Release of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Model

被引:47
作者
Bajgrowicz, Magdalena [1 ]
Chau-Minh Phan [2 ]
Subbaraman, Lakshman N. [2 ]
Jones, Lyndon [2 ]
机构
[1] Wroclaw Univ Technol, Dept Mech Mat Sci & Engn, PL-50370 Wroclaw, Poland
[2] Sch Optometry & Vis Sci, Ctr Contact Lens Res, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ciprofloxacin; moxifloxacin contact lens; drug delivery; eye model; microfluidic; silicone hydrogel; SILICONE HYDROGEL; DRUG-DELIVERY; FLUOROQUINOLONES; DEXAMETHASONE; RESISTANCE;
D O I
10.1167/iovs.15-16379
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To analyze the release of two fluoroquinolones, ciprofloxacin and moxifloxacin, from conventional hydrogel (CH) and silicone hydrogel (SH) daily disposable contact lenses (CLs), comparing release from a fixed-volume vial and a novel in vitro eye model. METHODS. Four CH CLs (nelfilcon A, omafilcon A, etafilcon A, ocufilcon B) and three SH CLs (somofilcon A, narafilcon A, delefilcon A) were used. The lenses were incubated in drug solutions for 24 hours. After the incubation period, the lenses were placed in two release conditions: (1) a vial containing 4.8 mL PBS for 24 hours and (2) an in vitro eye model with a flow rate at 4.8 mL over 24 hours. RESULTS. Release in the vial for both drugs was rapid, reaching a plateau between 15 minutes and 2 hours for all lenses. In contrast, under physiological flow conditions, a constant and slow release was observed over 24 hours. The amounts of ciprofloxacin released from the lenses ranged between 49.6 +/- 0.7 and 62.8 +/- 0.3 mu g per lens in the vial, and between 35.0 +/- 7.0 and 109.0 +/- 5.0 mu g per lens in the eye model. Moxifloxacin release ranged from 24.0 +/- 4.0 to 226.0 +/- 2.0 mu g per lens for the vial, and between 13.0 +/- 2.0 and 151.0 +/- 10.0 mu g per lens in the eye model. In both systems and for both drugs, HEMA-based CLs released more drugs than other materials. CONCLUSIONS. The parameters of the release system, in particular the volume and flow rate, have a significant influence on measured release profiles. Under physiological flow, release profiles are significantly slower and constant when compared with release in a vial.
引用
收藏
页码:2234 / 2242
页数:9
相关论文
共 34 条
[1]   Zero-order therapeutic release from imprinted hydrogel contact lenses within in vitro physiological ocular tear flow [J].
Ali, Maryarn ;
Horikawa, Shin ;
Venkatesh, Siddarth ;
Saha, Jishnu ;
Hong, Jong Wook ;
Byrne, Mark E. .
JOURNAL OF CONTROLLED RELEASE, 2007, 124 (03) :154-162
[2]  
Ambroziak Anna M, 2004, Eye Contact Lens, V30, P63, DOI 10.1097/01.ICL.0000105563.54932.44
[3]   Uptake and Release of Dexamethasone Phosphate From Silicone Hydrogel and Group I, II, and IV Hydrogel Contact Lenses [J].
Boone, Adrienne ;
Hui, Alex ;
Jones, Lyndon .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (05) :260-267
[4]   Fluoroquinolones in the treatment of bacterial keratitis [J].
Bower, KS ;
Kowalski, RP ;
Gordon, YJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 121 (06) :712-715
[5]   In Vitro Uptake and Release of Natamycin From Conventional and Silicone Hydrogel Contact Lens Materials [J].
Chau-Minh Phan ;
Subbaraman, Lakshman N. ;
Jones, Lyndon .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (02) :162-168
[6]   DROP SIZE AND INITIAL DOSING FREQUENCY PROBLEMS OF TOPICALLY APPLIED OPHTHALMIC DRUGS [J].
CHRAI, SS ;
MAKOID, MC ;
ERIKSEN, SP ;
ROBINSON, JR .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1974, 63 (03) :333-338
[7]   In vitro activity of fluoroquinolones against ocular bacterial isolates in Sao Paulo, Brazil [J].
Dourado Oliveira, Adalia Dias ;
Alves d'Azevedo, Pedro ;
Francisco, Waldemar ;
Hoefling-Lima, Ana Luisa .
CORNEA, 2007, 26 (02) :194-198
[8]  
FURUKAWA RE, 1978, AM J OPTOM PHYS OPT, V55, P69
[9]   About the effect of eye blinking on drug release from pHEMA-based hydrogels: an in vitro study [J].
Galante, R. ;
Paradiso, P. ;
Moutinho, M. G. ;
Fernandes, A. I. ;
Mata, J. L. G. ;
Matos, A. P. A. ;
Colaco, R. ;
Saramago, B. ;
Serro, A. P. .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2015, 26 (04) :235-251
[10]   Ophthalmic drug delivery through contact lenses [J].
Gulsen, D ;