Subcutaneous implantable cardioverter-defibrillator and defibrillation testing: A propensity-matched pilot study

被引:15
|
作者
Forleo, Giovanni B. [1 ]
Gasperetti, Alessio [1 ,2 ,3 ]
Breitenstein, Alexander [4 ]
Laredo, Mikael [5 ]
Schiavone, Marco [1 ]
Ziacchi, Matteo [6 ]
Vogler, Julia [7 ]
Ricciardi, Danilo [8 ]
Palmisano, Pietro [9 ]
Piro, Agostino [10 ]
Compagnucci, Paolo [2 ]
Waintraub, Xavier [5 ]
Mitacchione, Gianfranco [11 ]
Carrassa, Gianmarco [12 ]
Russo, Giulia [13 ]
De Bonis, Silvana [14 ]
Angeletti, Andrea [6 ]
Bisignani, Antonio [14 ]
Picarelli, Francesco [8 ]
Casella, Michela [2 ]
Bressi, Edoardo [15 ]
Rovaris, Giovanni [16 ]
Calo, Leonardo [15 ]
Santini, Luca [17 ]
Pignalberi, Carlo [18 ]
Lavalle, Carlo [10 ]
Viecca, Maurizio [1 ]
Pisano, Ennio [13 ]
Olivotto, Iacopo [12 ]
Curnis, Antonio [11 ]
Dello Russo, Antonio [2 ]
Tondo, Claudio [19 ,20 ]
Love, Charles J. [3 ]
Di Biase, Luigi [21 ]
Steffel, Jan [4 ]
Tilz, Roland [7 ]
Badenco, Nicolas [5 ]
Biffi, Mauro [6 ]
机构
[1] Luigi Sacco Univ Hosp, Cardiol Unit, Milan, Italy
[2] Univ Hosp Umberto I Salesi Lancisi, Cardiol & Arrhythmol Clin, Ancona, Italy
[3] Johns Hopkins Univ, Div Cardiol, Baltimore, MD USA
[4] Zurich Univ Hosp, Cardiol Dept, Zurich, Switzerland
[5] Hop La Pitie Salpetriere, AP HP, Paris, France
[6] Univ Bologna, St Orsola Hosp, Cardiol Unit, Bologna, Italy
[7] Univ Hosp Lubeck, Cardiol Dept, Lubeck, Germany
[8] Campus Biomed, Cardiol Dept, Rome, Italy
[9] Tricase Hosp, Cardiol Dept, Tricase, Italy
[10] Policlin Umberto 1, Cardiol Dept, Rome, Italy
[11] Spedali Civili Brescia, Cardiol Dept, Brescia, Italy
[12] Careggi Univ Hosp, Cardiomyopathy Unit, Florence, Italy
[13] Vito Fazzi Hosp, Cardiol Dept, Lecce, Italy
[14] Ferrari Hosp, Cardiol Dept, Cosenza, Italy
[15] Policlin Casilino, Cardiol Dept, Rome, Italy
[16] San Gerardo Hosp, Cardiol Dept, Monza, Italy
[17] Osped GB Grassi, Cardiol Dept, Ostia, Italy
[18] Osped San Filippo Neri, Cardiol Dept, Rome, Italy
[19] Univ Milan, Dept Biomed Surg & Dent Sci, Milan, Italy
[20] Ctr Cardiol Monzino IRCCS, Dept Clin Electrophysiol & Cardiac Pacing, Milan, Italy
[21] Montefiore Med Ctr, Albert Einstein Coll Med, Bronx, NY 10467 USA
关键词
Defibrillation testing; PRAETORIAN score; Propensity matching; Subcutaneous implantable cardioverter-defibrillator; Sudden cardiac death; VENTRICULAR DEFIBRILLATION; EFFICACY;
D O I
10.1016/j.hrthm.2021.06.1201
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND To date, only a few comparisons between subcutaneous implantable cardioverter-defibrillator (S-ICD) patients undergoing and those not undergoing defibrillation testing (DT) at implantation (DT+ vs DT-) have been reported. OBJECTIVE The purpose of this study was to compare long-term clinical outcomes of 2 propensity-matched cohorts of DT+ and DT- patients. METHODS Among consecutive S-ICD patients implanted across 17 centers from January 2015 to October 2020, DT-patients were 1:1 propensity-matched for baseline characteristics with DT+ patients. The primary outcome was a composite of ineffective shocks and cardiovascular mortality. Appropriate and inappropriate shock rates were deemed secondary outcomes. RESULTS Among 1290 patients, a total of 566 propensity-matched patients (283 DT+; 283 DT-) served as study population. Over median follow-up of 25.3 months, no significant differences in primary outcome event rates were found (10 DT+ vs 14 DT-; P =.404) as well as for ineffective shocks (5 DT- vs 3 DT+; P =.725). At multivariable Cox regression analysis, DT performance was associated with a reduction of neither the primary combined outcome nor ineffective shocks at follow-up. A high PRAETORIAN score was positively associated with both the primary outcome (hazard ratio 3.976; confidence interval 1.339-11.802; P =.013) and ineffective shocks alone at follow-up (hazard ratio 19.030; confidence interval 4.752-76.203; P =.003). CONCLUSION In 2 cohorts of strictly propensity-matched patients, DT performance was not associated with significant differences in cardiovascular mortality and ineffective shocks. The PRAETORIAN score is capable of correctly identifying a large percentage of patients at risk for ineffective shock conversion in both cohorts.
