Anisotropic response of the human knee joint meniscus to unconfined compression

被引:42
作者
Leslie, BW
Gardner, DL
McGeough, JA
Moran, RS
机构
[1] Univ Edinburgh, Sch Mech Engn, Div Engn, Edinburgh EH9 3JL, Midlothian, Scotland
[2] Univ Edinburgh, Sch Med, Dept Pathol, Edinburgh, Midlothian, Scotland
关键词
meniscus; human knee joint; compressive testing; mechanical properties;
D O I
10.1243/0954411001535651
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The response of meniscal tissue to axial, radial and circumferential compressive forces was measured at physiologically relevant levels of load in eight pairs of human knee joint menisci. Compression was unconfined and uniaxial. Stress-strain data were fitted to a two-parameter exponential model. The tissue was found to be significantly stiffer to axial compressive forces than to radial and circumferential forces. No significant difference was found between the responses to circumferential and radial forces.
引用
收藏
页码:631 / 635
页数:5
相关论文
共 19 条
  • [1] Adams ME, 1992, KNEE MENISCUS BASIC, P15
  • [2] INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .1. TIBIAL SURFACE OF THE KNEE
    AHMED, AM
    BURKE, DL
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03): : 216 - 225
  • [3] [Anonymous], T ORTHOP RES SOC
  • [4] [Anonymous], 1989, T ORTHOP RES SOC
  • [5] BEAUPRE A, 1986, CLIN ORTHOP RELAT R, V208, P72
  • [6] Bullough P G, 1970, J Bone Joint Surg Br, V52, P564
  • [7] FITHIAN DC, 1990, CLIN ORTHOP RELAT R, P19
  • [8] ELASTICITY OF SOFT TISSUES IN SIMPLE ELONGATION
    FUNG, YCB
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1967, 213 (06): : 1532 - +
  • [9] KUROSAWA H, 1980, CLIN ORTHOP RELAT R, V149, P283
  • [10] Leslie BW, 1998, ACTA ANAT, V163, P212