Probabilistic approach to confidence intervals of linear calibration

被引:25
作者
Hayashi, Y
Matsuda, R
Poe, RB
机构
[1] National Institute of Health Sciences, Setagaya, Tokyo 158
关键词
confidence intervals; calibration; probability theory; statistics; Kalman filter;
D O I
10.1039/an9962100591
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is demonstrated that the statistical reliability of experimentally determined confidence intervals in some linear calibration problems in instrumental analyses can greatly be enhanced if the standard deviation (s, sigma(M)) of measurements, which is a theoretical prediction of the instrumental response error, is incorporated into the usual statistical equation instead of the residual of least-squares fitting, The reliability of the calibration depends on not only the fluctuation of calibration lines due to the response error, sigma(M), but also the error of parametrization associated with the a priori response error prediction, i.e., the variance of the response st Var(sigma(M)). The error prediction requires the Fourier transform of an instrumental baseline, signal shape and others (e.g., sample injection error). The variability in the confidence interval from five calibration standards is as small in the probabilistic approach as that for 50 standards in the statistical method, Liquid chromatography and capillary electrophoresis are taken as examples.
引用
收藏
页码:591 / 599
页数:9
相关论文
共 56 条
[1]   REVIEW AND TUTORIAL DISCUSSION OF NOISE AND SIGNAL-TO-NOISE RATIOS IN ANALYTICAL SPECTROMETRY .1. FUNDAMENTAL PRINCIPLES OF SIGNAL-TO-NOISE RATIOS [J].
ALKEMADE, CTJ ;
SNELLEMAN, W ;
BOUTILIER, GD ;
POLLARD, BD ;
WINEFORDNER, JD ;
CHESTER, TL ;
OMENETTO, N .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1978, 33 (08) :383-399
[2]   A REVIEW AND TUTORIAL DISCUSSION OF NOISE AND SIGNAL-TO-NOISE RATIOS IN ANALYTICAL SPECTROMETRY .3. MULTIPLICATIVE NOISES [J].
ALKEMADE, CTJ ;
SNELLEMAN, W ;
BOUTILIER, GD ;
WINEFORDNER, JD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1980, 35 (05) :261-270
[3]   STUDY OF PRECISION IN MODERN LIQUID CHROMATOGRAPHY USING A DEDICATED COMPUTER [J].
BARTH, H ;
DALLMEIE.E ;
COURTOIS, G ;
KELLER, HE ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1973, 83 (AUG29) :289-311
[4]   DETECTION LIMITS AND SPECTRAL INTERFERENCES IN ATOMIC-EMISSION SPECTROMETRY [J].
BOUMANS, PWJM .
ANALYTICAL CHEMISTRY, 1994, 66 (08) :A459-A467
[5]   REVIEW AND TUTORIAL DISCUSSION OF NOISE AND SIGNAL-TO-NOISE RATIOS IN ANALYTICAL SPECTROMETRY .2. FUNDAMENTAL PRINCIPLES OF SIGNAL-TO-NOISE RATIOS [J].
BOUTILIER, GD ;
POLLARD, BD ;
WINEFORDNER, JD ;
CHESTER, TL ;
OMENETTO, N .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1978, 33 (08) :401-416
[6]   DEVELOPMENT AND APPLICATION OF A CALIBRATION REGRESSION ROUTINE IN CONJUNCTION WITH LINEAR AND NONLINEAR CHROMATOGRAPHIC DETECTOR RESPONSES [J].
BURROWS, JL ;
WATSON, KV .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (04) :523-531
[7]   BIAS CORRECTING CONFIDENCE-INTERVALS FOR A NEARLY COMMON PROPERTY [J].
CLINE, DBH ;
SPIEGELMAN, CH .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1991, 11 (02) :131-136
[8]  
CURRIE LA, 1985, ACS SYM SER, V284, P49
[9]   PROBLEMS OF CALIBRATION IN TRACE, INSITU-MICRO AND SURFACE-ANALYSIS [J].
DANZER, K .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (07) :794-801
[10]  
DRAPER NR, 1981, APPLIED REGRESSION A