and reuse; SEWAGE-SLUDGE; HEAVY-METAL; SPECIATION;
D O I
10.1016/j.envint.2016.03.024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study reported and analyzed the current state of wastewater treatment plants (WWTPs) in urban China from the perspective of treatment technologies, pollutant removals, operating load and effluent discharge standards. By the end of 2013, 3508 WWTPs have been built in 31 provinces and cities in China with a total treatment capacity of 1.48 x 10(8) m(3)/d. The uneven population distribution between China's east and west regions has resulted in notably different economic development outcomes. The technologies mostly used in WWTPs are MO and oxidation ditch, which account for over 50% of the existing WWTPs. According to statistics, the efficiencies of COD and NH3-N removal are good in 656 WWTPs in 70 cities. The overall average COD removal is over 88% with few regional differences. The average removal efficiency of NH3-N is up to 80%. Large differences exist between the operating loads applied in different WWTPs. The average operating loading rate is approximately 83%, and 52% of WWTPs operate at loadings of <80%, treating up to 40% of the wastewater generated. The implementation of discharge standards has been low. Approximately 28% of WWTPs that achieved the Grade I-A Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918-2002) were constructed after 2010. The sludge treatment and recycling rates are only 25%, and approximately 15% of wastewater is inefficiently treated. Approximately 60% of WWTPs have capacities of 1 x 10(4) m(3)/d-5 x 10(4) m(3)/d. Relatively high energy consumption is required for small-scale processing, and the utilization rate of recycled wastewater is low. The challenges of WWTPs are discussed with the aim of developing rational criteria and appropriate technologies for water recycling. Suggestions regarding potential technical and administrative measures are provided. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:11 / 22
页数:12
相关论文
共 51 条
[31]   A supervisory control system for optimising nitrogen removal and aeration energy consumption in wastewater treatment plants [J].
Serralta, J ;
Ribes, J ;
Seco, A ;
Ferrer, J .
WATER SCIENCE AND TECHNOLOGY, 2002, 45 (4-5) :309-316
[32]   Modeling Energy Consumption in Membrane Bioreactors for Wastewater Treatment in North Africa [J].
Skouteris, George ;
Arnot, Tom C. ;
Jraou, Mouna ;
Feki, Firas ;
Sayadi, Sami .
WATER ENVIRONMENT RESEARCH, 2014, 86 (03) :232-244
[33]   The Need for Industry and Occupation Standards in Hospital Discharge Data [J].
Taylor, Jennifer A. ;
Frey, Leslie T. .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2013, 55 (05) :495-499
[34]   EC treatment for reuse of tissue paper wastewater: Aspects that affect energy consumption [J].
Terrazas, Eduardo ;
Vazquez, Armando ;
Briones, Roberto ;
Lazaro, Isabel ;
Rodriguez, Israel .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 181 (1-3) :809-816
[35]   Growth parameters and heavy metal accumulation in poplar tree cultures (Populus euramericana) utilizing water and sludge from a sewage treatment plant [J].
Tsakou, A ;
Roulia, M ;
Christodoulakis, NS .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2003, 71 (02) :330-337
[36]   Environmental impact analysis of chemicals and energy consumption in wastewater treatment plants: case study of Oslo, Norway [J].
Venkatesh, G. ;
Brattebo, Helge .
WATER SCIENCE AND TECHNOLOGY, 2011, 63 (05) :1018-1031
[37]   Heavy Metal Removal from Sewage Sludge Ash by Thermochemical Treatment with Polyvinylchloride [J].
Vogel, Christian ;
Exner, Robert M. ;
Adam, Christian .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (01) :563-567
[38]  
Wang C.J., 2013, ANAL STUDY PROBLEM E
[39]   Modeling heavy metal uptake by sludge particulates in the presence of dissolved organic matter [J].
Wang, JM ;
Huang, CP ;
Allen, HE .
WATER RESEARCH, 2003, 37 (20) :4835-4842
[40]   Transformation of heavy metal speciation during sludge drying: Mechanistic insights [J].
Weng, Huan-Xin ;
Ma, Xue-Wen ;
Fu, Feng-Xia ;
Zhang, Jin-Jun ;
Liu, Zan ;
Tian, Li-Xun ;
Liu, Chongxuan .
JOURNAL OF HAZARDOUS MATERIALS, 2014, 265 :96-103