Imaging Modalities Employed in Diabetic Retinopathy Screening: A Review and Meta-Analysis

被引:14
|
作者
Kanclerz, Piotr [1 ,2 ]
Tuuminen, Raimo [2 ,3 ]
Khoramnia, Ramin [4 ]
机构
[1] Hygeia Clin, PL-80286 Gdansk, Poland
[2] Univ Helsinki, Fac Med, Helsinki Retina Res Grp, Helsinki 00014, Finland
[3] Kymenlaakso Cent Hosp, Eye Ctr, Kotka 48100, Finland
[4] Heidelberg Univ, Dept Ophthalmol, David J Apple Int Lab Ocular Pathol, D-69120 Heidelberg, Germany
关键词
diabetic retinopathy; fundus photography; mydriatic photography; screening; smartphone-based imaging; ultra-wide-field scanning laser ophthalmoscope; diabetic macular edema; OPTICAL COHERENCE TOMOGRAPHY; NONMYDRIATIC FUNDUS PHOTOGRAPHY; SCANNING LASER OPHTHALMOSCOPY; MACULAR EDEMA; SMARTPHONE OPHTHALMOSCOPY; RETINAL PHOTOGRAPHY; CHOROIDAL THICKNESS; VISUAL-ACUITY; RISK-FACTORS; SLIT-LAMP;
D O I
10.3390/diagnostics11101802
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Urbanization has caused dramatic changes in lifestyle, and these rapid transitions have led to an increased risk of noncommunicable diseases, such as type 2 diabetes. In terms of cost-effectiveness, screening for diabetic retinopathy is a critical aspect in diabetes management. The aim of this study was to review the imaging modalities employed for retinal examination in diabetic retinopathy screening. Methods: The PubMed and Web of Science databases were the main sources used to investigate the medical literature. An extensive search was performed to identify relevant articles concerning "imaging ", "diabetic retinopathy " and "screening " up to 1 June 2021. Imaging techniques were divided into the following: (i) mydriatic fundus photography, (ii) non-mydriatic fundus photography, (iii) smartphone-based imaging, and (iv) ultrawide-field imaging. A meta-analysis was performed to analyze the performance and technical failure rate of each method. Results: The technical failure rates for mydriatic and non-mydriatic digital fundus photography, smartphone-based and ultrawide-field imaging were 3.4% (95% CI: 2.3-4.6%), 12.1% (95% CI: 5.4-18.7%), 5.3% (95% CI: 1.5-9.0%) and 2.2% (95% CI: 0.3-4.0%), respectively. The rate was significantly different between all analyzed techniques (p < 0.001), and the overall failure rate was 6.6% (4.9-8.3%; I-2 = 97.2%). The publication bias factor for smartphone-based imaging was significantly higher than for mydriatic digital fundus photography and non-mydriatic digital fundus photography (b = -8.61, b = -2.59 and b = -7.03, respectively; p < 0.001). Ultrawide-field imaging studies were excluded from the final sensitivity/specificity analysis, as the total number of patients included was too small. Conclusions: Regardless of the type of the device used, retinal photographs should be taken on eyes with dilated pupils, unless contraindicated, as this setting decreases the rate of ungradable images. Smartphone-based and ultrawide-field imaging may become potential alternative methods for optimized DR screening; however, there is not yet enough evidence for these techniques to displace mydriatic fundus photography.
引用
收藏
页数:27
相关论文
共 50 条
  • [1] Advances in Retinal Imaging and Applications in Diabetic Retinopathy Screening: A Review
    Fenner, Beau J.
    Wong, Raymond L. M.
    Lam, Wai-Ching
    Tan, Gavin S. W.
    Cheung, Gemmy C. M.
    OPHTHALMOLOGY AND THERAPY, 2018, 7 (02) : 333 - 346
  • [2] Comparison of Photographic Screening Methods for Diabetic Retinopathy - A Meta-analysis
    Yan, William
    McGuinness, Myra
    Chakrabarti, Rahul
    Fotis, Kathy
    Finger, Robert P.
    OPHTHALMIC EPIDEMIOLOGY, 2023, 30 (03) : 221 - 229
  • [3] The efficacy of artificial intelligence in diabetic retinopathy screening: a systematic review and meta-analysis
    Abdullah S. Alqahtani
    Wasan M. Alshareef
    Hanan T. Aljadani
    Wesal O. Hawsawi
    Marya H. Shaheen
    International Journal of Retina and Vitreous, 11 (1)
  • [4] Association of Diabetic Retinopathy With Stroke: A Systematic Review and Meta-Analysis
    Hu, Kaiyan
    Jiang, Mengyao
    Zhou, Qi
    Zeng, Weiting
    Lan, Xuhong
    Gao, Qianqian
    Mei, Fan
    Zhao, Li
    Chen, Fei
    Wu, Anhu
    Tao, Gongcai
    Mou, Chenghua
    Ma, Bin
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [5] Myopia and diabetic retinopathy: A systematic review and meta-analysis
    Wang, Xiang
    Tang, Luosheng
    Gao, Ling
    Yang, Yujia
    Cao, Dan
    Li, Yunping
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 111 : 1 - 9
  • [6] Relationship between dyslipidemia and diabetic retinopathy A systematic review and meta-analysis
    Zhou, Yue
    Wang, Changyun
    Shi, Ke
    Yin, Xiaolong
    MEDICINE, 2018, 97 (36)
  • [7] Screening of Diabetic Retinopathy Using Teleophthalmology to Complement Human Resources for Eye Health: A Systematic Review and Meta-Analysis
    Zikhali, Thembile
    Kalinda, Chester
    Xulu-Kasaba, Zamadonda Nokuthula
    CLINICS AND PRACTICE, 2022, 12 (04) : 457 - 467
  • [8] Screening for Presence or Absence of Diabetic Retinopathy: A Meta-analysis
    Bragge, Peter
    Gruen, Russell L.
    Chau, Marisa
    Forbes, Andrew
    Taylor, Hugh R.
    ARCHIVES OF OPHTHALMOLOGY, 2011, 129 (04) : 435 - 444
  • [9] Comparison of different methods of retinal imaging for the screening of diabetic retinopathy: a systematic review
    Karason, Kolbeinn Tumi
    Vo, Diana
    Grauslund, Jakob
    Rasmussen, Malin Lundberg
    ACTA OPHTHALMOLOGICA, 2022, 100 (02) : 127 - 135
  • [10] Statins and/or fibrates for diabetic retinopathy: a systematic review and meta-analysis
    Mozetic, Vania
    Pacheco, Rafael Leite
    Cruz Latorraca, Carolina de Oliveira
    Riera, Rachel
    DIABETOLOGY & METABOLIC SYNDROME, 2019, 11 (01)