A novel electrochemical sensor for determination of hydroquinone in water using FeWO4/SnO2 nanocomposite immobilized modified glassy carbon electrode

被引:44
作者
Karthika, A. [1 ]
Raja, V. Ramasamy [2 ]
Karuppasamy, P. [5 ]
Suganthi, A. [1 ,3 ]
Rajarajan, M. [4 ]
机构
[1] Thiagarajar Coll, PG & Res Dept Chem, Madurai 625009, Tamil Nadu, India
[2] KP Natl Coll Arts & Sci, Dept Chem, Batlagundu 624202, Tamil Nadu, India
[3] Mother Teresa Womens Univ, Kodaikanal 624102, Tamil Nadu, India
[4] Madurai Kamaraj Univ, Madurai 62502, Tamil Nadu, India
[5] Anna Univ, Tirunelveli 627006, Tamil Nadu, India
关键词
Electrochemical methods; Anti-interference; Amperometric method; HQ sensor; REDUCED GRAPHENE OXIDE; DIHYDROXYBENZENE ISOMERS; CHEMICAL SENSOR; ELECTROCATALYTIC OXIDATION; PHOTOCATALYTIC ACTIVITY; HYDROTHERMAL SYNTHESIS; HYDROGEN-PEROXIDE; MESOPOROUS CARBON; HOLLOW-SPHERES; URIC-ACID;
D O I
10.1016/j.arabjc.2019.06.008
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel electrochemical sensor based on iron tungstate doped tin oxide nanocomposite Nafion (FeWO4/SnO2/Nf) immobilized modified glassy carbon electrode (GCE) is fabricated to determine hydroquinone (HQ) in this present study. The structural morphology and phase of FeWO4/SnO2 nanocomposite are characterized by X-ray powder diffraction (XRD), energy dispersive X-ray analysis (EDX), Fourier transform infrared spectroscopy (FT-IR), high transmission electron microscopy (HR-TEM) and Field emission scanning electron microscopy (FE-SEM), Brunauer-Emmett-Teller (BET) and X-ray photoelectron spectroscopy (XPS) respectively. Electrochemical methods such as cyclic voltammetry (CV), difference pulse voltammetry (DPV) and amperometric (i-t curve) are used to describe the electrochemical performance of the surface modified electrode for HQ sensing studies. The FeWO4/SnO2/Nf immobilized GCE is exhibited excellent catalytic activity with the increasing current signal during HQ sensing. The linear range of response is obtained between 0.01 mu M and 50 mu M for HQ detection under optimized conditions and the low detection limit (LOD) is found to be 0.0013 mu M. Moreover, the present modified electrode shows good reproducibility and excellent anti-interference behavior. In addition, the present electrochemical sensor is applied to the real samples of collected waters from various sources and the obtained experimental results are quite satisfactory. (C) 2019 Production and hosting by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:4065 / 4081
页数:17
相关论文
共 50 条
  • [31] A novel amperometric sensor based on intercalated montmorillonite modified carbon paste electrode for hydroquinone determination
    Kong, Yong
    Ma, Mengjie
    Mao, Huihui
    Ma, Jiangquan
    Yao, Chao
    ANALYTICAL METHODS, 2012, 4 (03) : 748 - 752
  • [32] Electrochemical sensor using glassy carbon electrode modified with acylpyrazolone-multiwalled carbon nanotube composite film for determination of xanthine
    Song, Yun
    Li, Jinzhou
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (02) : 689 - 695
  • [33] Electrochemical sensor using glassy carbon electrode modified with acylpyrazolone-multiwalled carbon nanotube composite film for determination of xanthine
    Yun Song
    Jinzhou Li
    Journal of Solid State Electrochemistry, 2012, 16 : 689 - 695
  • [34] Glassy Carbon Electrode Modified with C/Au Nanostructured Materials for Simultaneous Determination of Hydroquinone and Catechol in Water Matrices
    Pina, Samuel
    Candia-Onfray, Christian
    Hassan, Natalia
    Jara-Ulloa, Paola
    Contreras, David
    Salazar, Ricardo
    CHEMOSENSORS, 2021, 9 (05)
  • [35] An electrochemical sensor for the simultaneous determination of rifampicin and isoniazid using a C-dots@CuFe2O4 nanocomposite modified carbon paste electrode
    Shiri, Sajad
    Pajouheshpoor, Niyoosha
    Khoshsafar, Hosein
    Amidi, Salimeh
    Bagheri, Hasan
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (24) : 15564 - 15573
  • [36] Electrochemical sensor for simultaneous determination of ascorbic acid, uric acid and folic acid based on Mn-SnO2 nanoparticles modified glassy carbon electrode
    Lavanya, N.
    Fazio, E.
    Neri, F.
    Bonavita, A.
    Leonardi, S. G.
    Neri, G.
    Sekar, C.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 770 : 23 - 32
  • [37] Sensitive and selective electrochemical sensor using silver nanoparticles modified glassy carbon electrode for determination of cholesterol in bovine serum
    Nantaphol, Siriwan
    Chailapakul, Orawon
    Siangproh, Weena
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 193 - 198
  • [38] Eco-friendly synthesized silver-magnetic nanocomposite supported on nanocellulose modified glassy carbon electrode as an electrochemical sensor for simultaneous determination of dopamine and acetaminophen
    Alhamzani, Abdulrahman G.
    Mahdy, Al-Hassan S.
    Abou-Krisha, Mortaga M.
    Yousef, Tarek A.
    Abd-Elsabour, M.
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 364
  • [39] Cost-Effective Electrochemical Sensor Based on Carbon Nanotube Modified-Pencil Electrode for the Simultaneous Determination of Hydroquinone and Catechol
    Ahammad, A. J. Saleh
    Akter, Tania
    Al Mamun, Abdullah
    Islam, Tamanna
    Hasan, Md. Mahedi
    Mamun, M. A.
    Faraezi, S.
    Monira, F. Z.
    Saha, Joyanta K.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (09) : B390 - B397
  • [40] Simultaneous determination of catechol and hydroquinone using a Pt/ZrO2-RGO/GCE composite modified glassy carbon electrode
    Vilian, A. T. Ezhil
    Chen, Shen-Ming
    Huang, Lin-Hsiang
    Ali, M. Ajmal
    Al-Hemaid, Fahad M. A.
    ELECTROCHIMICA ACTA, 2014, 125 : 503 - 509