Study on subsynchronous oscillation in D-PMSGs-based wind farm integrated to power system

被引:57
作者
Huang, Biyue [1 ]
Sun, Haishun [1 ]
Liu, Yuming [1 ]
Wang, Long [1 ]
Chen, Yahao [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
关键词
power system stability; wind power plants; permanent magnet generators; synchronous generators; AC motor drives; eigenvalues and eigenfunctions; subsynchronous oscillation; D-PMSG-based wind farm; SSO; direct-drive permanent magnetic synchronous generators-based wind farm; subsynchronous interaction; SSI; AC network; eigenvalue analysis; small-signal state-space model; electromagnetic transient simulation model; PMSG equivalent system; PSCAD; EMTDC; GENERATOR; STABILITY; SSR;
D O I
10.1049/iet-rpg.2018.5051
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In recent years, the subsynchronous oscillation (SSO), which occurs in direct-drive permanent magnetic synchronous generators (D-PMSGs)-based wind farm, has great impact on the stability of power system. The different parameters and operation conditions of D-PMSGs lead to the subsynchronous interaction (SSI) among D-PMSGs. What is more, the SSI will influence the SSO characteristics of the system of D-PMSGs-based wind farm integrated to AC network. Here, considering the difference of parameters or operation conditions among D-PMSGs in the wind farm, eigenvalue analysis, based on the small-signal state-space model of two aggregated D-PMSGs which are equivalent to wind farm, is carried out. Then the stability and the SSI between D-PMSGs of the equivalent system can be studied, and the dominant D-PMSG can be determined based on the participation factors. Lastly, the detailed electromagnetic transient simulation model of D-PMSGs equivalent system is built in PSCAD/EMTDC. The simulation is conducted to corroborate the eigenvalue analysis. The result shows that an obvious SSI exists between two aggregated D-PMSGs. Furthermore, the different SSO characteristics among D-PMSGs in the wind farm indicate the study of SSO problem based on an aggregated D-PMSGs model may leave out some useful information.
引用
收藏
页码:16 / 26
页数:11
相关论文
共 20 条
[1]  
[Anonymous], 2017, J ENG-NY
[2]   General Methodology for Analysis of Sub-Synchronous Interaction in Wind Power Plants [J].
Badrzadeh, Babak ;
Sahni, Mandhir ;
Zhou, Yi ;
Muthumuni, Dharshana ;
Gole, Aniruddha .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (02) :1858-1869
[3]   Study on response characteristics of grid-side converter controller of PMSG to sub-synchronous frequency component [J].
Bi, Tianshu ;
Li, Jingyi ;
Zhang, Peng ;
Mitchell-Colgan, Elliot ;
Xiao, Shiwu .
IET RENEWABLE POWER GENERATION, 2017, 11 (07) :966-972
[4]   Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters [J].
Cespedes, Mauricio ;
Sun, Jian .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1254-1261
[5]  
Chouket M., 2015, 2015 IEEE 12 INT MUL, P1
[6]  
Feltes J. W., 2011, P IEEE POW EN SOC GE, P1
[7]   Small-signal stability of wind power system with full-load converter interfaced wind turbines [J].
Knuppel, T. ;
Nielsen, J. N. ;
Jensen, K. H. ;
Dixon, A. ;
Ostergaard, J. .
IET RENEWABLE POWER GENERATION, 2012, 6 (02) :79-91
[8]   An Oscillatory Stability Criterion Based on the Unified dq-Frame Impedance Network Model for Power Systems With High-Penetration Renewables [J].
Liu, Huakun ;
Xie, Xiaorong ;
Liu, Wei .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (03) :3472-3485
[9]   Subsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks [J].
Liu, Huakun ;
Xie, Xiaorong ;
He, Jingbo ;
Xu, Tao ;
Yu, Zhao ;
Wang, Chao ;
Zhang, Chuanyu .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (06) :4708-4720
[10]   Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network [J].
Miao, Zhixin .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (04) :984-991