Novel sensitive amperometric hydrogen peroxide sensor using layered hierarchical porous α-MoO3 and GO modified glass carbon electrode

被引:50
|
作者
Li, Bo [1 ,2 ]
Song, Hai-Yan [1 ]
Deng, Zhao-Peng [1 ]
Huo, Li-Hua [1 ]
Gao, Shan [1 ]
机构
[1] Heilongjiang Univ, Sch Chem & Mat Sci, Key Lab Funct Inorgan Mat Chem, Minist Educ, Harbin 150080, Heilongjiang, Peoples R China
[2] Heihe Univ, Coll Sci, Heihe 164300, Peoples R China
基金
中国国家自然科学基金;
关键词
alpha-MoO3; Hierarchical porous structure; Graphene oxide; Electrochemical sensor; Hydrogen peroxide; FREE ELECTROCHEMICAL IMMUNOSENSOR; REDUCED GRAPHENE OXIDE; MOLYBDENUM TRIOXIDE; MESOPOROUS CARBON; RAPID SYNTHESIS; H2O2; NANOPARTICLES; NANOCOMPOSITE; DEPOSITION; NANOFIBERS;
D O I
10.1016/j.snb.2019.03.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The nonenzymatic electrochemical H2O2 sensor based on molybdenum oxides has been rarely reported. In this work, a nonenzymatic electrode, hierarchical porous alpha-MoO3 and graphene oxide decorated glass carbon electrode (alpha-MoO3/GO/GCE) used for H2O2 electrochemical detection, is firstly fabricated by simple layer-by-layer assemble method, in which the alpha-MoO3 is derived by one-step pyrolysis of the regular organic-inorganic hybrid [(H2L)(2)(Mo8O26)](n) [HL = N-(pyridin-3-ylmethyl)pyridine-3-amine] single crystal precursor. The wedge-shaped morphology of the material is accumulated by micro-slices which comprise of nanosheets and small particles with average size of 25 nm. Meanwhile, different types of meso-and macro-pores with the size distributions of 4-6, 20-35 and 100-150 nm are observed, respectively. The alpha-MoO3/GO/GCE sensor based on the optimal ratio of 1:1 shows excellent electrocatalytic H2O2 property at room temperature. It displays the broad linear detection from 0.92 mu M to 2.46 mM and the high sensitivity is calculated to be 391.39 mu A mM(-1) cm(-2) with a low detection limit of 0.31 mu M (S/N = 3). The sensor can achieve 95% steady state current within 5 s and present well stability, reproducibility and anti-interference during H2O2 detection. Furthermore, the sensor is applied for the determination of H2O2 in human serum samples. The excellent performances of this sensor are related to the hierarchical porous structure of alpha-MoO3 and its synergistic effect with GO.
引用
收藏
页码:641 / 648
页数:8
相关论文
共 50 条
  • [21] Electrodepositing Ag nanodendrites on layered double hydroxides modified glassy carbon electrode: Novel hierarchical structure for hydrogen peroxide detection
    Yang, Zhe
    Tjiu, Weng Weei
    Fan, Wei
    Liu, Tianxi
    ELECTROCHIMICA ACTA, 2013, 90 : 400 - 407
  • [22] A sensitive nonenzymatic hydrogen peroxide sensor using cadmium oxide nanoparticles/multiwall carbon nanotube modified glassy carbon electrode
    Butwong, Nutthaya
    Zhou, Lin
    Ng-Eontae, Wittaya
    Burakham, Rodjana
    Moore, Eric
    Srijaranai, Supalax
    Luong, John H. T.
    Glennon, Jeremy D.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 717 : 41 - 46
  • [23] Phosphomolybdate-polypyrrole composite bulk-modified carbon paste electrode for a hydrogen peroxide amperometric sensor
    Wang, XL
    Zhang, H
    Wang, EB
    Han, ZB
    Hu, CW
    MATERIALS LETTERS, 2004, 58 (10) : 1661 - 1664
  • [24] A highly sensitive hydrogen peroxide amperometric sensor based on MnO2-modified vertically aligned multiwalled carbon nanotubes
    Xu, Bin
    Ye, Min-Ling
    Yu, Yu-Xiang
    Zhang, Wei-De
    ANALYTICA CHIMICA ACTA, 2010, 674 (01) : 20 - 26
  • [25] Direct electrochemistry of hemoglobin on graphene/Fe3O4 nanocomposite-modified glass carbon electrode and its sensitive detection for hydrogen peroxide
    Wang, Yuqiao
    Zhang, Huijun
    Yao, Dan
    Pu, Junjie
    Zhang, Yuan
    Gao, Xiaorui
    Sun, Yueming
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2013, 17 (03) : 881 - 887
  • [26] Fabrication of CaTiO3 modified glassy carbon electrode-based hydrogen peroxide sensor
    Ahmad, Khursheed
    Niyitanga, Theophile
    Pathak, Aarti
    Khan, Rais Ahmad
    Khan, Mohd Quasim
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2024, 21 (08) : 2147 - 2157
  • [27] A highly sensitive hydrogen peroxide sensor based on (Ag-Au NPs)/ poly[o-phenylenediamine] modified glassy carbon electrode
    Shamsipur, Mojtaba
    Karimi, Ziba
    Tabrizi, Mahmoud Amouzadeh
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 56 : 426 - 431
  • [28] Highly sensitive hydrogen peroxide sensor based on a glassy carbon electrode modified with platinum nanoparticles on carbon nanofiber heterostructures
    Yang, Yang
    Fu, Renzhong
    Yuan, Jianjun
    Wu, Shiyuan
    Zhang, Jialiang
    Wang, Haiying
    MICROCHIMICA ACTA, 2015, 182 (13-14) : 2241 - 2249
  • [29] Highly sensitive hydrogen peroxide sensor based on a glassy carbon electrode modified with platinum nanoparticles on carbon nanofiber heterostructures
    Yang Yang
    Renzhong Fu
    Jianjun Yuan
    Shiyuan Wu
    Jialiang Zhang
    Haiying Wang
    Microchimica Acta, 2015, 182 : 2241 - 2249
  • [30] An amperometric hydrogen peroxide chemical sensor based on graphene-Fe3O4 multilayer films modified ITO electrode
    Liu, Xuexia
    Zhu, Hui
    Yang, Xiurong
    TALANTA, 2011, 87 : 243 - 248