To date there is no imaging modality for cardiac arrhythmias which remain the leading cause of sudden death in the United States (>300000/yr.). Electrocardiographic imaging (ECGI), a noninvasive modality that images cardiac arrhythmias from body surface potentials, requires the geometrical relationship between the heart surface and the positions of body surface ECG electrodes. A photographic method was validated in a mannequin and used to determine the three-dimensional coordinates of body surface ECG electrodes to within 1 mm of their actual positions. Since fluoroscopy is available in the cardiac electrophysiology (EP) laboratory where diagnosis and treatment of cardiac arrhythmias is conducted, a fluoroscopic method to determine the heart surface geometry was developed based on projective geometry, epipolar geometry, point reconstruction, b-spline interpolation and visualization. Fluoroscopy-reconstructed hearts in a phantom and a human subject were validated using high-resolution computed tomography (CT) imaging. The mean absolute distance error for the fluoroscopy-reconstructed heart relative to the CT heart was 4 mm (phantom) and 10 mm (human). In the human, ECGI images of normal cardiac electrical activity on the fluoroscopy-reconstructed heart showed close correlation with those obtained on the CT heart. Results demonstrate the feasibility of this approach for clinical noninvasive imaging of cardiac arrhythmias in the interventional EP laboratory.
引用
收藏
页码:1307 / 1318
页数:12
相关论文
共 37 条
[1]  
[Anonymous], 1993, Three-Dimensional Computer Vision: A Geometric Viewpoint
[2]   3D surface reconstruction using occluding contours [J].
Boyer, E ;
Berger, MO .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1997, 22 (03) :219-233
[3]  
Brebbia CA., 1984, BOUNDARY ELEMENT TEC, DOI DOI 10.1007/978-3-642-48860-3
[4]   A noninvasive imaging modality for cardiac arrhythmias [J].
Burnes, JE ;
Taccardi, B ;
Rudy, Y .
CIRCULATION, 2000, 102 (17) :2152-2158
[5]   Noninvasive ECG imaging of electrophysiologically abnormal substrates in infarcted hearts - A model study [J].
Burnes, JE ;
Taccardi, B ;
MacLeod, RS ;
Rudy, Y .
CIRCULATION, 2000, 101 (05) :533-540
[6]   Noninvasive electrocardiographic imaging of substrate and intramural ventricular tachycardia in infarcted hearts [J].
Burnes, JE ;
Taccardi, B ;
Ershler, PR ;
Rudy, Y .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (07) :2071-2078
[7]   Imaging dispersion of myocardial repolarization, I - Comparison of body-surface and epicardial measures [J].
Burnes, JE ;
Ghanem, RN ;
Waldo, AL ;
Rudy, Y .
CIRCULATION, 2001, 104 (11) :1299-1305
[8]   Improved determination of biplane imaging geometry from two projection images and its application to three-dimensional reconstruction of coronary arterial trees [J].
Chen, SYJ ;
Metz, CE .
MEDICAL PHYSICS, 1997, 24 (05) :633-654
[9]   The effect of image distortion on 3-D reconstruction of coronary bypass grafts from angiographic views [J].
Dorsaz, PA ;
Dorsaz, L ;
Doriot, PA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (07) :759-762
[10]   Evaluation of imaging geometries calculated from biplane images [J].
Esthappan, J ;
Harauchi, H ;
Hoffmann, KR .
MEDICAL PHYSICS, 1998, 25 (06) :965-975