Imaging Modalities Employed in Diabetic Retinopathy Screening: A Review and Meta-Analysis

被引:14
|
作者
Kanclerz, Piotr [1 ,2 ]
Tuuminen, Raimo [2 ,3 ]
Khoramnia, Ramin [4 ]
机构
[1] Hygeia Clin, PL-80286 Gdansk, Poland
[2] Univ Helsinki, Fac Med, Helsinki Retina Res Grp, Helsinki 00014, Finland
[3] Kymenlaakso Cent Hosp, Eye Ctr, Kotka 48100, Finland
[4] Heidelberg Univ, Dept Ophthalmol, David J Apple Int Lab Ocular Pathol, D-69120 Heidelberg, Germany
关键词
diabetic retinopathy; fundus photography; mydriatic photography; screening; smartphone-based imaging; ultra-wide-field scanning laser ophthalmoscope; diabetic macular edema; OPTICAL COHERENCE TOMOGRAPHY; NONMYDRIATIC FUNDUS PHOTOGRAPHY; SCANNING LASER OPHTHALMOSCOPY; MACULAR EDEMA; SMARTPHONE OPHTHALMOSCOPY; RETINAL PHOTOGRAPHY; CHOROIDAL THICKNESS; VISUAL-ACUITY; RISK-FACTORS; SLIT-LAMP;
D O I
10.3390/diagnostics11101802
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Urbanization has caused dramatic changes in lifestyle, and these rapid transitions have led to an increased risk of noncommunicable diseases, such as type 2 diabetes. In terms of cost-effectiveness, screening for diabetic retinopathy is a critical aspect in diabetes management. The aim of this study was to review the imaging modalities employed for retinal examination in diabetic retinopathy screening. Methods: The PubMed and Web of Science databases were the main sources used to investigate the medical literature. An extensive search was performed to identify relevant articles concerning "imaging ", "diabetic retinopathy " and "screening " up to 1 June 2021. Imaging techniques were divided into the following: (i) mydriatic fundus photography, (ii) non-mydriatic fundus photography, (iii) smartphone-based imaging, and (iv) ultrawide-field imaging. A meta-analysis was performed to analyze the performance and technical failure rate of each method. Results: The technical failure rates for mydriatic and non-mydriatic digital fundus photography, smartphone-based and ultrawide-field imaging were 3.4% (95% CI: 2.3-4.6%), 12.1% (95% CI: 5.4-18.7%), 5.3% (95% CI: 1.5-9.0%) and 2.2% (95% CI: 0.3-4.0%), respectively. The rate was significantly different between all analyzed techniques (p < 0.001), and the overall failure rate was 6.6% (4.9-8.3%; I-2 = 97.2%). The publication bias factor for smartphone-based imaging was significantly higher than for mydriatic digital fundus photography and non-mydriatic digital fundus photography (b = -8.61, b = -2.59 and b = -7.03, respectively; p < 0.001). Ultrawide-field imaging studies were excluded from the final sensitivity/specificity analysis, as the total number of patients included was too small. Conclusions: Regardless of the type of the device used, retinal photographs should be taken on eyes with dilated pupils, unless contraindicated, as this setting decreases the rate of ungradable images. Smartphone-based and ultrawide-field imaging may become potential alternative methods for optimized DR screening; however, there is not yet enough evidence for these techniques to displace mydriatic fundus photography.
引用
收藏
页数:27
相关论文
共 50 条
  • [41] Calcium dobesilate for diabetic retinopathy: a systematic review and meta-analysis
    XinYuan Zhang
    Wei Liu
    ShanShan Wu
    JingLong Jin
    WeiHong Li
    NingLi Wang
    Science China Life Sciences, 2015, 58 : 101 - 107
  • [42] Prevalence of diabetic retinopathy in Brazil: a systematic review with meta-analysis
    Chagas, Thiago Alves
    dos Reis, Mateus Augusto
    Leivas, Gabriel
    Santos, Lucas Porto
    Gossenheimer, Agnes Nogueira
    Melo, Gustavo Barreto
    Malerbi, Fernando Korn
    Schaan, Beatriz D.
    DIABETOLOGY & METABOLIC SYNDROME, 2023, 15 (01)
  • [43] Pregnancy and Diabetic Retinopathy: A Meta-Analysis
    Ha, B.
    Trang, J.
    Song, J.
    Wu, G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [44] Single-Field Non-Mydriatic Fundus Photography for Diabetic Retinopathy Screening: A Systematic Review and Meta-Analysis
    Hu, Jiying
    Chen, Ruiting
    Lu, Ying
    Dou, Xiaoyan
    Ye, Baikang
    Cai, Zhiming
    Pu, Zuhui
    Mou, Lisha
    OPHTHALMIC RESEARCH, 2019, 62 (02) : 61 - 67
  • [45] Automated Screening for Diabetic Retinopathy - A Systematic Review
    Norgaard, Mads Fonager
    Grauslund, Jakob
    OPHTHALMIC RESEARCH, 2018, 60 (01) : 9 - 17
  • [46] Systematic review and meta-analysis of diagnostic accuracy of detection of any level of diabetic retinopathy using digital retinal imaging
    Piyasena, Mapa Mudiyanselage Prabhath Nishantha
    Murthy, Gudlavalleti Venkata S.
    Yip, Jennifer L. Y.
    Gilbert, Clare
    Peto, Tunde
    Gordon, Iris
    Hewage, Suwin
    Kamalakannan, Sureshkumar
    SYSTEMATIC REVIEWS, 2018, 7
  • [47] Systematic review and meta-analysis of diagnostic accuracy of detection of any level of diabetic retinopathy using digital retinal imaging
    Mapa Mudiyanselage Prabhath Nishantha Piyasena
    Gudlavalleti Venkata S. Murthy
    Jennifer L. Y. Yip
    Clare Gilbert
    Tunde Peto
    Iris Gordon
    Suwin Hewage
    Sureshkumar Kamalakannan
    Systematic Reviews, 7
  • [48] Relationship between Diabetic Retinopathy and Systemic Neurodegenerative Diseases: A Systematic Review and Meta-analysis
    Pedersen, Helene E.
    Sandvik, Caroline H.
    Subhi, Yousif
    Grauslund, Jakob
    Pedersen, Frederik N.
    OPHTHALMOLOGY RETINA, 2022, 6 (02): : 139 - 152
  • [49] Association of VEGF Gene Polymorphisms with Susceptibility to Diabetic Retinopathy: A Systematic Review and Meta-Analysis
    Yang, Qianhui
    Zhang, Yan
    Zhang, Xiaomin
    Li, Xiaorong
    Liu, Juping
    HORMONE AND METABOLIC RESEARCH, 2020, 52 (05) : 264 - 279
  • [50] Effects of lipid-lowering agents on diabetic retinopathy: a Meta-analysis and systematic review
    Rui Shi
    Lei Zhao
    Feng Wang
    Fen Liu
    Zhuo Chen
    Rong Li
    Yang Liu
    Rong Lin
    International Journal of Ophthalmology, 2018, 11 (02) : 287 - 295