Biomechanical comparison of cemented versus non-cemented anterior screw fixation in type II odontoid fractures in the elderly: a cadaveric study

被引:6
作者
Rehousek, Petr [1 ,2 ]
Jenner, Edward [1 ]
Holton, James [1 ]
Czyz, Marcin [1 ]
Capek, Lukas [3 ]
Henys, Petr [3 ]
Kulvajtova, Marketa [2 ]
Krbec, Martin [2 ]
Skala-Rosenbaum, Jiri [2 ]
机构
[1] Royal Orthopaed Hosp, Bristol Rd South, Birmingham B32 1AP, W Midlands, England
[2] Charles Univ Prague, Fac Med 3, Ruska 2411-87,10 Vinohrady, Prague 10000, Czech Republic
[3] Tech Univ Liberec, Studentska 1402-2, Liberec 46117, Czech Republic
关键词
Anterior screw fixation; Biomechanics; Cadaveric study; Cement augmentation; implant failure; Odontoid process fracture; Osteoporosis; BONE-MINERAL DENSITY; LUMBAR VERTEBRAE; OUTCOMES;
D O I
10.1016/j.spinee.2018.05.019
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Odontoid process fractures are the most common injuries of the cervical spine in the elderly. Anterior screw stabilization of type II odontoid process fractures improves survival and function in these patients but may be complicated by failure of fixation. PURPOSE: The present study aimed to determine whether cement augmentation of a standard anterior screw provides biomechanically superior fixation of type II odontoid fractures in comparison with a non-cemented standard screw. STUDY DESIGN: Twenty human cadaveric C2 vertebrae from elderly donors (mean age 83 years) were obtained. METHODS: Anderson and D'Alonzo type Ha odontoid fracture was created by transverse osteotomy, and fluoroscopy-guided anterior screw fixation was performed. The specimens were divided into two matched groups. The cemented group (n=10) had radiopaque high viscosity polymethylmethacrylate cement injected via Jamshidi needle into the base of the odontoid process. The other group was not augmented. A V-shaped punch was used for loading the odontoid in an anteroposterior direction until failure. The failure state was defined as screw cutout or 5% force decrease. Mean failure load and bending stiffness were calculated. RESULTS: The mean failure load for the cemented group was 352 +/- 12 N compared with 168 +/- 23 N for the non-cemented group (p<.001). The mean initial stiffness of the non-cemented group was 153 +/- 19 N/mm compared with 195 +/- 29 N/mm for the cemented group (p<.001) CONCLUSIONS: Cement augmentation of an anterior standard screw fixation of type II odontoid process fractures in elderly patients significantly increased load to failure under anteroposterior load in comparison with non-augmented fixation. This may be a valuable technique to reduce failure of fixation. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:1888 / 1895
页数:8
相关论文
共 30 条
  • [1] Odontoid fractures: high complication rate associated with anterior screw fixation in the elderly
    Andersson, S
    Rodrigues, M
    Olerud, C
    [J]. EUROPEAN SPINE JOURNAL, 2000, 9 (01) : 56 - 59
  • [2] Cervical spine bone mineral density as a function of vertebral level and anatomic location
    Anderst, William J.
    Thorhauer, Eric D.
    Lee, Joon Y.
    Donaldson, William F.
    Kang, James D.
    [J]. SPINE JOURNAL, 2011, 11 (07) : 659 - 667
  • [3] Brolin Karin, 2003, Inj Control Saf Promot, V10, P155, DOI 10.1076/icsp.10.3.155.14558
  • [4] The AOSpine North America Geriatric Odontoid Fracture Mortality Study A Retrospective Review of Mortality Outcomes for Operative Versus Nonoperative Treatment of 322 Patients With Long-Term Follow-Up
    Chapman, Jens
    Smith, Justin S.
    Kopjar, Branko
    Vaccaro, Alexander R.
    Arnold, Paul
    Shaffrey, Christopher I.
    Fehlings, Michael G.
    [J]. SPINE, 2013, 38 (13) : 1098 - 1104
  • [5] Vertebroplasty and kyphoplasty for cervical spine metastases: a systematic review and meta- analysis
    De la Garza-Ramos, Rafael
    Benvenutti-Regato, Mario
    Caro-Osorio, Enrique
    [J]. INTERNATIONAL JOURNAL OF SPINE SURGERY, 2016, 10
  • [6] Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis
    Du, Jerry Y.
    Aichmair, Alexander
    Kueper, Janina
    Wright, Timothy
    Lebl, Darren R.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (02) : 151 - 161
  • [7] One-Screw Fixation Provides Similar Stability to That of Two-Screw Fixation for Type II Dens Fractures
    Feng, Gang
    Wendlandt, Robert
    Spuck, Sebastian
    Schulz, Arndt P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (07) : 2021 - 2028
  • [8] PMMA-augmentation of incompletely cannulated pedicle screws: A cadaver study to determine the benefits in the osteoporotic spine
    Goost, H.
    Deborre, C.
    Wirtz, D. C.
    Burger, C.
    Prescher, A.
    Foelsch, C.
    Pflugmacher, R.
    Kabir, K.
    [J]. TECHNOLOGY AND HEALTH CARE, 2014, 22 (04) : 607 - 615
  • [9] Anterior screw fixation of type IIB odontoid fractures in octogenarians
    Henaux, P. L.
    Cueff, F.
    Diabira, S.
    Riffaud, L.
    Hamlat, A.
    Brassier, G.
    Morandi, X.
    [J]. EUROPEAN SPINE JOURNAL, 2012, 21 (02) : 335 - 339
  • [10] Rationale and design of the INNOVATE Trial: an international cooperative study on surgical versus conservative treatment for odontoid fractures in the elderly
    Huybregts, Jeroen G. J.
    Jacobs, Wilco C. H.
    Peul, Wilco C.
    Vleggeert-Lankamp, Carmen L. A.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2014, 15