Complications of intrastromal corneal ring segment implantation using a femtosecond laser for channel creation: a survey of 850 eyes with keratoconus

被引:87
作者
Coskunseven, Efekan [2 ]
Kymionis, George D.
Tsiklis, Nikolaos S. [1 ]
Atun, Serife [2 ]
Arslan, Ebru [2 ]
Siganos, Charalambos S.
Jankov, Mirco [3 ]
Pallikaris, Ioannis G.
机构
[1] Univ Crete, Dept Ophthalmol, Inst Vis & Opt, Sch Med, Iraklion 71003, Crete, Greece
[2] Dunya Eye Hosp, Istanbul, Turkey
[3] Med Acad US Med Sch, Milos Klin, Belgrade, Serbia
关键词
femtosecond laser; intrastromal corneal ring segments; keratoconus; TERM-FOLLOW-UP; INTACS; MANAGEMENT; EFFICACY; ECTASIA;
D O I
10.1111/j.1755-3768.2009.01605.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report complications after the implantation of intrastromal corneal ring segments (Keraring; Mediphacos, Belo Horizonte, Brazil) in keratoconic eyes using a femtosecond laser (IntraLase; Advanced Medical Optics, Santa Ana, California, USA) for channel creation. Methods: Retrospective chart review of 531 patients (850 eyes) who underwent Keraring insertion using a femtosecond laser for channel creation. Intraoperative and postoperative complications were recorded. Results: Intraoperatively, there were 22 (2.7%) cases of incomplete channel formation. The rest of the intraoperative complications were galvo lag error (system malfunction) [five eyes (0.6%)], endothelial perforation [five eyes (0.6%)] and incorrect entry of the channel [two eyes (0.2%)]. Postoperatively, there were 11 (1.3%) cases of segment migration, two (0.2%) cases of corneal melting and one (0.1%) case of mild infection. The overall complication rate was 5.7% (49 cases out of 850 eyes). Conclusion: In this study, intracorneal ring segment implantation using a femtosecond laser for channel creation was related to a number of complications. The most common complications were incomplete channel creation (intraoperatively) and segment migration (postoperatively).
引用
收藏
页码:54 / 57
页数:4
相关论文
共 14 条
[1]   Intacs for keratoconus and Post-LASIK ectasia - Mechanical versus femtosecond laser-assisted channel creation [J].
Carrasquillo, Karen G. ;
Rand, Janet ;
Talamo, Jonathan H. .
CORNEA, 2007, 26 (08) :956-962
[2]   One-year results of intrastromal corneal ring segment implantation (KeraRing) using femtosecond laser in patients with keratoconus [J].
Coskunseven, Efekan ;
Kymionis, George D. ;
Tsiklis, Nikolaos S. ;
Atun, Serife ;
Arslan, Ebru ;
Jankov, Mirko R. ;
Pallikaris, Ioannis G. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (05) :775-779
[3]   Comparison of outcomes of 2 channel sizes for intrastromal ring segment implantation with a femtosecond laser in eyes with keratoconus [J].
Ertan, Aylin ;
Kamburoglu, Gunhal ;
Akguen, Uemit .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (04) :648-653
[4]   Topography-guided vertical implantation of intacs using a femtosecond laser for the treatment of keratoconus [J].
Ertan, Aylin ;
Bahadir, Mehmet .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) :148-151
[5]   Intacs insertion with the femtosecond laser for the management of keratoconus - One-year results [J].
Ertan, Aylin ;
Kamburoglu, Gunhal ;
Bahadir, Mehmet .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) :2039-2042
[6]   Modified intracorneal ring segment implantations (INTACS) for the management of moderate to advanced keratoconus - Efficacy and complications [J].
Kanellopoulos, AJ ;
Pe, LH ;
Perry, HD ;
Donnenfeld, ED .
CORNEA, 2006, 25 (01) :29-33
[7]   Long-term follow-up of intacs in keratoconus [J].
Kymionis, George D. ;
Siganos, Charalambos S. ;
Tsiklis, Nikolaos S. ;
Anastasakis, Anastasios ;
Yoo, Sonia H. ;
Pallikaris, Aristofanis I. ;
Astyrakakis, Nikolaos ;
Pallikaris, Ioannis G. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (02) :236-244
[8]   Long-term follow-up of intacs for post-LASIK corneal ectasia [J].
Kymionis, George D. ;
Tsiklis, Nikolaos S. ;
Pallikaris, Aristofanis I. ;
Kounis, George ;
Diakonis, Vasilios F. ;
Astyrakakis, Nikolaos ;
Siganos, Charalambos S. .
OPHTHALMOLOGY, 2006, 113 (11) :1909-1917
[9]  
Rabinowitz YS, 2006, J REFRACT SURG, V22, P764
[10]  
Ratkay-Traub I, 2003, J REFRACT SURG, V19, P94