Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold

被引:87
作者
Kido, Tomoyuki [1 ]
Kido, Teruhito [1 ]
Nakamura, Masashi [2 ]
Watanabe, Kouki [3 ]
Schmidt, Michaela [4 ]
Forman, Christoph [4 ]
Mochizuki, Teruhito [1 ]
机构
[1] Ehime Univ, Dept Radiol, Grad Sch Med, Toon, Ehime 7910295, Japan
[2] Saiseikai Matsuyama Hosp, Dept Radiol, 880-2 Yamanishi, Matsuyama, Ehime 7918026, Japan
[3] Saiseikai Matsuyama Hosp, Dept Cardiol, 880-2 Yamanishi, Matsuyama, Ehime 7918026, Japan
[4] Siemens Healthcare GmbH, Allee Roethelheimpk 2, D-91052 Erlangen, Germany
关键词
Cardiac function; Cardiovascular magnetic resonance; Compressed sensing; Left ventricular ejection fraction; Real-time imaging; EJECTION FRACTION; MYOCARDIAL-INFARCTION; HEART-FAILURE; RADIAL GRAPPA; DYNAMIC MRI; REPRODUCIBILITY; VOLUMES; ECHOCARDIOGRAPHY; RESOLUTION; CMR;
D O I
10.1186/s12968-016-0271-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Backround: Cardiovascular cine magnetic resonance (CMR) accelerated by compressed sensing (CS) is used to assess left ventricular (LV) function. However, it is difficult for prospective CS cine CMR to capture the complete end-diastolic phase, which can lead to underestimation of the end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), compared to retrospective standard cine CMR. This prospective study aimed to evaluate the diagnostic quality and accuracy of single-breath-hold full cardiac cycle CS cine CMR, acquired over two heart beats, to quantify LV volume in comparison to multi-breath-hold standard cine CMR. Methods: Eighty-one participants underwent standard segmented breath-hold cine and CS real-time cine CMR examinations to obtain a stack of eight contiguous short-axis images with same high spatial (1.7 x 1. 7 mm(2)) and temporal resolution (41 ms). Two radiologists independently performed qualitative analysis of image quality (score, 1 [i.e., "nondiagnostic"] to 5 [i.e., "excellent"]) and quantitative analysis of the LV volume measurements. Results: The total examination time was 113 +/- 7 s for standard cine CMR and 24 +/- 4 s for CS cine CMR (p < 0.0001). The CS cine image quality was slightly lower than standard cine (4.8 +/- 0.5 for standard vs. 4.4 +/- 0.5 for CS; p < 0.0001). However, all image quality scores for CS cine were above 4 (i.e., good). No significant differences existed between standard and CS cine MR for all quantitative LV measurements. The mean differences with 95 % confidence interval (CI), based on Bland-Altman analysis, were 1.3 mL (95 % CI, -14.6 - 17.2) for LV end-diastolic volume, 0.2 mL (95 % CI, -9.8 to10.3) for LV end-systolic volume, 1.1 mL (95 % CI,-10.5 to 12.7) for LV stroke volume, 1.0 g (95 % CI, -11.2 to 13.3) for LV mass, and 0.4 % (95 % CI, -4.8 - 5.6) for LV ejection fraction. The interobserver and intraobserver variability for CS cine MR ranged from -4.8 - 1.6 % and from -7.3 - 9.3 %, respectively, with slopes of the regressions ranging 0.88-1.0 and 0.86-1.03, respectively. Conclusions: Single-breath-hold full cardiac cycle CS real-time cine CMR could evaluate LV volume with excellent accuracy. It may replace multi-breath-hold standard cine CMR.
引用
收藏
页数:11
相关论文
共 42 条
[1]   Evaluation of left ventricular ejection fraction using through-time radial GRAPPA [J].
Aandal, Gunhild ;
Nadig, Vidya ;
Yeh, Victoria ;
Rajiah, Prabhakar ;
Jenkins, Trevor ;
Sattar, Abdus ;
Griswold, Mark ;
Gulani, Vikas ;
Gilkeson, Robert C. ;
Seiberlich, Nicole .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
[2]   Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences [J].
Alfakih, K ;
Plein, S ;
Thiele, H ;
Jones, T ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :323-329
[3]   Diabetes Mellitus: Long-term Prognostic Value of Whole-Body MR Imaging for the Occurrence of Cardiac and Cerebrovascular Events [J].
Bamberg, Fabian ;
Parhofer, Klaus G. ;
Lochner, Elena ;
Marcus, Roy P. ;
Theisen, Daniel ;
Findeisen, Hannes M. ;
Hoffmann, Udo ;
Schoenberg, Stefan O. ;
Schlett, Christopher L. ;
Reiser, Maximilian F. ;
Weckbach, Sabine .
RADIOLOGY, 2013, 269 (03) :730-737
[4]   Evaluation of highly accelerated real-time cardiac cine MRI in tachycardia [J].
Bassett, Elwin C. ;
Kholmovski, Eugene G. ;
Wilson, Brent D. ;
DiBella, Edward V. R. ;
Dosdall, Derek J. ;
Ranjan, Ravi ;
McGann, Christopher J. ;
Kim, Daniel .
NMR IN BIOMEDICINE, 2014, 27 (02) :175-182
[5]  
Candès EJ, 2008, IEEE SIGNAL PROC MAG, V25, P21, DOI 10.1109/MSP.2007.914731
[6]   REPRODUCIBILITY OF ANGIOGRAPHIC LEFT VENTRICULAR EJECTION FRACTION IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
COHN, PF ;
LEVINE, JA ;
BERGERON, GA ;
GORLIN, R .
AMERICAN HEART JOURNAL, 1974, 88 (06) :713-720
[7]   The association of left ventricular ejection fraction, mortality, and cause of death in stable outpatients with heart failure [J].
Curtis, JP ;
Sokol, SI ;
Wang, YF ;
Rathore, SS ;
Ko, DT ;
Jadbabaie, F ;
Portnay, EL ;
Marshalko, SJ ;
Radford, MJ ;
Krumholz, HM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (04) :736-742
[8]   Operator induced variability in cardiovascular MR: left ventricular measurements and their reproducibility [J].
Danilouchkine, MG ;
Westenberg, JJM ;
de Roos, A ;
Reiber, JHC ;
Lelieveldt, BPF .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (02) :447-457
[9]   Performance of 3-Dimensional Echocardiography in Measuring Left Ventricular Volumes and Ejection Fraction [J].
Dorosz, Jennifer L. ;
Lezotte, Dennis C. ;
Weitzenkamp, David A. ;
Allen, Larry A. ;
Salcedo, Ernesto E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (20) :1799-1808
[10]   Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique (TPAT) and 4D guide-point modelling analysis of left ventricular function [J].
Eberle, Holger C. ;
Nassenstein, Kai ;
Jensen, Christoph J. ;
Schlosser, Thomas ;
Sabin, Georg V. ;
Naber, Christoph K. ;
Bruder, Oliver .
EUROPEAN RADIOLOGY, 2010, 20 (01) :73-80