Evaluation of Combined Use of Transcranial and Direct Cortical Motor Evoked Potential Monitoring During Unruptured Aneurysm Surgery

被引:38
作者
Motoyama, Yasushi [1 ]
Kawaguchi, Masahiko [2 ]
Yamada, Shuichi [1 ]
Nakagawa, Ichiro [1 ]
Nishimura, Fumihiko [1 ]
Hironaka, Yasuo [1 ]
Park, Young-Su [1 ]
Hayashi, Hironobu [2 ]
Abe, Ryuichi [2 ]
Nakase, Hiroyuki [1 ]
机构
[1] Nara Med Univ, Dept Neurosurg, Nara 6348522, Japan
[2] Nara Med Univ, Dept Anesthesiol, Nara 6348522, Japan
关键词
motor evoked potential; direct cortical stimulation; transcranial electrical stimulation; cerebral aneurysm; intraoperative monitoring; BLOOD-FLOW INSUFFICIENCY; MIDDLE CEREBRAL-ARTERY; TEMPORARY OCCLUSION; GENERAL-ANESTHESIA; STIMULATION; LIMITATION; CORTEX; TIME;
D O I
10.2176/nmc.51.15
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The feasibility and reliability of combined use of transcranial and direct cortical motor evoked potential (MEP) monitoring during unruptured aneurysm surgery were evaluated. Forty-eight patients with unruptured cerebral aneurysms underwent craniotomy and neck clipping accompanied by muscle MEP monitoring. MEPs were elicited successfully by transcranial electrical stimulation in all patients. Direct cortical stimulation elicited MEPs in 44 patients. Reduction in MEP amplitude to less than 50% of baseline was considered significant. No postoperative motor paresis occurred in 39 patients in whom transcranial and direct MEPs remained unchanged. Four patients in whom direct MEPs could not be recorded had no intraoperative abnormality in transcranial MEPs and no postoperative motor dysfunction. Four of the other 5 patients manifested significant transient direct MEP changes without transcranial MEP changes. The transient MEP changes were observed in 3 patients during temporary clipping of the parent artery and in one patient with inadequate clipping of an middle cerebral artery aneurysm, and were considered due to insufficiency of blood flow. Decrease or disappearance of direct MEP waves recovered immediately after re-application of the clip and release of the temporary clip. Direct MEP waves disappeared and did not recover until the end of microsurgical procedures in one patient, although transcranial MEP amplitude remained at less than 50% of baseline. She developed hemiparesis postoperatively, which recovered within 6 hours. The duration of temporary occlusion in patients with direct MEP changes was significantly longer than that in patients without (p < 0.05). Direct MEP was sensitive in detecting ischemic stress to descending motor pathways during aneurysm surgery. Transcranial MEPs could be elicited in patients in whom direct MEPs could not be obtained, and during periods such as craniotomy or after dural closure, in which direct MEPs could not be recorded. These findings suggest that combined transcranial and direct cortical MEP recording may improve the feasibility and reliability of MEP monitoring during unruptured aneurysm surgery.
引用
收藏
页码:15 / 22
页数:8
相关论文
共 16 条
  • [1] Evaluation of Reliability of Post-Tetanic Motor-Evoked Potential Monitoring During Spinal Surgery Under General Anesthesia
    Hayashi, Hironobu
    Kawaguchi, Masahiko
    Yamamoto, Yuri
    Inoue, Satoki
    Koizumi, Munehisa
    Ueda, Yurito
    Takakura, Yoshinori
    Furuya, Hitoshi
    [J]. SPINE, 2008, 33 (26) : E994 - E1000
  • [2] Intraoperative monitoring of blood flow insufficiency during surgery of middle cerebral artery aneurysms
    Horiuchi, K
    Suzuki, K
    Sasaki, T
    Matsumoto, M
    Sakuma, J
    Konno, Y
    Oinuma, M
    Itakura, T
    Kodama, N
    [J]. JOURNAL OF NEUROSURGERY, 2005, 103 (02) : 275 - 283
  • [3] CORTICOSPINAL DIRECT RESPONSE IN HUMANS - IDENTIFICATION OF THE MOTOR CORTEX DURING INTRACRANIAL SURGERY UNDER GENERAL-ANESTHESIA
    KATAYAMA, Y
    TSUBOKAWA, T
    MAEJIMA, S
    HIRAYAMA, T
    YAMAMOTO, T
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1988, 51 (01) : 50 - 59
  • [4] Intraoperative myogenic motor evoked potentials induced by direct electrical stimulation of the exposed motor cortex under isoflurane and sevoflurane
    Kawaguchi, M
    Sakamoto, T
    Ohnishi, H
    Shimizu, K
    Karasawa, J
    Furuya, H
    [J]. ANESTHESIA AND ANALGESIA, 1996, 82 (03) : 593 - 599
  • [5] Kothbauer K F, 1998, Neurosurg Focus, V4, pe1
  • [6] Temporary occlusion of the middle cerebral artery in intracranial aneurysm surgery: time limitation and advantage of brain protection
    Lavine, SD
    Masri, LS
    Levy, ML
    Giannotta, SL
    [J]. JOURNAL OF NEUROSURGERY, 1997, 87 (06) : 817 - 824
  • [7] MIZOI K, 1993, NEUROSURGERY, V33, P434
  • [8] Monitoring of motor evoked potentials compared with somatosensory evoked potentials and microvascular Doppler ultrasonography in cerebral aneurysm surgery
    Neuloh, G
    Schramm, J
    [J]. JOURNAL OF NEUROSURGERY, 2004, 100 (03) : 389 - 399
  • [9] LIMITATION OF TEMPORARY VASCULAR OCCLUSION DURING ANEURYSM SURGERY - STUDY BY INTRAOPERATIVE MONITORING OF CORTICAL BLOOD-FLOW
    OGAWA, A
    SATO, H
    SAKURAI, Y
    YOSHIMOTO, T
    [J]. SURGICAL NEUROLOGY, 1991, 36 (06): : 453 - 457
  • [10] Temporary vessel occlusion for aneurysm surgery: Risk factors for stroke in patients protected by induced hypothermia and hypertension and intravenous mannitol administration
    Ogilvy, CS
    Carter, BS
    Kaplan, S
    Rich, C
    Crowell, RM