Evaluation of ionic air purifiers for reducing aerosol exposure in confined indoor spaces

被引:110
作者
Grinshpun, SA [1 ]
Mainelis, G [1 ]
Trunov, M [1 ]
Adhikari, A [1 ]
Reponen, T [1 ]
Willeke, K [1 ]
机构
[1] Univ Cincinnati, Dept Environm Hlth, Ctr Hlth Related Aerosol Studies, Cincinnati, OH 45267 USA
关键词
indoor air purification; aerosol concentration; particle size; ionization; electric charge;
D O I
10.1111/j.1600-0668.2005.00364.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Numerous techniques have been developed over the years for reducing aerosol exposure in indoor air environments. Among indoor air purifiers of different types, ionic emitters have gained increasing attention and are presently used for removing dust particles, aeroallergens and airborne microorganisms from indoor air. In this study, five ionic air purifiers (two wearable and three stationary) that produce unipolar air ions were evaluated with respect to their ability to reduce aerosol exposure in confined indoor spaces. The concentration decay of respirable particles of different properties was monitored in real time inside the breathing zone of a human manikin, which was placed in a relatively small (2.6 m(3)) walk-in chamber during the operation of an ionic air purifier in calm air and under mixing air condition. The particle removal efficiency as a function of particle size was determined using the data collected with a size-selective optical particle counter. The removal efficiency of the more powerful of the two wearable ionic purifiers reached about 50% after 15 min and almost 100% after 1.5 h of continuous operation in the chamber under calm air conditions. In the absence of external ventilation, air mixing, especially vigorous one (900 CFM), enhanced the air cleaning effect. Similar results were obtained when the manikin was placed inside a partial enclosure that simulated an aircraft seating configuration. All three stationary ionic air purifiers tested in this study were found capable of reducing the aerosol concentration in a confined indoor space. The most powerful stationary unit demonstrated an extremely high particle removal efficiency that increased sharply to almost 90% within 5-6 min, reaching about 100% within 10-12 min for all particle sizes (0.3-3 mu m) tested in the chamber. For the units of the same emission rate, the data suggest that the ion polarity per se (negative vs. positive) does not affect the performance but the ion emission rate does. The effects of particle size (within the tested range) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria) as well as the effects of the manikin's body temperature and its breathing on the ionic purifier performance were either small or insignificant. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when used inside confined spaces with a relatively high surface-to-volume ratio.
引用
收藏
页码:235 / 245
页数:11
相关论文
共 45 条
[1]   Characterization of indoor particle sources: A study conducted in the metropolitan Boston area [J].
Abt, E ;
Suh, HH ;
Allen, G ;
Koutrakis, P .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (01) :35-44
[2]  
*AM LUNG ASS, 1997, RES AIR CLEAN DEV TY
[3]  
[Anonymous], 1991, INDOOR AIR POLLUTION
[4]   ON THE EFFECT OF A NEGATIVE ION-GENERATOR AND A MIXING FAN ON THE PLATE-OUT OF RADON DECAY PRODUCTS IN A RADON BOX [J].
BIGU, J .
HEALTH PHYSICS, 1983, 44 (03) :259-266
[5]  
Bohgard M., 1998, J AEROSOL SCI, V29, pS1313
[7]   TRIAL OF A NEGATIVE-ION GENERATOR DEVICE IN REMEDIATING PROBLEMS RELATED TO INDOOR AIR-QUALITY [J].
DANIELL, W ;
CAMP, J ;
HORSTMAN, S .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1991, 33 (06) :681-687
[8]  
Gammage R.B., 1996, Indoor Air and Human Health, V2nd ed.
[10]   Effectiveness of indoor air cleaning with corona ionizers [J].
Grabarczyk, Z .