Sensitive quantification of iodide by ion-exchange chromatography with electrochemical detection at a modified platinum electrode

被引:24
作者
Cataldi, TRI [1 ]
Rubino, A [1 ]
Ciriello, R [1 ]
机构
[1] Univ Basilicata, Dipartimento Chim, I-85100 Potenza, Italy
关键词
iodine; ion chromatography; electrochemical detection; modified electrode; wastewater; seawater;
D O I
10.1007/s00216-005-3187-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and very sensitive method for the accurate determination of free iodide in real samples is described. The method is based on anion-exchange chromatographic separation coupled with amperometric detection at a modified platinum electrode under constant applied potential (+0.85 V vs. Ag AgCl). An experimental setup with an in-line and very effective method of electrode modification is proposed using an amperometric thin-layer cross-flow detector and a. owing solution 300 mg/ L of iodide; the working electrode is polarised to the limiting current for oxidation of iodide to iodine in acidic solutions with the consequent formation of an iodine-based film. The results indicated that the modified electrode exhibits high analytical response for iodide electrooxidation with good stability and long-life. The signal intensity of daily experimental sessions (8 h), during which standards and real samples were repeatedly injected, exhibits a moderate lowering (i.e. < 6%). Using a mixture of 25 mM HNO3 and 50 mM NaNO3 as an eluent phase in ion-exchange chromatography, the detection limit of iodide was estimated to be 0.5 mu g/L (S/N= 3) with an injection volume of 50 mu L. This method was applied successfully to quantify the iodide content of milk samples and in wastewaters as well as trace amounts in common vegetables and solutions containing high chloride levels.
引用
收藏
页码:134 / 141
页数:8
相关论文
共 46 条
[1]   Laser-activated voltammetry.: Mechanism of aqueous iodide oxidation at platinum electrodes:: Theory and experiment [J].
Akkermans, RP ;
Qiu, FL ;
Roberts, SL ;
Suárez, MF ;
Compton, RG .
JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (39) :8319-8327
[2]   Ion chromatographic determination of iodide in urine and serum using a tubular ion-selective electrode based on a homogeneous crystalline membrane [J].
Almeida, AA ;
Jun, X ;
Lima, JLFC .
MIKROCHIMICA ACTA, 1997, 127 (1-2) :55-60
[3]  
ANDREWS GR, 1984, J SOC DAIRY TECHNOL, V37, P92, DOI 10.1111/j.1471-0307.1984.tb00498.x
[4]  
[Anonymous], 122 DION CORP
[5]  
[Anonymous], 1976, ELECTROCHEMICAL STRI
[6]   ANODIC CHRONOPOTENTIOMETRY WITH PLATINUM AND GOLD ELECTRODES - THE IODIDE-IODINE-IODATE SYSTEM [J].
ANSON, FC ;
LINGANE, JJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1957, 79 (05) :1015-1020
[7]   Determination of iodide in urine by ion-pair chromatography with electrochemical detection [J].
Below, H ;
Kahlert, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (04) :431-436
[8]   VOLTAMMETRY OF IODINE(I) CHLORIDE IODINE AND IODATE AT ROTATED PLATINUM DISK AND RING-DISK ELECTRODES [J].
BERAN, P ;
BRUCKENS.S .
ANALYTICAL CHEMISTRY, 1968, 40 (07) :1044-&
[9]  
BRAININA KZ, 1966, ZH ANAL KHIM, V21, P1342
[10]   IODINE/IODIDE REDOX COUPLE AT A PLATINUM ELECTRODE [J].
DANE, LM ;
JANSSEN, LJJ ;
HOOGLAND, JG .
ELECTROCHIMICA ACTA, 1968, 13 (03) :507-&