At-line mid infrared spectroscopy for monitoring downstream processing unit operations

被引:32
作者
Capito, Florian [1 ]
Skudas, Romas [2 ]
Kolmar, Harald [1 ]
Hunzinger, Christian [2 ]
机构
[1] Tech Univ Darmstadt, Inst Organ Chem & Biochem, Darmstadt, Germany
[2] Merck KGaA, Darmstadt, Germany
关键词
Analytics; Mid infrared spectroscopy; Monitoring; QUANTIFICATION; ANTIBODY; PROTEINS; STABILITY; STORAGE;
D O I
10.1016/j.procbio.2015.03.005
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
At-line mid infrared spectroscopy (FT-MIR) was used for monitoring monoclonal antibody (mAb) titer, host cell protein levels and antibody aggregate amount in samples, originating from different downstream processing unit operations, performed during technical laboratory scale development runs. Antibody aggregate quantification was possible down to 1% [w/w], while host cell protein levels could be monitored down to 700 ng ml(-1). Antibody titer could be determined with high accuracy for samples >0.7 g L-1, with the possibility to further increase sensitivity when using samples with highly similar matrix. Comparing these results to relevant levels during downstream processing, the most promising applicability of FT-MIR is within target protein (mAb) monitoring, while HCP monitoring following intermediate and polishing chromatography steps is currently not a well-suited application. FT-MIR for aggregate monitoring is more suitable for steps resulting in higher aggregate levels such as pH stress and shear stress-related purification steps. Additionally, FT-MIR might be considered for monitoring of samples with higher HCP and aggregate amount profiles, which can occur during initial purification steps and when using alternative purification methods such as precipitation. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:997 / 1005
页数:9
相关论文
共 24 条
[1]  
Andya JD, 2003, AAPS PHARMSCI, V5
[2]   Effect of moisture on the stability of a lyophilized humanized monoclonal antibody formulation [J].
Breen, ED ;
Curley, JG ;
Overcashier, DE ;
Hsu, CC ;
Shire, SJ .
PHARMACEUTICAL RESEARCH, 2001, 18 (09) :1345-1353
[3]   A tool for selective inline quantification of co-eluting proteins in chromatography using spectral analysis and partial least squares regression [J].
Brestrich, Nina ;
Briskot, Till ;
Osberghaus, Anna ;
Hubbuch, Juergen .
BIOTECHNOLOGY AND BIOENGINEERING, 2014, 111 (07) :1365-1373
[4]  
Capito F, 2014, INFRARED SPECTROSCOP, P205
[5]   Mid-infrared spectroscopy-based antibody aggregate quantification in cell culture fluids [J].
Capito, Florian ;
Skudas, Romas ;
Kolmar, Harald ;
Hunzinger, Christian .
BIOTECHNOLOGY JOURNAL, 2013, 8 (08) :912-U48
[6]   Matrix effects during monitoring of antibody and host cell proteins using attenuated total reflection spectroscopy [J].
Capito, Florian ;
Skudas, Romas ;
Stanislawski, Bernd ;
Kolmar, Harald .
BIOTECHNOLOGY PROGRESS, 2013, 29 (01) :265-274
[7]   Host cell protein quantification by fourier transform mid infrared spectroscopy (FT-MIR) [J].
Capito, Florian ;
Skudas, Romas ;
Kolmar, Harald ;
Stanislawski, Bernd .
BIOTECHNOLOGY AND BIOENGINEERING, 2013, 110 (01) :252-259
[8]   Theory and application of near infrared reflectance spectroscopy in determination of food quality [J].
Cen, Haiyan ;
He, Yong .
TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2007, 18 (02) :72-83
[9]  
Champion K., 2005, BioProcess International, V5, P52
[10]   Industrial choices for protein production by large-scale cell culture [J].
Chu, L ;
Robinson, DK .
CURRENT OPINION IN BIOTECHNOLOGY, 2001, 12 (02) :180-187