High-resolution time-resolved contrast-enhanced MR abdominal and pulmonary angiography using a Spiral-TRICKS sequence

被引:26
作者
Du, Jiang [1 ]
Bydder, Mark [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
关键词
gradient distortion; magnetic resonance angiography; spiral trajectories; three-dimensional; time-resolved MRA;
D O I
10.1002/mrm.21298
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Both high spatial resolution and high temporal resolution are desirable for contrast-enhanced magnetic resonance angiography (CE-MRA) in order to depict the arterial vasculature. In this work a fast MR pulse sequence (spiral time-resolved imaging with contrast kinetics (Spiral-TRICKS)) with spiral readout in-plane and Cartesian slice encoding was developed whereby the slices are partitioned into multiple regions and acquire n the order used with the TRICKS sequence. The combination of highly efficient spiral sampling with TRICKS acquisition significantly reduced imaging time requirements. A unit second temporal reconstructed frame rate could be achieved for threedimensional (3D) CE-MRA without undersampling of the spiral trajectories. Image quality was improved through spiral trajectory measurement and field-map correction. Phantom and volunteer studies were performed to demonstrate the feasibility of this technique.
引用
收藏
页码:631 / 635
页数:5
相关论文
共 23 条
  • [1] Three-dimensional spiral MR imaging: Application to renal multiphase contrast-enhanced angiography
    Amann, M
    Bock, M
    Floemer, F
    Schoenberg, SO
    Schad, LR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) : 290 - 296
  • [2] Time-resolved three-dimensional pulmonary MR angiography and perfusion imaging with ultrashort repetition time
    Carr, JC
    Laub, G
    Zheng, J
    Pereles, FS
    Finn, JP
    [J]. ACADEMIC RADIOLOGY, 2002, 9 (12) : 1407 - 1418
  • [3] Contrast-enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction
    Du, J
    Carroll, TJ
    Brodsky, E
    Lu, AM
    Grist, TM
    Mistretta, CA
    Block, WF
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) : 894 - 900
  • [4] Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels
    Du, J
    Carroll, TJ
    Wagner, HJ
    Vigen, K
    Fain, SB
    Block, WF
    Korosec, FR
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) : 516 - 522
  • [5] Simple correction method for k-space trajectory deviations in MRI
    Duyn, JH
    Yang, YH
    Frank, JA
    van der Veen, JW
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1998, 132 (01) : 150 - 153
  • [6] IMPROVED EJECTION FRACTION AND FLOW VELOCITY ESTIMATES WITH USE OF VIEW SHARING AND UNIFORM REPETITION TIME EXCITATION WITH FAST CARDIAC TECHNIQUES
    FOO, TKF
    BERNSTEIN, MA
    AISEN, AM
    HERNANDEZ, RJ
    COLLICK, BD
    BERNSTEIN, T
    [J]. RADIOLOGY, 1995, 195 (02) : 471 - 478
  • [7] Inhomogeneity correction using an estimated linear field map
    Irarrazabal, P
    Meyer, CH
    Nishimura, DG
    Macovski, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) : 278 - 282
  • [8] Simulated phase evolution rewinding (SPHERE): A technique for reducing B-0 inhomogeneity effects in MR images
    Kadah, YM
    Hu, XP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) : 615 - 627
  • [9] OPTIMIZED GRADIENT WAVE-FORMS FOR SPIRAL SCANNING
    KING, KF
    FOO, TKF
    CRAWFORD, CR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) : 156 - 160
  • [10] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351