Novel sensitive amperometric hydrogen peroxide sensor using layered hierarchical porous α-MoO3 and GO modified glass carbon electrode

被引:50
|
作者
Li, Bo [1 ,2 ]
Song, Hai-Yan [1 ]
Deng, Zhao-Peng [1 ]
Huo, Li-Hua [1 ]
Gao, Shan [1 ]
机构
[1] Heilongjiang Univ, Sch Chem & Mat Sci, Key Lab Funct Inorgan Mat Chem, Minist Educ, Harbin 150080, Heilongjiang, Peoples R China
[2] Heihe Univ, Coll Sci, Heihe 164300, Peoples R China
基金
中国国家自然科学基金;
关键词
alpha-MoO3; Hierarchical porous structure; Graphene oxide; Electrochemical sensor; Hydrogen peroxide; FREE ELECTROCHEMICAL IMMUNOSENSOR; REDUCED GRAPHENE OXIDE; MOLYBDENUM TRIOXIDE; MESOPOROUS CARBON; RAPID SYNTHESIS; H2O2; NANOPARTICLES; NANOCOMPOSITE; DEPOSITION; NANOFIBERS;
D O I
10.1016/j.snb.2019.03.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The nonenzymatic electrochemical H2O2 sensor based on molybdenum oxides has been rarely reported. In this work, a nonenzymatic electrode, hierarchical porous alpha-MoO3 and graphene oxide decorated glass carbon electrode (alpha-MoO3/GO/GCE) used for H2O2 electrochemical detection, is firstly fabricated by simple layer-by-layer assemble method, in which the alpha-MoO3 is derived by one-step pyrolysis of the regular organic-inorganic hybrid [(H2L)(2)(Mo8O26)](n) [HL = N-(pyridin-3-ylmethyl)pyridine-3-amine] single crystal precursor. The wedge-shaped morphology of the material is accumulated by micro-slices which comprise of nanosheets and small particles with average size of 25 nm. Meanwhile, different types of meso-and macro-pores with the size distributions of 4-6, 20-35 and 100-150 nm are observed, respectively. The alpha-MoO3/GO/GCE sensor based on the optimal ratio of 1:1 shows excellent electrocatalytic H2O2 property at room temperature. It displays the broad linear detection from 0.92 mu M to 2.46 mM and the high sensitivity is calculated to be 391.39 mu A mM(-1) cm(-2) with a low detection limit of 0.31 mu M (S/N = 3). The sensor can achieve 95% steady state current within 5 s and present well stability, reproducibility and anti-interference during H2O2 detection. Furthermore, the sensor is applied for the determination of H2O2 in human serum samples. The excellent performances of this sensor are related to the hierarchical porous structure of alpha-MoO3 and its synergistic effect with GO.
引用
收藏
页码:641 / 648
页数:8
相关论文
共 50 条
  • [1] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jin, Jiayi
    Wu, Wenqin
    Min, Hui
    Wu, Huimin
    Wang, Shengfu
    Ding, Yu
    Yang, Shuijin
    MICROCHIMICA ACTA, 2017, 184 (05) : 1389 - 1396
  • [2] An Amperometric Sensitive Hydrogen Peroxide Sensor Based on a Silver Nanoparticle-Doped Polyimide-Modified Glassy Carbon Electrode
    Chen, Lin
    Wang, Yue
    Ban, Hao
    Yu, Simin
    Tao, Dongping
    Hu, Zhizhi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (11): : 10961 - 10972
  • [3] A sensitive amperometric hydrogen peroxide sensor based on thionin/EDTA/carbon nanotubes-chitosan composite film modified electrode
    Zhang, Keying
    Zhang, Li
    Xu, Jigui
    Wang, Cong
    Geng, Tao
    Wang, Hongyan
    Zhu, Jun
    MICROCHIMICA ACTA, 2010, 171 (1-2) : 139 - 144
  • [4] Carbon-black-doped Polyimide-modified Glassy Carbon Electrode for Sensitive Nonenzymatic Amperometric Determination of Hydrogen Peroxide
    Wang, Yue
    Chen, Lin
    Zhang, Yan
    Wang, Qingnan
    Ma, Ruidan
    Hasebe, Yasushi
    Zhang, Zhiqiang
    Hu, Zhizhi
    SENSORS AND MATERIALS, 2019, 31 (04) : 1191 - 1203
  • [5] Amperometric Sensing of Hydrogen Peroxide Using Graphene Oxide-Alizarin Modified Glassy Carbon Electrode
    Muhammet, Sinan Mithat
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):
  • [6] An Efficient Amperometric Sensor for Hydrogen Peroxide by Using a Carbon Paste Electrode Modified with Cobalt Impregnated Zeolite
    Norouzi, Banafsheh
    Moradian, Majid
    Malekan, Ali
    PORTUGALIAE ELECTROCHIMICA ACTA, 2015, 33 (02) : 111 - 124
  • [7] A novel nonenzymatic hydrogen peroxide amperometric sensor based on Pd@CeO2-NH2 nanocomposites modified glassy carbon electrode
    Guler, Muhammet
    Turkoglu, Vedat
    Kivrak, Arif
    Karahan, Fatih
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2018, 90 : 454 - 460
  • [8] A sensitive amperometric hydrogen peroxide sensor based on thionin/EDTA/carbon nanotubes—chitosan composite film modified electrode
    Keying Zhang
    Li Zhang
    Jigui Xu
    Cong Wang
    Tao Geng
    Hongyan Wang
    Jun Zhu
    Microchimica Acta, 2010, 171 : 139 - 144
  • [9] TiO2/MWCNT/Nafion-Modified Glassy Carbon Electrode as a Sensitive Voltammetric Sensor for the Determination of Hydrogen Peroxide
    de Oliveira, Rafael Henrique
    Goncalves, Daniel A.
    dos Reis, Diogo Duarte
    SENSORS, 2023, 23 (18)
  • [10] SnO2QDs Deposited on GO/PPy-Modified Glassy Carbon Electrode for Efficient Electrochemical Hydrogen Peroxide Sensor
    Molahalli, Vandana
    Sharma, Aman
    Shetty, Apoorva
    Hegde, Gurumurthy
    BIOSENSORS-BASEL, 2022, 12 (11):