共 50 条
Validation of the assay of metoprolol in human plasma using liquid-liquid extraction and high performance liquid chromatography with fluorescence detection
被引:0
作者:
Farca, A
Tache, F
Medvedovici, A
David, V
机构:
[1] Univ Bucharest, Fac Chem, Dept Analyt Chem, Bucharest, Romania
[2] Labormed Pharma SA, Analyt Control Lab, Bucharest 6, Romania
来源:
CHEMIA ANALITYCZNA
|
2003年
/
48卷
/
04期
关键词:
metoprolol;
human plasma;
liquid-liquid extraction;
HPLC;
FLD;
validation;
D O I:
暂无
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Metoprolol was successfully assayed in human plasma samples. The sample preparation procedure was based upon liquid-liquid extraction, using propranolol as internal standard (I.S.). The HPLC procedure developed using a Merck Chromolith column was based on the ion pairing separation mechanism. Fluorescence detection (ex. 230 nm; em. 305 nm) provided an excellent delectability (the determined quantitation limit, LOQ was 7.5 ng mL(-1)). Both sample preparation and chromatographic procedure were validated and used in a single-dose comparative bioequivalence study carried out on thirteen healthy volunteers. The same column was used for the entire determination and no major alteration of the separation behaviour was observed.
引用
收藏
页码:677 / 688
页数:12