Imaging Modalities Employed in Diabetic Retinopathy Screening: A Review and Meta-Analysis

被引:14
|
作者
Kanclerz, Piotr [1 ,2 ]
Tuuminen, Raimo [2 ,3 ]
Khoramnia, Ramin [4 ]
机构
[1] Hygeia Clin, PL-80286 Gdansk, Poland
[2] Univ Helsinki, Fac Med, Helsinki Retina Res Grp, Helsinki 00014, Finland
[3] Kymenlaakso Cent Hosp, Eye Ctr, Kotka 48100, Finland
[4] Heidelberg Univ, Dept Ophthalmol, David J Apple Int Lab Ocular Pathol, D-69120 Heidelberg, Germany
关键词
diabetic retinopathy; fundus photography; mydriatic photography; screening; smartphone-based imaging; ultra-wide-field scanning laser ophthalmoscope; diabetic macular edema; OPTICAL COHERENCE TOMOGRAPHY; NONMYDRIATIC FUNDUS PHOTOGRAPHY; SCANNING LASER OPHTHALMOSCOPY; MACULAR EDEMA; SMARTPHONE OPHTHALMOSCOPY; RETINAL PHOTOGRAPHY; CHOROIDAL THICKNESS; VISUAL-ACUITY; RISK-FACTORS; SLIT-LAMP;
D O I
10.3390/diagnostics11101802
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Urbanization has caused dramatic changes in lifestyle, and these rapid transitions have led to an increased risk of noncommunicable diseases, such as type 2 diabetes. In terms of cost-effectiveness, screening for diabetic retinopathy is a critical aspect in diabetes management. The aim of this study was to review the imaging modalities employed for retinal examination in diabetic retinopathy screening. Methods: The PubMed and Web of Science databases were the main sources used to investigate the medical literature. An extensive search was performed to identify relevant articles concerning "imaging ", "diabetic retinopathy " and "screening " up to 1 June 2021. Imaging techniques were divided into the following: (i) mydriatic fundus photography, (ii) non-mydriatic fundus photography, (iii) smartphone-based imaging, and (iv) ultrawide-field imaging. A meta-analysis was performed to analyze the performance and technical failure rate of each method. Results: The technical failure rates for mydriatic and non-mydriatic digital fundus photography, smartphone-based and ultrawide-field imaging were 3.4% (95% CI: 2.3-4.6%), 12.1% (95% CI: 5.4-18.7%), 5.3% (95% CI: 1.5-9.0%) and 2.2% (95% CI: 0.3-4.0%), respectively. The rate was significantly different between all analyzed techniques (p < 0.001), and the overall failure rate was 6.6% (4.9-8.3%; I-2 = 97.2%). The publication bias factor for smartphone-based imaging was significantly higher than for mydriatic digital fundus photography and non-mydriatic digital fundus photography (b = -8.61, b = -2.59 and b = -7.03, respectively; p < 0.001). Ultrawide-field imaging studies were excluded from the final sensitivity/specificity analysis, as the total number of patients included was too small. Conclusions: Regardless of the type of the device used, retinal photographs should be taken on eyes with dilated pupils, unless contraindicated, as this setting decreases the rate of ungradable images. Smartphone-based and ultrawide-field imaging may become potential alternative methods for optimized DR screening; however, there is not yet enough evidence for these techniques to displace mydriatic fundus photography.
引用
收藏
页数:27
相关论文
共 50 条
  • [31] Systematic review and meta-analysis of the related factors for diabetic retinopathy
    Xuan, Jie
    Wang, Liqin
    Fan, Liqi
    Ji, Shuxing
    ANNALS OF PALLIATIVE MEDICINE, 2022, 11 (07) : 2368 - 2381
  • [32] Diabetic retinopathy and cognitive dysfunction: a systematic review and meta-analysis
    Mei Wu
    Fan Mei
    Kaiyan Hu
    Liyuan Feng
    Zhe Wang
    Qianqian Gao
    Fei Chen
    Li Zhao
    Xiaohui Li
    Bin Ma
    Acta Diabetologica, 2022, 59 : 443 - 459
  • [33] Gut microbiome in diabetic retinopathy: A systematic review and meta-analysis
    Zhao, Shuang
    Yan, Qi
    Xu, Wanjing
    Zhang, Juanmei
    MICROBIAL PATHOGENESIS, 2024, 189
  • [34] Calcium dobesilate for diabetic retinopathy: a systematic review and meta-analysis
    ZHANG XinYuan
    LIU Wei
    WU ShanShan
    JIN JingLong
    LI WeiHong
    Wang NingLi
    Science China(Life Sciences), 2015, 58 (01) : 101 - 107
  • [35] Telemedicine for detecting diabetic retinopathy: a systematic review and meta-analysis
    Shi, Lili
    Wu, Huiqun
    Dong, Jiancheng
    Jiang, Kui
    Lu, Xiting
    Shi, Jian
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (06) : 823 - 831
  • [36] Statins and/or fibrates for diabetic retinopathy: a systematic review and meta-analysis
    Vânia Mozetic
    Rafael Leite Pacheco
    Carolina de Oliveira Cruz Latorraca
    Rachel Riera
    Diabetology & Metabolic Syndrome, 11
  • [37] Vitreous biomarkers in diabetic retinopathy: A systematic review and meta-analysis
    McAuley, Annie K.
    Sanfilippo, Paul G.
    Hewitt, Alex W.
    Liang, Helena
    Lamoureux, Ecosse
    Wang, Jie Jin
    Connell, Paul P.
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2014, 28 (03) : 419 - 425
  • [38] Advances in Retinal Imaging and Applications in Diabetic Retinopathy Screening: A Review
    Beau J. Fenner
    Raymond L. M. Wong
    Wai-Ching Lam
    Gavin S. W. Tan
    Gemmy C. M. Cheung
    Ophthalmology and Therapy, 2018, 7 : 333 - 346
  • [39] Prevalence of diabetic retinopathy in Brazil: a systematic review with meta-analysis
    Thiago Alves Chagas
    Mateus Augusto dos Reis
    Gabriel Leivas
    Lucas Porto Santos
    Agnes Nogueira Gossenheimer
    Gustavo Barreto Melo
    Fernando Korn Malerbi
    Beatriz D. Schaan
    Diabetology & Metabolic Syndrome, 15
  • [40] Prevalence of diabetic retinopathy in Iran: a systematic review and Meta-analysis
    Saman Maroufizadeh
    Amir Almasi-Hashiani
    Mostafa Hosseini
    Mahdi Sepidarkish
    Reza Omani Samani
    International Journal of Ophthalmology, 2017, (05) : 782 - 789