Noninvasive, real time laser Doppler flowmetry in perfusion regions and larger vessels

被引:1
|
作者
Elter, P [1 ]
Seiter, E [1 ]
Karch, T [1 ]
Stork, W [1 ]
Müller-Glaser, KD [1 ]
Lutter, N [1 ]
机构
[1] Univ Karlsruhe, Inst Tech Informat Verarbeitung, Karlsruhe, Germany
来源
BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS | 1999年 / 3570卷
关键词
laser; Doppler; flowmetry; real time; autoregressive;
D O I
10.1117/12.336946
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This paper describes an enhanced noninvasive continuous laser Doppler system for real time blood flow measurements in perfusion regions and larger vessels. The system consists of a miniaturized sensor, a fast digital signal processing (DSP) unit and a PC for signal visualization. The sensor comprises an IR laser diode to illuminate tissue through a short optical fiber with a variable spot size of 400 mu m to 1000 mu m and a photodetector which can be positioned 3 mm to 7 mm from the laser spot. The DSP of the system uses a parametric estimation of the laser Doppler power spectrum density based on a first order autoregressive process model BR(1) to calculate the first weighted moment. This algorithm is approx, ten times faster and as accurate as equivalent FFT based algorithms. With a sampling rate of 390 kHz it is possible to calculate and visualize 85 flow values per second. Model measurements prove very high linear correlations (r greater than or equal to 0.99) between calculated first moments and flow velocities in a range from 1 mm/s up to 120 mm/s. Furthermore, in vivo measurements of blood flow both in perfusion regions and larger arteries such as the a. radialis were successfully performed in real time.
引用
收藏
页码:244 / 254
页数:11
相关论文
共 6 条
  • [1] Noninvasive and nonocclusive determination of blood pressure using laser Doppler flowmetry
    Elter, P
    Stork, W
    Müller-Glaser, KD
    Lutter, N
    SPECIALTY FIBER OPTICS FOR MEDICAL APPLICATIONS, PROCEEDINGS OF, 1999, 3596 : 188 - 196
  • [2] Diffusion model for iontophoresis measured by laser-Doppler perfusion flowmetry, applied to normal and preeclamptic pregnancies
    de Mul, Frits F. M.
    Blaauw, Judith
    Smit, Andries J.
    Rakhorst, Gerhard
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (01)
  • [3] Real-time Doppler ultrasound to identify vessels and guide needle placement for gynecologic interstitial brachytherapy
    Sethi, Rajni
    Kuo, Yueh Chun
    Edraki, Babak
    Lerner, Dimitry
    Paik, Daniel
    Bice, William
    BRACHYTHERAPY, 2018, 17 (05) : 742 - 746
  • [4] Relationship between healing time and mean perfusion units of laser Doppler imaging (LDI) in pediatric burns
    Cho, Jin Kyung
    Moon, Duk Ju
    Kim, Seon Gyu
    Lee, Ha Guen
    Chung, Sung Pil
    Yoon, Cheon Jae
    BURNS, 2009, 35 (06) : 818 - 823
  • [5] Real-time estimator of laser Doppler Anemometer signal parameters based on Kalman filtering
    Gaudo, T.
    Rais, B.
    2009 16TH INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING, VOLS 1 AND 2, 2009, : 1103 - +
  • [6] Real-time assessment of renal cortical microvascular perfusion heterogeneities using near-infrared laser speckle imaging
    Bezemer, Rick
    Legrand, Matthieu
    Klijn, Eva
    Heger, Michal
    Post, Ivo C. J. H.
    van Gulik, Thomas M.
    Payen, Didier
    Ince, Can
    OPTICS EXPRESS, 2010, 18 (14): : 15054 - 15061