Results of Pericardial Patches in Tricuspid and Bicuspid Aortic Cusp Repair

被引:35
作者
Karliova, Irem [1 ]
Schneider, Ulrich [1 ]
Ehrlich, Tristan [1 ]
Schaefers, Hans-Joachim [1 ]
机构
[1] Saarland Univ, Dept Thorac & Cardiovasc Surg, Med Ctr, Kirrberger Str 100, D-66421 Homburg, Germany
关键词
AUTOLOGOUS PERICARDIUM; SUTURE ANNULOPLASTY; VALVE-REPLACEMENT; REGURGITATION; EXPERIENCE; IMPROVES; ROOT;
D O I
10.1016/j.athoracsur.2019.07.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Aortic valve repair for aortic regurgitation has become an increasingly accepted alternative to replacement. Some cusp pathologies require partial cusp replacement or augmentation using pericardium. There are limited data on pericardial patch durability. We analyzed our long-term results with pericardial patches in aortic cusp repair to clarify whether durability is influenced by aortic valve morphology or underlying cusp pathology. Methods. From 2000 to 2017, 275 patients (mean age, 53 +/- 14 years) underwent aortic valve repair involving pericardial patches with tricuspid aortic valve (n = 139, 50.5%) or bicuspid aortic valve (n = 136, 49.5%) morphology. Pericardial patches were used for either central cusp replacement (n = 64, 23%), closure of defects (n = 55, 20%), fenestrations (n = 104, 38%), cusp augmentation (n = 27, 10%), or commissural reconstruction (n = 25, 9%). Follow-up was complete in 96%. Results. Ten-year survival was 85%, and 10-year freedom from reoperation was 53%. Durability was inferior after bicuspid aortic valve repair (37%) compared with tricuspid aortic valve repair (69%; P< .0001). Best 10-year freedom from reoperation was found after closure of fenestrations (73%) and defects (67%). Suboptimal durability was observed after cusp augmentation (44%), central cusp replacement (39%), and commissural reconstruction (16%, P< .001). Conclusions. The results of aortic cusp repair using pericardium depend on valve morphology and cusp pathology. Mid- and long-term durability is reasonable in tricuspid aortic valve repair. In bicuspid aortic valve repair valve stability is poor regardless of cusp pathology and repair technique. For any analysis of patch durability, details of pathology and technique have to be considered. (C) 2020 by The Society of Thoracic Surgeons
引用
收藏
页码:728 / 735
页数:8
相关论文
共 25 条
[1]   Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic Valve [J].
Aicher, Diana ;
Kunihara, Takashi ;
Abou Issa, Omar ;
Brittner, Brigitte ;
Graeber, Stefan ;
Schaefers, Hans-Joachim .
CIRCULATION, 2011, 123 (02) :178-185
[2]   Aortic root and cusp configuration determine aortic valve function [J].
Bierbach, Benjamin Oliver ;
Aicher, Diana ;
Abu Issa, Omar ;
Bomberg, Hagen ;
Graeber, Stefan ;
Glombitza, Petra ;
Schaefers, Hans-Joachim .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (04) :400-406
[3]  
Cabrol C, 1966, Arch Mal Coeur Vaiss, V59, P1305
[4]   Valve repair improves the outcome of surgery for chronic severe aortic regurgitation: A propensity score analysis [J].
de Meester, Christophe ;
Pasquet, Agnes ;
Gerber, Bernhard L. ;
Vancraeynest, David ;
Noirhomme, Philippe ;
El Khoury, Gebrine ;
Vanoverschelde, Jean-Louis J. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (05) :1913-1920
[5]   AORTIC-VALVE REPLACEMENT WITH AUTOLOGOUS PERICARDIUM - SURGICAL TECHNIQUE [J].
DURAN, CMG ;
GALLO, R ;
KUMAR, N .
JOURNAL OF CARDIAC SURGERY, 1995, 10 (01) :1-9
[6]   Treated bovine and autologous pericardium for aortic valve reconstruction [J].
Duran, CMG ;
Gometza, B ;
Shahid, M ;
Al-Halees, Z .
ANNALS OF THORACIC SURGERY, 1998, 66 (06) :S166-S169
[7]   European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 1: aortic and pulmonary regurgitation (native valve disease) [J].
Lancellotti, Patrizio ;
Tribouilloy, Christophe ;
Hagendorff, Andreas ;
Moura, Luis ;
Popescu, Bogdan A. ;
Agricola, Eustachio ;
Monin, Jean-Luc ;
Pierard, Luc A. ;
Badano, Luigi ;
Zamorano, Jose L. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (03) :223-244
[8]   Valve-preserving aortic replacement:: Does the additional repair of leaflet prolapse adversely affect the results? [J].
Langer, F ;
Graeter, T ;
Nikoloudakis, N ;
Aicher, D ;
Wandler, O ;
Schäfers, HJ .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (02) :270-277
[9]  
LANGER F, 2004, CIRCULATION, V110, pI167
[10]  
Matsushima S, 2019, INDIAN J THORAC CARD