A novel electrochemical sensor for determination of hydroquinone in water using FeWO4/SnO2 nanocomposite immobilized modified glassy carbon electrode

被引:44
作者
Karthika, A. [1 ]
Raja, V. Ramasamy [2 ]
Karuppasamy, P. [5 ]
Suganthi, A. [1 ,3 ]
Rajarajan, M. [4 ]
机构
[1] Thiagarajar Coll, PG & Res Dept Chem, Madurai 625009, Tamil Nadu, India
[2] KP Natl Coll Arts & Sci, Dept Chem, Batlagundu 624202, Tamil Nadu, India
[3] Mother Teresa Womens Univ, Kodaikanal 624102, Tamil Nadu, India
[4] Madurai Kamaraj Univ, Madurai 62502, Tamil Nadu, India
[5] Anna Univ, Tirunelveli 627006, Tamil Nadu, India
关键词
Electrochemical methods; Anti-interference; Amperometric method; HQ sensor; REDUCED GRAPHENE OXIDE; DIHYDROXYBENZENE ISOMERS; CHEMICAL SENSOR; ELECTROCATALYTIC OXIDATION; PHOTOCATALYTIC ACTIVITY; HYDROTHERMAL SYNTHESIS; HYDROGEN-PEROXIDE; MESOPOROUS CARBON; HOLLOW-SPHERES; URIC-ACID;
D O I
10.1016/j.arabjc.2019.06.008
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel electrochemical sensor based on iron tungstate doped tin oxide nanocomposite Nafion (FeWO4/SnO2/Nf) immobilized modified glassy carbon electrode (GCE) is fabricated to determine hydroquinone (HQ) in this present study. The structural morphology and phase of FeWO4/SnO2 nanocomposite are characterized by X-ray powder diffraction (XRD), energy dispersive X-ray analysis (EDX), Fourier transform infrared spectroscopy (FT-IR), high transmission electron microscopy (HR-TEM) and Field emission scanning electron microscopy (FE-SEM), Brunauer-Emmett-Teller (BET) and X-ray photoelectron spectroscopy (XPS) respectively. Electrochemical methods such as cyclic voltammetry (CV), difference pulse voltammetry (DPV) and amperometric (i-t curve) are used to describe the electrochemical performance of the surface modified electrode for HQ sensing studies. The FeWO4/SnO2/Nf immobilized GCE is exhibited excellent catalytic activity with the increasing current signal during HQ sensing. The linear range of response is obtained between 0.01 mu M and 50 mu M for HQ detection under optimized conditions and the low detection limit (LOD) is found to be 0.0013 mu M. Moreover, the present modified electrode shows good reproducibility and excellent anti-interference behavior. In addition, the present electrochemical sensor is applied to the real samples of collected waters from various sources and the obtained experimental results are quite satisfactory. (C) 2019 Production and hosting by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:4065 / 4081
页数:17
相关论文
共 50 条
  • [21] A voltammetric sensor based on eosin Y film modified glassy carbon electrode for simultaneous determination of hydroquinone and catechol
    He, Jiahong
    Qiu, Ri
    Li, Wenpo
    Xing, Shaohua
    Song, Zhongrong
    Li, Qiang
    Zhang, Shengtao
    ANALYTICAL METHODS, 2014, 6 (16) : 6494 - 6503
  • [22] Voltammetric Determination of Dopamine Using Glassy Carbon Electrode Modified with ZnO/Al2O3 Nanocomposite
    Ganjali, Mohammad Reza
    Beitollahi, Hadi
    Zaimbashi, Reza
    Tajik, Somayeh
    Rezapour, Morteza
    Larijani, Bagher
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (03): : 2519 - 2529
  • [23] A sensitive electrochemical sensor for the determination of carvedilol based on a modified glassy carbon electrode with ordered mesoporous carbon
    Rofouei, Mohammad Kazem
    Khoshsafar, Hamid
    Kalbasi, Roozbeh Javad
    Bagheri, Hasan
    RSC ADVANCES, 2016, 6 (16): : 13160 - 13167
  • [24] Electrochemical Derivatization of Acetaminophen for Indirect Determination of Eflornithine Using β-CD Modified Glassy Carbon Electrode
    Barnaji, Bahareh Feyzi
    Salehzadeh, Hamid
    Darbasizadeh, Behzad
    Dinarvand, Rassoul
    Salimi, Abdollah
    Mohammadi, Ali
    ELECTROANALYSIS, 2019, 31 (09) : 1719 - 1727
  • [25] Electrochemical detection of bisphenol a on a MWCNTs/CuFe2O4 nanocomposite modified glassy carbon electrode
    Baghayeri, Mehdi
    Amiri, Amirhassan
    Fayazi, Maryam
    Nodehi, Marzieh
    Esmaeelnia, Ali
    MATERIALS CHEMISTRY AND PHYSICS, 2021, 261
  • [26] Simultaneous Electrochemical Determination of Serotonin, Melatonin and Tryptophan using A Glassy Carbon Electrode Modified with CuNi-CeO2-rGO Nanocomposite
    Nikpanje, Elham
    Bahmaei, Manochehr
    Sharif, Amirabdolah Mehrdad
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (05): : 470 - 485
  • [27] A novel nitrite sensor based on graphene/polypyrrole/chitosan nanocomposite modified glassy carbon electrode
    Ye, Daixin
    Luo, Liqiang
    Ding, Yaping
    Chen, Qiang
    Liu, Xiao
    ANALYST, 2011, 136 (21) : 4563 - 4569
  • [28] An electrochemical nanocomposite modified carbon paste electrode as a sensor for simultaneous determination of hydrazine and phenol in water and wastewater samples
    Karimi-Maleh, Hassan
    Moazampour, Mahbobeh
    Ensafi, Ali A.
    Mallakpour, Shadpour
    Hatami, Mehdi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2014, 21 (09) : 5879 - 5888
  • [29] NOVEL HYDROGEN PEROXIDE SENSOR USING A MULTIWALLED CARBON NANOTUBE-COBALAMIN NANOCOMPOSITE GLASSY CARBON ELECTRODE
    Liu, Suqin
    Dai, Gaopeng
    Luo, Tianxiong
    Wang, Jingwen
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2015, 43 (06) : 649 - 660
  • [30] Electrocatalytic oxidation and simultaneous determination of catechol and hydroquinone at a novel carbon nano-fragment modified glassy carbon electrode
    Zhang, Chuyi
    Zeng, Lixuan
    Zhu, Xiaohua
    Yu, Chumei
    Zuo, Xiaoxi
    Xiao, Xin
    Nan, Junmin
    ANALYTICAL METHODS, 2013, 5 (09) : 2203 - 2208