Musculskeletal magnetic resonance imaging (MRI) applications are making the transition rapidly from 1.5 tesla (T) to 3T. The higher signal-to-noise ratio (SNR) that is available with a 3T MRI system allows for greater spatial resolution and provides the potential to improve the diagnostic capability of musculoskeletal MRI. With the use of 3T systems, one can enhance the SNR, spatial resolution, and contrast-to-noise ratio of intrinsic joint structures such as osseous, tendinous, cartilaginous, and ligamentous structures, which makes them more discernable and amenable to proper radiologic assessment. The SNR gain and coil technology advances allow for a smaller voxel-size and parallel imaging, reducing the acquisition time without significant signal loss. Three-dimensional (3D) fast spin echo sequences with isotropic resolution reduce partial volume artifacts through the acquisition of thin continuous sections and enable free 3D-multi-planar-reformatting without loss of image quality. This technique may be a promising method to replace currently used 2D sequences in clinical practice. In addition to current clinical applications, 3T MRI will contribute to the development of new molecular and functional MRI techniques.
引用
收藏
页码:1074 / 1085
页数:12
相关论文
共 58 条
[1]   Accuracy of MRI patterns in evaluating anterior cruciate ligament tears [J].
Barry, KP ;
Mesgarzadeh, M ;
Triolo, J ;
Moyer, R ;
Tehranzadeh, J ;
Bonakdarpour, A .
SKELETAL RADIOLOGY, 1996, 25 (04) :365-370
[2]   Superior labrum anterior-posterior lesions: Diagnosis with MR arthrography of the shoulder [J].
Bencardino, JT ;
Beltran, J ;
Rosenberg, ZS ;
Rokito, A ;
Schmahmann, S ;
Mota, J ;
Mellado, JM ;
Zuckerman, J ;
Cuomo, F ;
Rose, D .
RADIOLOGY, 2000, 214 (01) :267-271
[3]   The meniscal roots: Gross anatomic correlation with 3-T MRI findings [J].
Brody, Jeffrey M. ;
Hulstyn, Michael J. ;
Fleming, Braden C. ;
Tung, Glenn A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) :W446-W450
[4]   Noncontrast MR imaging and MR arthrography of the ulnar collateral ligament of the elbow: prospective evaluation of two-dimensional pulse sequences for detection of complete tears [J].
Carrino, JA ;
Morrison, WB ;
Zou, KH ;
Steffen, RT ;
Snearly, WN ;
Murray, PM .
SKELETAL RADIOLOGY, 2001, 30 (11) :625-632
[5]   MR imaging of the knee at 0.2 and 1.5 T:: Correlation with surgery [J].
Cotten, A ;
Delfaut, E ;
Demondion, X ;
Lapègue, F ;
Boukhelifa, M ;
Boutry, N ;
Chastanet, P ;
Gougeon, F .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :1093-1097
[6]   MR imaging of murine arthritis using ultrasmall superparamagnetic iron oxide particles [J].
Dardzinski, BJ ;
Schmithorst, VJ ;
Holland, SK ;
Boivin, GP ;
Imagawa, T ;
Watanabe, S ;
Lewis, JM ;
Hirsch, R .
MAGNETIC RESONANCE IMAGING, 2001, 19 (09) :1209-1216
[7]   ORIENTATION OF TENDONS IN THE MAGNETIC-FIELD AND ITS EFFECT ON T2 RELAXATION-TIMES [J].
FULLERTON, GD ;
CAMERON, IL ;
ORD, VA .
RADIOLOGY, 1985, 155 (02) :433-435
[8]   Driven equilibrium magnetic resonance imaging of articular cartilage: Initial clinical experience [J].
Gold, GE ;
Fuller, SE ;
Hargreaves, BA ;
Stevens, KJ ;
Beaulieu, CF .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :476-481
[9]   Musculoskeletal MRI at 3.0T: Relaxation times and image contrast [J].
Gold, GE ;
Han, E ;
Stainsby, J ;
Wright, G ;
Brittain, J ;
Beaulieu, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (02) :343-351
[10]   MAGNETIC-RESONANCE-IMAGING OF THE POSTERIOR CRUCIATE LIGAMENT - CLINICAL USE TO IMPROVE DIAGNOSTIC-ACCURACY [J].
GROSS, ML ;
GROVER, JS ;
BASSETT, LW ;
SEEGER, LL ;
FINERMAN, GAM .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (06) :732-737