Performance and usability of a new mobile application for measuring respiratory rate in young children with acute lower respiratory infections

被引:1
作者
Spurr, Rebecca [1 ]
Ng, Erin [2 ]
Onchiri, Frankline M. [2 ]
Rapha, Ben [3 ]
Nakatumba-Nabende, Joyce [3 ]
Rosenfeld, Margaret [1 ,2 ]
Najjingo, Irene [4 ]
Stout, James W. [1 ]
Nantanda, Rebecca [4 ]
Ellington, Laura E. [1 ,2 ]
机构
[1] Univ Washington, Sch Med, Dept Pediat, 4800 Sand Point Way NE,OC 7 720, Seattle, WA 98105 USA
[2] Seattle Childrens Hosp, Ctr Clin & Translat Res, Seattle Childrens Res Inst, Seattle, WA USA
[3] Makerere Univ, Sch Comp & Informat Technol, Dept Comp Sci, Kampala, Uganda
[4] Makerere Univ, Coll Hlth Sci, Lung Inst, Kampala, Uganda
关键词
child; mobile health; pneumonia; respiratory rate; LOW-RESOURCE SETTINGS; PNEUMONIA; VARIABILITY; ACCURACY; ARI;
D O I
10.1002/ppul.26125
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objectives Respiratory rate (RR) measurement is critical to diagnosing pneumonia in resource-constrained settings, but accurate RR measurement is challenging. The acute lower respiratory illness treatment and evaluation (ALRITE) mobile phone application (app), designed to help healthcare workers (HCWs) manage pediatric respiratory illnesses, includes a semiautomated RR counter. This study aimed to evaluate the accuracy and usability of the ALRITE RR counter and a commercially available RR counter app, RRate, with a reference standard. Methods This was a cross-sectional observational study of HCWs. Participants used both apps to measure the RR of pediatric patients from standardized videos. The reference standard was determined by consensus of a manual 1-min count by two providers. We assessed agreement using Spearman's rank correlation coefficient and constructed Bland-Altman plots to determine bias and limits of agreement. Participants completed a usability survey. Results Thirty-nine HCWs participated. The agreement between the apps and reference standard (Spearman's coefficient) was 0.83 (95% confidence interval [CI]: 0.78-0.87) for ALRITE and 0.62 (95% CI: 0.52-0.70) for RRate. ALRITE had a bias of -2 breaths/min (lower limit of agreement [LoA] -16 to +12) and RRate had a bias of -0.4 breaths/min (LoA -24 to +23) compared to the reference standard. Both apps had a poorer agreement at higher RRs. Based on usability survey responses, 95% found ALRITE easy to use. Conclusions The ALRITE RR counter has acceptable accuracy for counting RR in infants with respiratory distress, appears to be more accurate than a commercially available option, and was user-friendly. The ALRITE RR counter is a promising tool for meriting evaluation in real-world settings.
引用
收藏
页码:3009 / 3016
页数:8
相关论文
共 38 条
  • [1] User's guide to correlation coefficients
    Akoglu, Haldun
    [J]. TURKISH JOURNAL OF EMERGENCY MEDICINE, 2018, 18 (03): : 91 - 93
  • [2] Poor Agreement and Imprecision of Respiratory Rate Measurements in Children in a Low-Income Setting
    Amirav, Israel
    Masumbuko, Claude Kasereka
    Hawkes, Michael T.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 198 (11) : 1462 - 1463
  • [3] [Anonymous], 2019, AMERICANTHORACIC SOC, DOI [10.1164/ajrccm-conference.2019.199.1_MeetingAbstracts.A2242, DOI 10.1164/AJRCCM-CONFERENCE.2019.199.1_MEETINGABSTRACTS.A2242]
  • [4] Performance of community health workers managing malaria, pneumonia and diarrhoea under the community case management programme in central Uganda: a cross sectional study
    Bagonza, James
    Kibira, Simon P. S.
    Rutebemberwa, Elizeus
    [J]. MALARIA JOURNAL, 2014, 13
  • [5] Performance of Four Respiratory Rate Counters to Support Community Health Workers to Detect the Symptoms of Pneumonia in Children in Low Resource Settings: A Prospective, Multicentre, Hospital-Based, Single-Blinded, Comparative Trial
    Baker, Kevin
    Alfven, Tobias
    Mucunguzi, Akasiima
    Wharton-Smith, Alexandra
    Dantzer, Emily
    Habte, Tedila
    Matata, Lena
    Nanyumba, Diana
    Okwir, Morris
    Posada, Monica
    Sebsibe, Anteneh
    Nicholson, Jill
    Marasciulo, Madeleine
    Izadnegahdar, Rasa
    Petzold, Max
    Kallander, Karin
    [J]. ECLINICALMEDICINE, 2019, 12 : 20 - 30
  • [6] Baker Kevin, 2018, JMIR Res Protoc, V7, pe10191, DOI 10.2196/10191
  • [7] An empirical evaluation of the System Usability Scale
    Bangor, Aaron
    Kortum, Philip T.
    Miller, James T.
    [J]. INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2008, 24 (06) : 574 - 594
  • [8] Can simple mobile phone applications provide reliable counts of respiratory rates in sick infants and children? An initial evaluation of three new applications
    Black, James
    Gerdtz, Marie
    Nicholson, Pat
    Crellin, Dianne
    Browning, Laura
    Simpson, Julie
    Bell, Lauren
    Santamaria, Nick
    [J]. INTERNATIONAL JOURNAL OF NURSING STUDIES, 2015, 52 (05) : 963 - 969
  • [9] The community case management of pneumonia in Africa: a review of the evidence
    Druetz, Thomas
    Siekmans, Kendra
    Goossens, Sylvie
    Ridde, Valery
    Haddad, Slim
    [J]. HEALTH POLICY AND PLANNING, 2015, 30 (02) : 253 - 266
  • [10] Health workers' perspectives of a mobile health tool to improve diagnosis and management of paediatric acute respiratory illnesses in Uganda: a qualitative study
    Ellington, Laura Elizabeth
    Najjingo, Irene
    Rosenfeld, Margaret
    Stout, James W.
    Farquhar, Stephanie A.
    Vashistha, Aditya
    Nekesa, Bridget
    Namiya, Zaituni
    Kruse, Agatha J.
    Anderson, Richard
    Nantanda, Rebecca
    [J]. BMJ OPEN, 2021, 11 (07):