An Assessment of the Performance of the PLUS plus Tool in Supporting the Evaluation of Water Framework Directive Compliance in Scottish Standing Waters

被引:3
作者
Donnelly, David [1 ]
Helliwell, Rachel C. [1 ]
May, Linda [2 ]
McCreadie, Brian [3 ]
机构
[1] James Hutton Inst, Aberdeen AB15 8QH, Scotland
[2] UK Ctr Ecol & Hydrol, Bush Estate, Penicuik EH26 0QB, Midlothian, Scotland
[3] SEPA, Inverdee House,Baxter St, Aberdeen AB11 9QA, Scotland
关键词
total phosphorus; lakes; reservoirs; PROCESS-BASED MODEL; LONG-TERM; AGRICULTURAL CATCHMENTS; SEASONAL HYPOXIA; PHOSPHORUS; LAKE; MANAGEMENT; NITROGEN; EXPORT; LAND;
D O I
10.3390/ijerph17020391
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Phosphorus is one of the main causes of waterbodies in Scotland being at less than good ecological status (GES) in terms of the water framework directive (WFD). In Scotland, there are more than 8000 standing waters, defined as lakes and reservoirs that have a surface area of more than 1 hectare. Only about 330 of these are monitored routinely to assess compliance with the WFD. The export coefficient tool PLUS+ (phosphorus land use and slope) has been developed to estimate total phosphorus (TP) concentrations in the unmonitored sites; modelled values are then compared to WFD target concentrations for high, good, moderate, poor, and bad status to assess compliance. These type-specific or site-specific targets are set by the regulatory authority and form part of a suite of physical, chemical, and ecological targets that are used to assess GES, all of which must be met. During development, the PLUS+ tool was applied to 323 monitored catchments and 7471 unmonitored catchments. The efficacy of the tool was assessed against TP concentrations observed in 2014 and found to perform well in the rural catchments. 51% of standing waters had the same modelled and observed WFD class (i.e., High, Good, Moderate, Poor, Bad), and a further 40% of standing waters had a modelled WFD class that was within one class of observed water quality. The tool performed less well in catchments with larger inputs of TP from urban sources (e.g., sewage). The greatest deviations between measured and modelled classes were explained by the shortage of information on wastewater treatment works, fish farms, migratory birds, levels of uncertainty in TP measurements, and the amount of in-lake re-cycling of P. The limitations of the tool are assessed using data from six well documented case study sites and recommendations for improving the model performance are proposed.
引用
收藏
页数:24
相关论文
共 52 条
[1]  
Allen R.G., 1998, Paper No. 56
[2]  
[Anonymous], 2000, OFF J EUR COMMUNITIE, V12, P2000
[3]  
Anthony S., 2008, WT0750CSF ADAS UK LT, P59
[4]  
Artz R., 2018, Peatland Restoration - a Comparative Analysis of the Costs and Merits of Different Restoration Methods
[5]  
Artz R.R.E., 2014, 562 SCOTT NAT HER IN
[6]  
Boorman D.B., 1995, 126 I HYDR, P146
[7]  
Brooker N., 1995, DEV GIS BASED TOOL C
[8]  
Carvalho L., 2002, PHYS CHEM CONDITIONS
[9]   Appraisal of phosphorus and sediment transfer in three pilot areas identified for the catchment sensitive farming initiative in England: application of the prototype PSYCHIC model [J].
Collins, A. L. ;
Stromqvist, J. ;
Davison, P. S. ;
Lord, E. I. .
SOIL USE AND MANAGEMENT, 2007, 23 :117-132
[10]   Development of a Chemical Source Apportionment Decision Support Framework for Catchment Management [J].
Comber, Sean D. W. ;
Smith, Russell ;
Daldorph, Peter ;
Gardner, Michael J. ;
Constantino, Carlos ;
Ellor, Brian .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (17) :9824-9832