Evaluation of the accuracy of manual and automatic scoring of a single airflow channel in patients with a high probability of obstructive sleep apnea

被引:30
作者
BaHammam, Ahmed [1 ]
Sharif, Munir [1 ]
Gacuan, Divinagracia E. [1 ]
George, Smitha [1 ]
机构
[1] King Saud Univ, Univ Sleep Disorders Ctr, Coll Med, Riyadh 11324, Saudi Arabia
来源
MEDICAL SCIENCE MONITOR | 2011年 / 17卷 / 02期
关键词
sleep-disordered breathing; sleep apnea; ApneaLink; polysomnography; type 4 sleep study; portable monitoring;
D O I
10.12659/MSM.881379
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: ApneaLink (TM) (AL) is a single-channel type-4 device that measures airflow. A limited number of studies have assessed AL's usefulness in diagnosing obstructive sleep apnea (OSA) using automated scoring alone. This study was conducted to assess the sensitivity and specificity of AL in a selected group of people with clinical suspicion of OSA, using both automatic and manual scoring and comparing the results with those obtained for polysomnography (PSG). Material/Methods: Simultaneous overnight recordings of in-laboratory PSG and AL were performed for 95 patients (mean age 46.3 +/- 12.6 yr) with a high clinical suspicion of OSA. PSG was scored manually according to the American Academy of Sleep Medicine (AASM) guidelines. AL data were analyzed automatically using a manufacturer-provided computerized algorithm. Manual scoring of the AL flow signal followed the AASM guidelines for reduction in flow. Results: The mean apnea hypopneas index (AHI) for PSG was 34.1 +/- 32.4/hr. The AL Auto-AHI was 20.1 +/- 25.2/h, and the AL Manual-AHI was 39.5 +/- 30.4/h. The Pearson correlation coefficients were r = 0.883 between PSG-AHI and AL Auto-AHI, and r = 0.966 between PSG-AHI and AL Manual-AHI. At AHIs of 5, 10, 15, and 30, the AL Auto sensitivity/specificity was 0.79/0.68, 0.70/0.89, 0.64/0.94 and 0.63/0.98, and the AL Manual sensitivity/specificity was 1.00/0.43, 1.00/0.56, 0.98/0.58 and 1.00/0.80. Conclusions: Combining auto and manual scoring of data (automatic scoring followed by manual scoring) recorded by single-channel ApneaLink (TM) provides good diagnostic agreement with conventional PSG recordings.
引用
收藏
页码:MT13 / MT19
页数:7
相关论文
共 16 条
[1]  
[Anonymous], 1999, SLEEP, V22, P667
[2]  
BaHammam AS, 2007, SAUDI MED J, V28, P917
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Evaluation of a portable recording device (ApneaLink™) for case selection of obstructive sleep apnea [J].
Chen, Hui ;
Lowe, Alan A. ;
Bai, Yuxing ;
Hamilton, Peter ;
Fleetham, John A. ;
Almeida, Fernanda R. .
SLEEP AND BREATHING, 2009, 13 (03) :213-219
[5]   Use of a screening tool for detection of sleep-disordered breathing [J].
Clark, A. L. ;
Crabbe, S. ;
Aziz, A. ;
Reddy, P. ;
Greenstone, M. .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2009, 123 (07) :746-749
[6]  
Collop NA, 2007, J CLIN SLEEP MED, V3, P737
[7]   Statistics notes - Diagnostic tests 4: likelihood ratios [J].
Deeks, JJ ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 2004, 329 (7458) :168-169
[8]  
Erman MK, 2007, J CLIN SLEEP MED, V3, P387
[9]   PORTABLE RECORDING IN THE ASSESSMENT OF OBSTRUCTIVE SLEEP-APNEA [J].
FERBER, R ;
MILLMAN, R ;
COPPOLA, M ;
FLEETHAM, J ;
MURRAY, CF ;
IBER, C ;
MCCALL, V ;
NINOMURCIA, G ;
PRESSMAN, M ;
SANDERS, M ;
STROHL, K ;
VOTTERI, B ;
WILLIAMS, A .
SLEEP, 1994, 17 (04) :378-392
[10]  
Iber C., 2007, AASM MANUAL SCORING