Neurovascular risks of sacral screws with bicortical purchase: an anatomical study

被引:36
作者
Ergur, Ipek
Akcali, Omer
Kiray, Amac
Kosay, Can
Tayefi, Hamid
机构
[1] Dokuz Eylul Univ, Sch Med, Dept Orthoped & Traumatol, TR-35330 Izmir, Turkey
[2] Dokuz Eylul Univ, Sch Med, Dept Anat, Izmir, Turkey
关键词
sacral screw; spine surgery; anatomy; complication;
D O I
10.1007/s00586-007-0326-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The aim of this cadaver study is to define the anatomic structures on anterior sacrum, which are under the risk of injury during bicortical screw application to the S1 and S2 pedicles. Thirty formaldehyde-preserved human male cadavers were studied. Posterior midline incision was performed, and soft tissues and muscles were dissected from the posterior part of the lumbosacral region. A 6 mm pedicle screw was inserted between the superior facet of S1 and the S1 foramen. The entry point of the S2 pedicle screw was located between S1 and S2 foramina. S1 and S2 screws were placed on both right and the left sides of all cadavers. Then, all cadavers were turned into supine position. All abdominal and pelvic organs were moved away and carefully observed for any injury. The tips of the sacral screws were marked and the relations with the anatomic structures were defined. The position of the sacral screws relative to the middle and lateral sacral arteries and veins, and the sacral sympathetic trunk were measured. There was no injury to the visceral organs. In four cases, S1 screw tip was in direct contact with middle sacral artery. In two cases, S1 screw tip was in direct contact with middle sacral vein. It was observed that the S1 screw tips were in close proximity to sacral sympathetic trunk on both right and the left sides. The tip of the S2 screw was in contact with middle sacral artery on the left side only in one case. It is found that the tip of the S2 screw was closely located with the middle sacral vein in two cases. The tip of the S2 pedicle screw was in contact with the sacral sympathetic trunk in eight cases on the right side and seven cases on the left side. Lateral sacral vein was also observed to be disturbed by the S1 and S2 screws. As a conclusion, anterior cortical penetration during sacral screw insertion carries a risk of neurovascular injury. The risk of sacral sympathetic trunk and minor vascular structures together with the major neurovascular structures and viscera should be kept in mind.
引用
收藏
页码:1519 / 1523
页数:5
相关论文
共 20 条
  • [1] Anatomic considerations of the second sacral vertebra and dorsal screw placement
    Ebraheim, NA
    Lu, J
    Yang, H
    Heck, BE
    Yeasting, RA
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 1997, 19 (06) : 353 - 357
  • [2] Ebraheim NA, 2000, ORTHOPEDICS, V23, P245
  • [3] Outcome and complications of long Fusions to the Sacrum in adult spine deformity - Luque-galveston, combined iliac and sacral screws, and sacral fixation
    Emami, A
    Deviren, V
    Berven, S
    Smith, JA
    Hu, SS
    Bradford, DS
    [J]. SPINE, 2002, 27 (07) : 776 - 786
  • [4] Esenkaya Irfan, 2003, Acta Orthop Traumatol Turc, V37, P330
  • [5] ESSES SI, 1991, SPINE S, V16, P283
  • [6] Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations
    Jutte, PC
    Castelein, RM
    [J]. EUROPEAN SPINE JOURNAL, 2002, 11 (06) : 594 - 598
  • [7] Closed posterior superior iliac spine impeding pediculocorporeal S-1 screw insertion
    Kaptanoglu, E
    Okutan, O
    Tekdemir, I
    Beskonakli, E
    Deda, H
    [J]. JOURNAL OF NEUROSURGERY, 2003, 99 (02) : 229 - 234
  • [8] Krag MH, 1991, SPINE S, V16, p84s
  • [9] Biomechanical comparison of lumbosacral fixation techniques in a calf spine model
    Lebwohl, NH
    Cunningham, BW
    Dmitriev, A
    Shimamoto, N
    Gooch, L
    Devlin, V
    Boachie-Adjei, O
    Wagner, TA
    [J]. SPINE, 2002, 27 (21) : 2312 - 2320
  • [10] Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation - A biomechanical analysis
    Lehman, RA
    Kuklo, TR
    Belmont, PJ
    Andersen, RC
    Polly, DW
    [J]. SPINE, 2002, 27 (08) : 806 - 811