Optimal mixing rate in reverse phase liquid chromatography. Experimental evaluations

被引:9
作者
Desmet, Gert [1 ]
Pepermans, Vincent [1 ]
Broeckhoven, Ken [1 ]
Blumberg, Leonid M. [2 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn, Pl Laan 2, B-1050 Brussels, Belgium
[2] Advachrom, POB 1243, Wilmington, DE 19801 USA
关键词
Optimal mixing rate; Default mixing rate; Speed optimization criteria; Quadratic system; Quartic system; GRADIENT-ELUTION; SEPARATION PERFORMANCE; GAS-CHROMATOGRAPHY; SPEED; METRICS; PARAMETERS; TIME;
D O I
10.1016/j.chroma.2017.07.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The topic of this report is experimental verification of previously published theoretical predictions. The mixing rate (R-phi) is the temporal rate of increasing a fraction of stronger solvent in the mobile phase of gradient LC. The optimal R-phi (R-phi,(opt)) is the one at which a required peak capacity (n) of gradient LC analysis is obtained in the shortest time. The key factors affecting R-phi,(opt) are the sample molecular weight (M), the void time (t(M)), and the column pressure condition - R-phi,(opt) in a column operating below the instrumental pressure limit is 2-3 times higher than R-phi,(opt) in a column operating at the instrumental pressure limit. Using previously proposed speed optimization criteria, t/s(i), where t, s and i are the analysis time, the separation capacity (a metric proportions to n), and the order (i = 2 or i= 4 for analyses operating below or at the instrumental pressure limit, respectively), parameter R-phi,(opt) for analyses of small-molecule samples has been experimentally found. For both orders, the agreement with the theoretical prediction can be considered as very good. Base on the experimental results, we continue to recommend the earlier proposed theoretically based mixing rate of 5%/t(M) as a default for all analyses of small-molecule samples (100 < M < 400), and 50% root 3/M/t(M) for larger molecules. Experimental evidence is also provided to explain why earlier published less accurate equations for peak capacity and analysis time are not suitable for theoretical prediction of R-phi,(opt). (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:84 / 92
页数:9
相关论文
共 26 条
[1]  
Blumberg L.M., 2012, GAS CHROMATOGRAPHY, P19
[2]   Optimal mixing rate in linear solvent strength gradient liquid chromatography. Balanced mixing program [J].
Blumberg, Leonid M. ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1476 :35-45
[3]   Optimal Mixing Rate in Linear Solvent Strength Gradient Liquid Chromatography [J].
Blumberg, Leonid M. ;
Desmet, Gert .
ANALYTICAL CHEMISTRY, 2016, 88 (04) :2281-2288
[4]   Metrics of separation performance in chromatography Part 3: General separation performance of linear solvent strength gradient liquid chromatography [J].
Blumberg, Leonid M. ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1413 :9-21
[5]   Theory of Gradient Elution Liquid Chromatography with Linear Solvent Strength: Part 1. Migration and Elution Parameters of a Solute Band [J].
Blumberg, Leonid M. .
CHROMATOGRAPHIA, 2014, 77 (1-2) :179-188
[6]   Metrics of separation performance in chromatography. Part 1. Definitions and application to static analyses [J].
Blumberg, Leonid M. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (32) :5375-5385
[7]   Metrics of separation in chromatography [J].
Blumberg, LM ;
Klee, MS .
JOURNAL OF CHROMATOGRAPHY A, 2001, 933 (1-2) :1-11
[8]  
Blumberg LM, 2000, J MICROCOLUMN SEP, V12, P508, DOI 10.1002/1520-667X(2000)12:9<508::AID-MCS5>3.0.CO
[9]  
2-Y
[10]  
Blumberg LM, 1997, HRC-J HIGH RES CHROM, V20, P679