引用
收藏
页码:2072 / 2079
页数:8
相关论文
共 50 条
  • [1] Defibrillation testing of the subcutaneous implantable cardioverter-defibrillator at the time of generator replacement
    Schaller, Robert D.
    Hyman, Matthew
    Supple, Gregory E.
    Santangeli, Pasquale
    Riley, Michael P.
    Nazarian, Saman
    Arkles, Jeffrey
    Garcia, Fermin
    Lin, David
    Guandalini, Gustavo
    Kumareswaran, Ramanan
    Deo, Rajat
    Bode, Weeranun
    Markman, Timothy
    Epstein, Andrew
    Callans, David J.
    Dixit, Sanjay
    Brozoski, Joseph
    Marchlinski, Francis E.
    Frankel, David S.
    HEART RHYTHM, 2024, 21 (01) : 117 - 118
  • [2] Defibrillation testing during implantation of the subcutaneous implantable cardioverter-defibrillator: a necessary standard or becoming redundant?
    van der Stuijt, W.
    Quast, A. B. E.
    Knops, R. E.
    NETHERLANDS HEART JOURNAL, 2020, 28 (SUPPL 1) : 122 - 127
  • [3] Defibrillation testing during implantation of the subcutaneous implantable cardioverter-defibrillator: a necessary standard or becoming redundant?
    W. van der Stuijt
    A. B. E. Quast
    R. E. Knops
    Netherlands Heart Journal, 2020, 28 : 122 - 127
  • [4] Successful defibrillation testing in patients undergoing elective subcutaneous implantable cardioverter-defibrillator generator replacement
    de Veld, Jolien A.
    Pepplinkhuizen, Shari
    van der Stuijt, Willeke
    Quast, Anne-Floor B. E.
    Nordkamp, Louise R. A. Olde
    Kooiman, Kirsten M.
    Wilde, Arthur A. M.
    Smeding, Lonneke
    Knops, Reinoud E.
    EUROPACE, 2023, 25 (07):
  • [5] Intraoperative Defibrillation Testing of Subcutaneous Implantable Cardioverter-Defibrillator Systems-A Simple Issue?
    Frommeyer, Gerrit
    Zumhagen, Sven
    Dechering, Dirk G.
    Larbig, Robert
    Bettin, Markus
    Loeher, Andreas
    Koebe, Julia
    Reinke, Florian
    Eckardt, Lars
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (03):
  • [6] The subcutaneous implantable cardioverter-defibrillator
    Grace, Andrew
    CURRENT OPINION IN CARDIOLOGY, 2014, 29 (01) : 10 - 19
  • [7] Clinical impact of defibrillation testing at the time of implantable cardioverter-defibrillator insertion
    Hadid, Claudio
    Atienza, Felipe
    Strasberg, Boris
    Arenal, Angel
    Codner, Pablo
    Gonzalez-Torrecilla, Esteban
    Datino, Tomas
    Percal, Tamara
    Almendral, Jesus
    Ortiz, Mercedes
    Martins, Raphael
    Martinez-Alzamora, Nieves
    Fernandez Aviles, Francisco
    CARDIOLOGY JOURNAL, 2015, 22 (03) : 253 - 259
  • [8] Defibrillation testing is mandatory in patients with subcutaneous implantable cardioverter-defibrillator to confirm appropriate ventricular fibrillation detection
    de Waroux, Jean-Benoit le Polain
    Ploux, Sylvain
    Mondoly, Pierre
    Eschalier, Romain
    Strik, Marc
    Houard, Laura
    Pierre, Bertrand
    Buliard, Samuel
    Klotz, Nicolas
    Ritter, Philippe
    Haissaguerre, Michel
    Mahfouz, Karim
    Bordachar, Pierre
    HEART RHYTHM, 2018, 15 (05) : 642 - 650
  • [9] The subcutaneous implantable cardioverter-defibrillator in review
    Kamp, Nicholas J.
    Al-Khatib, Sana M.
    AMERICAN HEART JOURNAL, 2019, 217 : 131 - 139
  • [10] Propensity score matched comparison of subcutaneous and transvenous implantable cardioverter-defibrillator therapy in the SIMPLE and EFFORTLESS studies
    Brouwer, Tom F.
    Knops, Reinoud E.
    Kutyifa, Valentina
    Barr, Craig
    Mondesert, Blandine
    Boersma, Lucas V. A.
    Lambiase, Pier D.
    Wold, Nicholas
    Jones, Paul W.
    Healey, Jeffrey S.
    EUROPACE, 2018, 20 : F240 - F248