Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor

被引:29
作者
Nusselt, T. [1 ]
Freche, S. [1 ]
Klinger, H. -M. [1 ]
Baums, M. H. [1 ]
机构
[1] Univ Gottingen, Dept Orthopaed Surg, Med Ctr UMG, D-37099 Gottingen, Germany
关键词
Foreign body granuloma; Bioabsorbable; Suture anchor; Shoulder; Rotator cuff tear; L-LACTIC ACID; INTERFERENCE SCREW; FIXATION; OSTEOLYSIS; SHOULDER; STABILIZATION; DEGRADATION; SURGERY; TACKS;
D O I
10.1007/s00402-010-1125-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Biodegradable implants lead to problems such as cyst formation, soft-tissue inflammation, loose implant fragments or local osteolysis. This report represents the first published case of an intraosseous foreign body granuloma in the humeral head after arthroscopic rotator cuff tear fixation with a poly-l-lactide (PLLA) suture anchor. A 48-year-old female patient presented with pain in her right shoulder. A refixation of her right supraspinatus tendon with a biodegradable suture anchor was performed 11 months ago at an external hospital. Laboratory tests showed normal values for C-reactive protein, leukocytes and the erythrocyte sedimentation rate. No signs of infection or instability were noted. The visual analogue scale (VAS) was 8, the simple shoulder test (SST) was 4 and the American shoulder and elbow surgeons score (ASES) was 44. Plain radiographs showed high lucency in the area of the tuberculum majus. MRI showed an intra- and extraosseous mass surrounded by fluid in this area. Surgical care involved arthroscopic debridement and removal of the suture anchor. Histological examination revealed a foreign body granuloma. At the 18-month follow-up the patient was nearly pain-free. The VAS was 2, SST was 10 and ASES was 88. Foreign body granulomas are a well known but rarely described complication that arises after the use of biodegradable suture anchors in shoulder surgery. Every patient presenting with shoulder pain after usage of a biodegradable fixation material should be evaluated closely. Orthopaedic surgeons should be aware of the possibility of delayed foreign body reactions, especially after using PLLA anchors.
引用
收藏
页码:1037 / 1040
页数:4
相关论文
共 28 条
[1]   Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors - A report of four cases [J].
Athwal, George S. ;
Shridharani, Shyam M. ;
O'Driscoll, Shawn W. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (08) :1840-1845
[2]   Arthroscopic Bankart reconstruction with a bioabsorbable anchor [J].
Barber, FA ;
Snyder, SJ ;
Abrams, JS ;
Fanelli, GC ;
Savoie, FH .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (06) :535-538
[3]   A new bioabsorbable interference screw: Preliminary results of a prospective, multicenter, randomized clinical trial [J].
Benedetto, KP ;
Fellinger, M ;
Lim, TE ;
Passler, JM ;
Schoen, JL ;
Willems, WJ .
ARTHROSCOPY, 2000, 16 (01) :41-48
[4]   LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[5]   DEGRADATION AND TISSUE REPLACEMENT OF AN ABSORBABLE POLYGLYCOLIDE SCREW IN THE FIXATION OF RABBIT FEMORAL OSTEOTOMIES [J].
BOSTMAN, O ;
PAIVARINTA, U ;
PARTIO, E ;
VASENIUS, J ;
MANNINEN, M ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1021-1031
[6]   Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw -: A case report [J].
Böstman, OM ;
Pihlajamaki, HK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (12) :1791-1794
[7]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[8]  
Böstman OM, 2000, CLIN ORTHOP RELAT R, P216
[9]  
BURKHART SS, 2005, AM J SPORTS MED, V33, P11
[10]   Poly-L-lactic acid tack synovitis after arthroscopic stabilization of the shoulder [J].
Freehill, MQ ;
Harms, DJ ;
Huber, SM ;
Atlihan, D ;
Buss, DD .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (05) :643-647