Numerical Simulation of Generalized Newtonian Blood Flow Past a Couple of Irregular Arterial Stenoses

被引:16
作者
Mustapha, Norzieha [2 ]
Mandal, Prashanta K. [3 ]
Abdullah, Ilyani [2 ]
Amin, Norsarahaida [2 ]
Hayat, Tasawar [1 ]
机构
[1] Quaid I Azam Univ, Dept Math, Islamabad 44000, Pakistan
[2] Univ Teknol Malaysia, Fac Sci, Dept Math, Utm Skudai 81310, Malaysia
[3] Visva Bharati, Dept Math, Santini Ketan 731235, W Bengal, India
关键词
non-Newtonian flow; MAC method; flow separation; Shear-dependent viscosity; RIGHT CORONARY-ARTERIES; PULSATILE FLOW; SURFACE IRREGULARITIES; RESISTANCE; MULTIPLE; MODELS; FLUID;
D O I
10.1002/num.20563
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
This paper looked at the numerical investigations of the generalized Newtonian blood flowthrough a couple of irregular arterial stenoses. The flowis treated to be axisymmetric, with an outline of the stenoses obtained from a three dimensional casting of a mild stenosed artery, so that the flow effectively becomes two-dimensional. The Marker and Cell (MAC) method is developed for the governing unsteady generalized Newtonian equations in staggered grid for viscous incompressible flow in the cylindrical polar co-ordinates system. The derived pressure-Poisson equation was solved using Successive-Over-Relaxation (S.O.R.) method and the pressure-velocity correction formulae have been derived. Computations are performed for the pressure drop, the wall shear stress distribution and the separation region. The presented computations show that in comparison to the corresponding Newtonian model the generalized Newtonian fluid experiences higher pressure drop, lower peakwall shear stress and smaller separation region. (C) 2010 Wiley Periodicals, Inc. Numer Methods Partial Differential Eq 27: 960-981, 2011
引用
收藏
页码:960 / 981
页数:22
相关论文
共 40 条
  • [1] Amsden A., 1970, Report LA-4370
  • [2] Effects of surface irregularities on flow resistance in differently shaped arterial stenoses
    Andersson, HI
    Halden, R
    Glomsaker, T
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (10) : 1257 - 1262
  • [3] Ang K. C., 1995, Australasian Physical and Engineering Sciences in Medicine, V18, P89
  • [4] EFFECT OF MILD ATHEROSCLEROSIS ON FLOW RESISTANCE IN A CORONARY-ARTERY CASTING OF MAN
    BACK, LH
    CHO, YI
    CRAWFORD, DW
    CUFFEL, RF
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (01): : 48 - 53
  • [5] A nonlinear mathematical model of blood flow in a constricted artery experiencing body acceleration
    Chakravarty, S
    Sannigrahi, AK
    [J]. MATHEMATICAL AND COMPUTER MODELLING, 1999, 29 (08) : 9 - 25
  • [6] Effect of surface irregularities on unsteady pulsatile flow in a compliant artery
    Chakravarty, S
    Mandal, PK
    Sarifuddin
    [J]. INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2005, 40 (10) : 1268 - 1281
  • [7] CHO YI, 1991, BIORHEOLOGY, V28, P241
  • [8] STEADY LAMINAR-FLOW THROUGH MODELED VASCULAR STENOSES
    DESHPANDE, MD
    GIDDENS, DP
    MABON, RF
    [J]. JOURNAL OF BIOMECHANICS, 1976, 9 (04) : 165 - 174
  • [9] DREUMEL SCV, 1989, ASME, V111, P212
  • [10] FLOW RATE PRESSURE GRADIENT MEASUREMENTS IN PERIODICALLY NONUNIFORM CAPILLARY TUBES
    DULLIEN, FAL
    AZZAM, MIS
    [J]. AICHE JOURNAL, 1973, 19 (02) : 222 - 229