Endovascular repair of Stanford B aortic dissection using two stent grafts with different sizes

被引:39
作者
Huang, Xiaoyong [1 ]
Huang, Lianjun [1 ]
Sun, Lizhong [2 ]
Xu, Shangdong [2 ]
Xue, Yuguo [1 ]
Zeng, Qinglong [1 ]
Guo, Xi [1 ]
Peng, Mingliang [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Intervent, Beijing 100029, Peoples R China
[2] Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiac Surg, Beijing 100029, Peoples R China
关键词
MANAGEMENT; PLACEMENT; DIAMETERS; OUTCOMES;
D O I
10.1016/j.jvs.2015.02.022
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The objective of this study was to introduce a novel strategy for thoracic endovascular aortic repair of Stanford B aortic dissection using two-stent graft implantation (TSI), in which the proximal stent and distal stent with different sizes are sequentially deployed, and to summarize our experience with this technique. Methods: A retrospective study was conducted of 72 consecutive patients (61 men; mean age, 55 +/- 7 years; range, 41-67 years) with Stanford type B aortic dissection who underwent TSI treatment between January 2012 and May 2013. Among all patients, 43 (59.7%) involved the infrarenal aorta and 29 (40.3%) involved the whole thoracic and abdominal aorta; mean aortic involvement length was 226 +/- 13 mm (range, 182-312 mm). Eight cases were for acute dissection (within 2 weeks from onset of symptoms), 11 cases were for chronic dissection (>3 months after initial dissection), and 53 cases were for subacute dissection (between 2 weeks and 3 months). Twenty-two cases (30.6%) were uncomplicated type and 50 cases (69.4%) were complicated type. Follow-up was performed postoperatively at 1 month, 6 months, and yearly thereafter. Technique success, aorta morphology, and procedure-related complications were evaluated. Results: Technical success was achieved in 100%; 72 pairs of stent grafts (144 thoracic stent grafts) and 10 left subclavian artery chimney stents were used. The mean aortic length coverage by the stent grafts was 197.6 +/- 20.3 mm, and mean taper diameter span was 7.5 +/- 1.8 mm. All patients were followed up from 6 to 16 months (mean, 10 +/- 4 months); 95.8% (69 of 72) had a thrombosed false lumen in the aortic coverage, and the true lumen expanded on average 57% +/- 11% (23%-100%). No significant changes were found in aortic diameters of the proximal and distal ends of the two stent grafts and the angles between centerlines of the distal end of the stent and the aorta during follow-up. Procedure-related complications included transient paraplegia (coverage of the left subclavian artery without revascularization and extensive coverage of aorta >220 mm) due to acute spinal cord ischemia (n = 1) and malapposition of the distal stent (primary tear closed, true lumen expansion led to oversize rate insufficient in distal stent diameter; n = 1). No death or malperfusion complications were observed during the perioperative period and follow-up. Conclusions: Short-term outcomes showed TSI to be a flexible and effective approach to accurately repair Stanford B aortic dissection that could potentially address the limitations of currently available stent grafts. Further prospective clinical studies are warranted to evaluate its long-term efficacy.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 19 条
  • [1] Systematic review of outcomes of combined proximal stent grafting with distal bare stenting for management of aortic dissection
    Canaud, Ludovic
    Patterson, Benjamin O.
    Peach, George
    Hinchliffe, Robert
    Loftus, Ian
    Thompson, Matt M.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (06) : 1431 - 1438
  • [2] Endovascular stent-graft placement for the treatment of acute aortic dissection
    Dake, MD
    Kato, N
    Mitchell, RS
    Semba, CP
    Razavi, MK
    Shimono, T
    Hirano, T
    Takeda, K
    Yada, I
    Miller, DC
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (20) : 1546 - 1552
  • [3] Retrograde Type A Aortic Dissection After Endovascular Stent Graft Placement for Treatment of Type B Dissection
    Dong, Zhi Hui
    Fu, Wei Guo
    Wang, Yu Qi
    Guo, Da Qiao
    Xu, Xin
    Ji, Yuan
    Chen, Bin
    Jiang, Jun Hao
    Yang, Jue
    Shi, Zhen Yu
    Zhu, Ting
    Shi, Yun
    [J]. CIRCULATION, 2009, 119 (05) : 735 - U133
  • [4] Extent of Aortic Coverage and Incidence of Spinal Cord Ischemia After Thoracic Endovascular Aneurysm Repair
    Feezor, Robert J.
    Martin, Tomas D.
    Hess, Philip J., Jr.
    Daniels, Michael J.
    Beaver, Thomas M.
    Klodell, Charles T.
    Lee, W. Anthony
    [J]. ANNALS OF THORACIC SURGERY, 2008, 86 (06) : 1809 - 1814
  • [5] [黄连军 Huang Lianjun], 2004, [中华心血管病杂志, Chinese Journal of Cardiology], V32, P141
  • [6] Body-surface adjusted aortic reference diameters for improved identification of patients with thoracic aortic aneurysms: Results from the population-based Heinz Nixdorf Recall study
    Kaelsch, Hagen
    Lehmann, Nils
    Moehlenkamp, Stefan
    Becker, Anna
    Moebus, Susanne
    Schmermund, Axel
    Stang, Andreas
    Mahabadi, Amir A.
    Mann, Klaus
    Joeckel, Karl-Heinz
    Erbel, Raimund
    Eggebrecht, Holger
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 (01) : 72 - 78
  • [7] Midterm results of stent-graft repair of acute and chronic aortic dissection with descending tear: The complication-specific approach
    Kato, N
    Shimono, T
    Hirano, T
    Suzuki, T
    Ishida, M
    Sakuma, H
    Yada, I
    Takeda, K
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (02) : 306 - 312
  • [8] Aortic remodeling after endovascular treatment of complicated type B aortic dissection with the use of a composite device design
    Lombardi, Joseph V.
    Cambria, Richard P.
    Nienaber, Christoph A.
    Chiesa, Roberto
    Mossop, Peter
    Haulon, Stephan
    Zhou, Qing
    Jia, Feiyi
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) : 1544 - 1554
  • [9] Prospective multicenter clinical trial (STABLE) on the endovascular treatment of complicated type B aortic dissection using a composite device design
    Lombardi, Joseph V.
    Cambria, Richard P.
    Nienaber, Christoph A.
    Chiesa, Roberto
    Teebken, Omke
    Lee, Anthony
    Mossop, Peter
    Bharadwaj, Priya
    [J]. JOURNAL OF VASCULAR SURGERY, 2012, 55 (03) : 629 - U319
  • [10] Serious complications following endovascular thoracic aortic stent-graft repair for type B dissection
    Neuhauser, Beate
    Greiner, Andreas
    Jaschke, Werner
    Chemelli, Andreas
    Fraedrich, Gustav
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (01) : 58 - 63