Comparison of Optical Aberrations and Contrast Sensitivity Between Aspheric and Spherical Intraocular Lenses

被引:19
作者
Morales, Eduardo L. [1 ]
Rocha, Karolinne M. [2 ]
Chalita, Maria Regina [1 ]
Nose, Walton [3 ]
Avila, Marcos P. [4 ]
机构
[1] Univ Brasilia, BR-70670111 Brasilia, DF, Brazil
[2] Cleveland Clin Fdn, Cole Eye Inst, Cleveland, OH 44195 USA
[3] Univ Fed Sao Paulo, Sao Paulo, Brazil
[4] Univ Fed Goias, Goiania, Go, Brazil
关键词
VISUAL FUNCTION; PERFORMANCE; CATARACT; QUALITY; DESIGN; EYES;
D O I
10.3928/1081597X-20110708-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare visual acuity, aberrometry, and contrast sensitivity in patients who had a spherical intraocular lens (IOL) (SoFlex SE, Bausch & Lomb) implanted in one eye and an aspheric IOL (SofPort AO, Bausch & Lomb) implanted in the fellow eye during uncomplicated cataract surgery. METHODS: A prospective, multicenter, double-blind study was performed. Forty patients (80 eyes) underwent bilateral phacoemulsification with implantation of a spherical IOL in one eye and an aspheric IOL in the fellow eye. Postoperatively, visual acuity, aberrometry, and contrast sensitivity tests were performed. Statistical analyses were performed using Student t and Wilcoxon tests, and mixed effects were used for each contrast condition situation. RESULTS: Thirty-nine patients (30 women, 9 men; 78 eyes) with a mean age of 69.3 +/- 6.17 years (range: 51 to 82 years) completed the study. No statistical differences were found regarding visual acuity among eyes. Lower levels of higher order aberrations were achieved in the aspheric group. No statistical difference between groups under photopic conditions was noted. In low spatial frequencies, better performance was observed with the aspheric IOL under mesopic conditions. In high spatial frequencies, the spherical IOL produced better quality of vision. Comparing mesopic conditions with glare, visual performance was statistically better using the aspheric IOL. CONCLUSIONS: Cataract surgery results cannot be measured by means of visual acuity alone. Quality of vision must be considered, and implantation of IOLs with low levels of spherical aberrations and better contrast sensitivity are preferred. In this study, the aspheric IOL demonstrated better visual function, especially at night, when compared with spherical IOLs. [J Refract Surg. 2011;27(10):723-728.] doi:10.3928/1081597X-20110708-02
引用
收藏
页码:723 / 728
页数:6
相关论文
共 16 条
[1]   A comparison of visual performance between a rigid PMMA and a foldable acrylic intraocular lens [J].
Afsar, AJ ;
Patel, S ;
Woods, RL ;
Wykes, W .
EYE, 1999, 13 (3) :329-335
[2]   Optical performance of 3 intraocular lens designs in the presence of decentration [J].
Altmann, GE ;
Nichamin, LD ;
Lane, SS ;
Pepose, JS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (03) :574-585
[3]  
Bellucci R, 2004, J REFRACT SURG, V20, P297
[4]   Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study [J].
Bellucci, R ;
Scialdone, A ;
Buratto, L ;
Morselli, S ;
Chierego, C ;
Criscuoli, A ;
Moretti, G ;
Piers, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) :712-717
[5]   COMPARING CLINICAL-TESTS OF VISUAL FUNCTION IN CATARACT WITH THE PATIENTS PERCEIVED VISUAL DISABILITY [J].
ELLIOTT, DB ;
HURST, MA ;
WEATHERILL, J .
EYE, 1990, 4 :712-717
[6]  
Guirao A, 2002, ARCH OPHTHALMOL-CHIC, V120, P1143
[7]   Corneal aberrations before and after small-incision cataract surgery [J].
Guirao, A ;
Tejedor, J ;
Artal, P .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (12) :4312-4319
[8]  
Holladay JT, 2002, J REFRACT SURG, V18, P683
[9]   CONTRAST SENSITIVITY TESTING - A MORE COMPLETE ASSESSMENT OF VISION [J].
JINDRA, LF ;
ZEMON, V .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (02) :141-148
[10]   Impact of a modified optic design on visual function: Clinical comparative study [J].
Mester, U ;
Dillinger, P ;
Anterist, N .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04) :652-660