Definition of an Indoor Air Sampling Strategy for SARS-CoV-2 Detection and Risk Management: Case Study in Kindergartens

被引:4
|
作者
Borgese, Laura [1 ,2 ,3 ]
Tomasoni, Giuseppe [4 ]
Marciano, Filippo [4 ]
Zacco, Annalisa [1 ,2 ,3 ]
Bilo, Fabjola [1 ,2 ,3 ]
Stefana, Elena [4 ]
Cocca, Paola [4 ]
Rossi, Diana [4 ]
Cirelli, Paola [5 ]
Ciribini, Angelo Luigi Camillo [6 ]
Comai, Sara [6 ]
Ventura, Silvia Mastrolembo [6 ]
Boles, Michela Savoldi [7 ]
Micheletti, Diletta [7 ]
Cattivelli, Daniela [8 ]
Galletti, Serena [8 ]
Dubacq, Sophie [9 ]
Perrone, Maria Grazia [10 ,11 ]
Depero, Laura Eleonora [1 ,2 ,3 ]
机构
[1] Univ Brescia, Dept Mech & Ind Engn, INSTM, Via Branze 38, I-25123 Brescia, Italy
[2] Univ Brescia, Dept Mech & Ind Engn, Chem Technol Lab, Via Branze 38, I-25123 Brescia, Italy
[3] Smart Solut Srl, Via Corfu 106, I-25124 Brescia, Italy
[4] Univ Brescia, Dept Mech & Ind Engn, Via Branze 38, I-25123 Brescia, Italy
[5] Univ Brescia, Dept Informat Engn, Via Branze 38, I-25123 Brescia, Italy
[6] Univ Brescia, Dept Civil & Environm Engn Architecture & Math, Via Branze 43, I-25123 Brescia, Italy
[7] BIOSIDE Srl, Via A Einstein, I-26900 Lodi, Italy
[8] AAT Adv Analyt Technol Srl, Via P Majavacca 12, I-29017 Fiorenzuola Darda, Italy
[9] Bertin Instruments Brand Bertin Technol SAS, 10 Bis Ave Ampere, F-78180 Montigny Le Bretonneux, France
[10] TCR Tecora Srl, Via Primule 16, I-20815 Cogliate, Italy
[11] XearPro Srl, Via Primule 16, I-20815 Cogliate, Italy
关键词
COVID-19; risk assessment and control; hazard identification; aerosol transmission; droplet transmission; bioaerosol sampling; sampling plan; standard guideline; school; AIRBORNE MICROORGANISMS; CONTAMINATION; TRANSMISSION; ENVIRONMENTS; COLLECTION; BACTERIA;
D O I
10.3390/ijerph19127406
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the last two years, the world has been overwhelmed by SARS-CoV-2. One of the most important ways to prevent the spread of the virus is the control of indoor conditions: from surface hygiene to ventilation. Regarding the indoor environments, monitoring the presence of the virus in the indoor air seems to be promising, since there is strong evidence that airborne transmission through infected droplets and aerosols is its dominant transmission route. So far, few studies report the successful detection of SARS-CoV-2 in the air; moreover, the lack of a standard guideline for air monitoring reduces the uniformity of the results and their usefulness in the management of the risk of virus transmission. In this work, starting from a critical analysis of the existing standards and guidelines for indoor air quality, we define a strategy to set-up indoor air sampling plans for the detection of SARS-CoV-2. The strategy is then tested through a case study conducted in two kindergartens in the metropolitan city of Milan, in Italy, involving a total of 290 children and 47 teachers from 19 classrooms. The results proved its completeness, effectiveness, and suitability as a key tool in the airborne SARS-CoV-2 infection risk management process. Future research directions are then identified and discussed.
引用
收藏
页数:19
相关论文
共 50 条
  • [11] Investigation of hospital indoor air quality for the presence of SARS-Cov-2
    Hossein Masoumbeigi
    Ghader Ghanizadeh
    Reza Yousefi Arfaei
    Soleyman Heydari
    Hassan Goodarzi
    Ruhollah Dorostkar Sari
    Mehdi Tat
    Journal of Environmental Health Science and Engineering, 2020, 18 : 1259 - 1263
  • [12] Indoor Air Changes and Potential Implications for SARS-CoV-2 Transmission
    Allen, Joseph G.
    Ibrahim, Andrew M.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 325 (20): : 2112 - 2113
  • [13] Investigation of hospital indoor air quality for the presence of SARS-Cov-2
    Masoumbeigi, Hossein
    Ghanizadeh, Ghader
    Yousefi Arfaei, Reza
    Heydari, Soleyman
    Goodarzi, Hassan
    Dorostkar Sari, Ruhollah
    Tat, Mehdi
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2020, 18 (02) : 1259 - 1263
  • [14] Self-sampling for SARS-CoV-2 Detection in Children
    Youngster, Ilan
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2022, 328 (10): : 929 - 930
  • [15] Case study of SARS-CoV-2 transmission risk assessment in indoor environments using cloud computing resources
    Saurabh, Kumar
    Adavani, Santi
    Tan, Kendrick
    Ishii, Masado
    Gao, Boshun
    Krishnamurthy, Adarsh
    Sundar, Hari
    Ganapathysubramanian, Baskar
    SCWS 2021: 2021 SC WORKSHOPS SUPPLEMENTARY PROCEEDINGS, 2021, : 79 - 86
  • [16] Hospital indoor air quality monitoring for the detection of SARS-CoV-2 (COVID-19) virus
    Kenarkoohi, Azra
    Noorimotlagh, Zahra
    Falahi, Shahab
    Amarloei, Ali
    Mirzaee, Seyyed Abbas
    Pakzad, Iraj
    Bastani, Elham
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 748
  • [17] SARS-CoV-2 detection in aerosol from community indoor environments
    Alfaro, C.
    Porru, S.
    Barbera-Riera, M.
    Esplugues, A.
    Galindo, N.
    Carrasco, P.
    Aparicio, E.
    Barneo-Munoz, M.
    Estarlich, M.
    Esteve-Cano, V.
    Ballester, F.
    Rebagliato, M.
    Iniguez, C.
    Bellido-Blasco, J. B.
    de Llanos, R.
    Delgado-Saborit, J. M.
    BUILDING AND ENVIRONMENT, 2024, 261
  • [18] Pooled Sampling is an Efficient and Economical Strategy for SARS-CoV-2 Detection in Low-Prevalence Areas
    Sun, Xiang
    Deng, Li
    Zhan, Xuan
    Chen, Xiaojing
    Yang, Xiaohui
    Huang, Yingfeng
    Chen, XinChun
    Zheng, Weidong
    CLINICAL LABORATORY, 2022, 68 (05) : 2390 - 2395
  • [19] Pooled Sampling is an Efficient and Economical Strategy for SARS-CoV-2 Detection in Low-Prevalence Areas
    Sun, Xiang
    Deng, Li
    Zhan, Xuan
    Chen, Xiaojing
    Yang, Xiaohui
    Huang, Yingfeng
    Chen, XinChun
    Zheng, Weidong
    CLINICAL LABORATORY, 2021,
  • [20] Comparing and validating air sampling methods for SARS-CoV-2 detection in HVAC ducts of student dorms
    Sousan, Sinan
    Boatman, Marina
    Johansen, Lauren
    Fan, Ming
    Roper, Rachel L.
    ENVIRONMENTAL POLLUTION, 2024, 343