Image Quality Assessment of Digital Image Capturing Devices for Melanoma Detection

被引:9
作者
Dugonik, Bogdan [1 ]
Dugonik, Aleksandra [2 ]
Marovt, Maruska [2 ]
Golob, Marjan [1 ]
机构
[1] Univ Maribor, Fac Elect Engn & Comp Sci, Maribor 2000, Slovenia
[2] Univ Med Ctr Maribor, Dept Dermatol, Maribor 2000, Slovenia
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 08期
关键词
dermoscopy; melanoma detection; mole screening; image quality; colour response; spatial frequency response; image resolution; image sharpness; TECHNIQUE STANDARDS; NAKED EYE; FOLLOW-UP; HIGH-RISK; DERMOSCOPY; DIAGNOSIS; DERMATOSCOPY; METAANALYSIS; ACQUISITION; GUIDELINES;
D O I
10.3390/app10082876
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The fast-growing incidence of skin cancer, especially melanoma, is the guiding principle for intense development of various digital image-capturing devices providing easier recognition of melanoma by dermatologists. Handheld and digital dermoscopy, following of mole changes with smartphones and digital analysing of mole images, is based on evaluation of the colours, shape and deep structures in the skin moles. Incorrect colour information of an image, under- or overexposed images, lack of sharpness and low resolution of the images, can lead to melanoma misdiagnosis. The purpose of our study was to determine the colour error in the image according to the given lighting conditions and different camera settings. We focused on measuring the image quality parameters of smartphones and high-resolution cameras to compare them with the results of state-of-the-art dermoscopy device systems. We applied standardised measuring methods. The spatial frequency response method was applied for measuring the sharpness and resolution of the tested camera systems. Colour images with known reference values were captured from the test target, to evaluate colour error as a CIELAB (Commission Internationale de l'Eclairage) Delta E*(ab) colour difference as seen by a human observer. The results of our measurements yielded two significant findings. First, all tested cameras produced inaccurate colours when operating in automatic mode, and second, the amount of sharpening was too intensive. These deficiencies can be eliminated through adjusting the camera parameters manually or by image post-production. The presented two-step camera calibration procedure improves the colour accuracy of captured clinical and dermoscopy images significantly.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Perceptual image quality in digital dermoscopy
    Avanaki, A.
    Espig, K.
    Xthona, A.
    Brooks, D.
    Young, J.
    Kimpe, T.
    MEDICAL IMAGING 2020: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2020, 11316
  • [2] Skin lesion image segmentation using Delaunay Triangulation for melanoma detection
    Pennisi, Andrea
    Bloisi, Domenico D.
    Nardi, Daniele
    Giampetruzzi, Anna Rita
    Mondino, Chiara
    Facchiano, Antonio
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2016, 52 : 89 - 103
  • [3] Image quality assessment based on noise detection
    Joshi, Piyush
    Prakash, Surya
    2014 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2014, : 755 - 759
  • [4] Digital breast tomosynthesis: Dose and image quality assessment
    Maldera, A.
    De Marco, P.
    Colombo, P. E.
    Origgi, D.
    Torresin, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 56 - 67
  • [5] Melanoma diagnosed on digital dermoscopy monitoring: A side-by-side image comparison is needed to improve early detection
    Babino, Graziella
    Lallas, Aimilios
    Agozzino, Marina
    Alfano, Roberto
    Apalla, Zoe
    Brancaccio, Gabriella
    Giorgio, Caterina M.
    Fulgione, Elisabetta
    Kittler, Harald
    Kyrgidis, Athanassios
    Papageorgiou, Chryssuola
    Argenziano, Giuseppe
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2021, 85 (03) : 619 - 625
  • [6] Image quality assessment for teledermatology: from consumer devices to a dedicated medical device
    Amouroux, Marine
    Le Cunff, Sebastien
    Haudrechy, Alexandre
    Blondel, Walter
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES X, 2017, 10056
  • [7] Image Processing and SVM Classification for Melanoma Detection
    Mustafa, Suleiman
    Dauda, Ali Baba
    Dauda, Mohammed
    PROCEEDINGS OF THE IEEE INTERNATIONAL CONFERENCE ON COMPUTING NETWORKING AND INFORMATICS (ICCNI 2017), 2017,
  • [8] Incorporating detection tasks into the assessment of CT image quality
    Scalzetti, E. M.
    Huda, W.
    Ogden, K. M.
    Khan, M.
    Roskopf, M. L.
    Ogden, D.
    MEDICAL IMAGING 2006: IMAGE PERCEPTION, OBSERVER PERFORMANCE AND TECHNOLOGY ASSESSMENT, 2006, 6146
  • [9] Digital chest radiography image quality assessment with dose reduction
    R. K. Grewal
    N. Young
    L. Collins
    N. Karunaratne
    R. Sabharwal
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 71 - 80
  • [10] The missing link in image quality assessment in digital dental radiography
    Okamura, Kazutoshi
    Yoshiura, Kazunori
    ORAL RADIOLOGY, 2020, 36 (04) : 313 - 319