Fuzzy logic-based instantaneous power ripple minimization for direct power control applied in a shunt active power filter

被引:9
作者
Kadem, Mohammed [1 ]
Semmah, Abdelhafid [1 ]
Wira, Patrice [2 ]
Dahmani, Samira [1 ]
机构
[1] Djilali Liabes Univ, Dept Elect Engn, ICEPS Lab, Sidi Bel Abbes, Algeria
[2] Haute Alsace Univ, Inst Res Comp Sci Math Automat & Signal IRIMAS, Mulhouse, France
关键词
Direct power control; Ripple minimization; Active power filter; Harmonic; Fuzzy logic; CONVERTER;
D O I
10.1007/s00202-020-00943-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The high presence of instantaneous active and reactive power ripples when using the direct power control (DPC) strategy in power converters represents a serious issue, especially when used in active power filters (APFs) to compensate harmonics; those ripples are due to the presence of hysteresis controllers and the rigidity of the conventional switching table, and they cause serious limitations in the filtering capabilities of APFs. Many attempts had been proposed to solve this problem, but at the expense of over-complicating the DPC. In this paper, we tackle this problem by shifting toward a fuzzy logic paradigm and creating a fuzzy inference system that replaces the hysteresis controllers and the switching table, and the goal is to reduce the rigidity of the conventional DPC and build a smoother alternative, which will result in less power ripples. The proposed strategy is tested using MATLAB simulations and experimentally validated using an FPGA-based laboratory setup during both steady-state and transient conditions.
引用
收藏
页码:1327 / 1338
页数:12
相关论文
共 23 条
[1]  
Afghoul H, 2013, PROCEEDINGS OF THE 2013 IEEE 7TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO2013), P228
[2]  
Afghoul H., 2012, 2012 IEEE International Energy Conference (ENERGYCON 2012), P146, DOI 10.1109/EnergyCon.2012.6347742
[3]   Active harmonic filters [J].
Akagi, H .
PROCEEDINGS OF THE IEEE, 2005, 93 (12) :2128-2141
[4]  
Alonso-Martinez Jaime., 2011, IEEE T IND ELECTRON, V60, P1442
[5]  
Blvd EV, 2014, INT J IND ELECT DRIV, V1, P174, DOI [10.1504/IJIED.2014.064091, DOI 10.1504/IJIED.2014.064091]
[6]   Power quality improvement using DPC controlled three-phase shunt active filter [J].
Chaoui, Abdelmadjid ;
Gaubert, Jean-Paul ;
Krim, Fateh .
ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (06) :657-666
[7]   Passive filters - Potentialities and limitations [J].
Das, JC .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (01) :232-241
[8]  
Gerardo M., 2015, 1 INT C INSTR APPL S, V1, P1
[9]   Design and Performance of a Three-Phase Fuzzy Logic Controlled Shunt Active Power Filter Control Hardware with a 400 kHz Switching PWM Implemented in FPGA [J].
Gomez, Raphael Ceni ;
Batista, Edson Antonio ;
Godoy, Ruben Barros ;
Leite, Luciana Cambraia ;
Siqueira, Joao Carlos .
JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2014, 25 (01) :1-9
[10]  
Lamterkati J, 2016, 2 INT C EL INF TECHN, V1, P10