Solvent-processible polymer membrane-based liquid junction-free reference electrode

被引:68
作者
Lee, HJ [1 ]
Hong, US [1 ]
Lee, DK [1 ]
Shin, JH [1 ]
Nam, H [1 ]
Cha, GS [1 ]
机构
[1] Kwangwoon Univ, Dept Chem, Nowon Ku, Seoul 139701, South Korea
关键词
D O I
10.1021/ac980265k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of liquid junction;free reference electrode system is devised by employing solvent-processible polymer membranes. The membranes are formulated with either a one-component silicone rubber or an aromatic-type polyurethane as the matrixes. The optimized formulations incorporate both cation- and anion-exchange sites (i.e,, potassium tetrakis(p-chlorophenyl)borate and tridodecylmethylammonium chloride) and; in the case of silicone rubber, a plasticizer. The silicone rubber-based membrane, while possessing minimal response toward most ions, is found to display a near-Nernstian response to pH change. The aromatic polyurethane matrix formulation, however; is not sensitive to pH over a wide range (i.e,, pH 2-12) and is shown to exhibit only a small emf variation (within +/-2 mV) toward a wide variety of salts added even at very high concentrations (i,e,, up to 0.1 M). Potentiometric emf responses of ISEs (e.g,, Na+, K+, Ca2+, Cl-), whether paired with a polymer membrane-based reference electrode or with a conventional liquid junction-type reference electrode, are shown to be remarkably similar within the precision of the measurement setup. The feasibility of adapting the proposed reference electrode to the planar solid-state sensor format is also demonstrated.
引用
收藏
页码:3377 / 3383
页数:7
相关论文
共 27 条
[1]   ELECTROCHEMICAL PERFORMANCE, BIOCOMPATIBILITY, AND ADHESION OF NEW POLYMER MATRICES FOR SOLID-STATE ION SENSORS [J].
CHA, GS ;
LIU, D ;
MEYERHOFF, ME ;
CANTOR, HC ;
MIDGLEY, AR ;
GOLDBERG, HD ;
BROWN, RB .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1666-1672
[2]   SENSITIZATION OF DIELECTRIC SURFACES BY CHEMICAL GRAFTING - APPLICATION TO PH ISFETS AND REFETS [J].
CHOVELON, JM ;
FOMBON, JJ ;
CLECHET, P ;
JAFFREZICRENAULT, N ;
MARTELET, C ;
NYAMSI, A ;
CROS, Y .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 8 (03) :221-225
[3]   Aliphatic polyurethane as a matrix for pH sensors: Effects of native sites and added proton carrier on electrical and potentiometric properties [J].
Cosofret, VV ;
Erdosy, M ;
Raleigh, JS ;
Johnson, TA ;
Neuman, MR ;
Buck, RP .
TALANTA, 1996, 43 (01) :143-151
[4]   EVALUATION OF A NEW SOLID-STATE REFERENCE ELECTRODE JUNCTION MATERIAL FOR ION-SELECTIVE ELECTRODES [J].
DIAMOND, D ;
MCENROE, E ;
MCCARRICK, M ;
LEWENSTAM, A .
ELECTROANALYSIS, 1994, 6 (11-12) :962-971
[5]  
*FLUK CHEM AG, 1991, FLUK SEL CAT
[6]   CHEMICALLY MODIFIED PARYLENE GATE FIELD-EFFECT TRANSISTORS - PREPARATION OF PH INSENSITIVE PARYLENE GATE FOR CHEMICAL MODIFICATION [J].
FUJIHIRA, M ;
FUKUI, M ;
OSA, T .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 106 (1-2) :413-418
[7]   New solvent system for the improved electrochemical performance of screen-printed polyurethane membrane-based solid-state sensors [J].
Hower, RW ;
Shin, JH ;
Cha, GS ;
Meruva, RK ;
Meyerhoff, ME ;
Brown, RB .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) :168-172
[8]   ION-SENSITIVE FIELD-EFFECT TRANSISTOR SENSORS WITH A COVALENTLY BOUND MONOLAYER MEMBRANE - EXAMPLE OF CALCIUM DETECTION [J].
JAFFREZICRENAULT, N ;
CHOVELON, JM ;
PERROT, H ;
LEPERCHEC, P ;
CHEVALIER, Y .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 5 (1-4) :67-70
[9]   A SOLID-STATE PH SENSOR-BASED ON A NAFION-COATED IRIDIUM OXIDE INDICATOR ELECTRODE AND A POLYMER-BASED SILVER-CHLORIDE REFERENCE ELECTRODE [J].
KINLEN, PJ ;
HEIDER, JE ;
HUBBARD, DE .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 22 (01) :13-25
[10]   All-solid-state sodium-selective electrodes based on room temperature vulcanizing-type silicone rubber matrix [J].
Lee, HJ ;
Oh, HJ ;
Cui, G ;
Cha, GS ;
Nam, H .
ANALYTICAL SCIENCES, 1997, 13 :289-294