Low-dose versus high-dose heparin locks for hemodialysis catheters: a systematic review and meta-analysis

被引:20
作者
Han, Xin [1 ]
Yang, Xiaoli [1 ]
Huang, Bihong [2 ]
Yuan, Li [2 ]
Cao, Yanpei [1 ]
机构
[1] Fudan Univ, Huashan Hosp, Dept Nursing, 12 Urumqi Middle Rd, Shanghai 200040, Peoples R China
[2] Fudan Univ, Huashan Hosp, Dept Nephrol, Shanghai, Peoples R China
关键词
heparin locks; hemodialysis; central venous catheter; meta-analysis; systematic review; VENOUS CATHETER; CITRATE; RISK;
D O I
10.5414/CN108701
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Low-dose heparin lock has been suggested as an effective and safe catheter lock in hemodialysis. However, whether a low-dose lock is superior to a high-dose heparin lock in preventing catheter-related infections and maintaining catheter patency is inconclusive. Study design: A systematic review and meta-analysis was performed by searching in NGC (National Guideline Clearinghouse), Cochrane Library, Joanna Briggs Institute Library, MEDLINE, EMbase, RNAO (Registered Nurses' Association of Ontario), Nursing Consult, PubMed, OVID, China Biology Medicine disc (CBMdisc), China National Knowledge Infrastructure (CNKI), Chongqing VIP (CQVIP), Wanfang Data Knowledge Service Platform, and major nephrology journals. Setting and population: Patients receiving hemodialysis with central venous catheters. Selection criteria for studies: Randomized controlled trials (RCT), controlled clinical trials (CCT), and cohort studies comparing low-dose heparin lock with high-dose heparin lock in hemodialysis patients with central venous catheters. Intervention (exposure): Locking central venous catheters with low-dose heparin lock. Outcomes: Primary outcomes include bleeding-related complications and catheter-related infections. Secondary outcomes include catheter retention time, catheter thrombosis/occlusion incidence, and catheter dysfunction. Results: Five RCTs and three CCTs were eventually identified for the meta-analysis, with 916 patients in total. Meta-analysis showed that, compared with the high-dose heparin group (>= 5,000 U/mL), the low-dose (< 5,000 U/mL) heparin lock could significantly reduce the incidences of bleeding-related complications RR = 3.29, 95% CI (2.19, 4.94), p < 0.00001) and catheterrelated infections (RR = 1.66, 95% CI (1.01, 2.73), p = 0.04). However, no significant differences were observed in the catheter retention time MD = 9.32, 95% CI (-6.70, 25.35), p = 0.25), catheter thrombosis/occlusion incidence (RR = 0.68, 95% CI (0.28, 1.65), p = 0.39), or catheter dysfunction (RR = 1.07, 95% CI (0.75, 1.53), p = 0.71) between the high-and low-dose heparin groups. Conclusion: Low-dose heparin lock could decrease the incidences of catheter-related infections and bleeding-related complications without influencing the catheter retention time or the incidence of catheter thrombosis/occlusion or catheter dysfunction. Low-dose heparin lock solution should be recommended for the hemodialysis patients using central venous catheter in clinic.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 22 条
[1]   Estimation of heparin leak into the systemic circulation after central venous catheter heparin lock [J].
Agharazii, M ;
Plamondon, I ;
Lebel, M ;
Douville, P ;
Desmeules, S .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 (06) :1238-1240
[2]   Renal Association Clinical Practice Guideline on Vascular Access for Haemodialysis [J].
Fluck, Richard ;
Kumwenda, Mick .
NEPHRON CLINICAL PRACTICE, 2011, 118 :C225-C240
[3]   Sodium citrate 4% locking solution for central venous dialysis catheters - an effective, more cost-efficient alternative to heparin [J].
Grudzinski, Linda ;
Quinan, Patricia ;
Kwok, Sophie ;
Pierratos, Andreas .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (02) :471-476
[4]   Low-Dose Heparin Retention in Temporary Hemodialysis Double-Lumen Catheter Does Not Increase Catheter Occlusion and Might Reduce Risk of Bleeding [J].
Hu, Hao-Huan ;
Hsu, Chih-Yang ;
Fang, Hua-Chang ;
Lee, Po-Tsang ;
Chen, Chien-Liang ;
Chang, Tsu-Yuan ;
Huang, Wei-Chieh ;
Chung, Hsiao-Min ;
Chou, Kang-Ju .
BLOOD PURIFICATION, 2011, 32 (03) :232-237
[5]   Risk of heparin lock-related bleeding when using indwelling venous catheter in haemodialysis [J].
Karaaslan, H ;
Peyronnet, P ;
Benevent, D ;
Lagarde, C ;
Rince, M ;
Leroux-Robert, C .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (10) :2072-2074
[6]  
Li L, 2011, CHINESE J MISDIAGNOS, V11, P7389
[7]  
Li X, 2007, THEORY AND PRACTICE
[8]  
Lu J, 2012, CHINESE MED GUIDES, V9, P66
[9]   Does the Heparin Lock Concentration Affect Hemodialysis Catheter Patency? [J].
Maya, Ivan D. ;
Smith, Tamorie ;
Allon, Michael .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2010, 5 (08) :1458-1462
[10]   Heparin stimulates Staphylococcus aureus biofilm formation [J].
Shanks, RMQ ;
Donegan, NP ;
Graber, ML ;
Buckingham, SE ;
Zegans, ME ;
Cheung, AL ;
O'Toole, GA .
INFECTION AND IMMUNITY, 2005, 73 (08) :4596-4606