Comparison between two methods for cardiac output measurement in propofol-anesthetized dogs: thermodilution and Doppler

被引:26
作者
Ferro Lopes, Patricia Cristina [1 ]
Sousa, Marlos Goncalves [2 ]
Camacho, Aparecido Antonio [1 ]
Carareto, Roberta [2 ]
Nishimori, Celina T. D. [3 ]
Santos, Paulo S. P. [4 ]
Nunes, Newton [1 ]
机构
[1] Univ Estadual Paulista, Dept Vet Med & Surg, Vet Surg Postgrad Program, Coll Agr & Vet Sci, BR-14884900 Sao Paulo, Brazil
[2] Univ Fed Tocantins, Sch Vet Med & Zootecnia, Araguaina, Tocantins, Brazil
[3] Univ Franca, Anesthesiol & Vet Surg Postgrad Program, Sao Paulo, Brazil
[4] Univ Estadual Paulista, Dept Clin Surg & Anim Reprod, Coll Agr & Vet Sci, Sao Paulo, Brazil
关键词
anesthesia; cardiac output; dogs; echocardiography; ECHOCARDIOGRAPHY; AGREEMENT;
D O I
10.1111/j.1467-2995.2010.00552.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (COTD) and Doppler evaluation of pulmonary flow (CODP) and aortic flow (CODA). Study design Prospective cohort study. Animals Eight adult dogs weighing 8.3 +/- 2.0 kg. Methods Propofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CODP and CODA were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate COTD. The first measurement of COTD, CODP and CODA was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD. Results At T0, COTD was lower than CODA. CODA was higher than COTD and CODP at T30, T45 and T60. The difference between the COTD and CODP, when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the COTD and CODA was -0.87 +/- 0.54 L minute-1 and r = 0.69. For COTD and CODP, the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61. Conclusion Doppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.
引用
收藏
页码:401 / 408
页数:8
相关论文
共 27 条
[11]   Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients [J].
Gonzalez, J ;
Delafosse, C ;
Fartoukh, M ;
Capderou, A ;
Straus, C ;
Zelter, M ;
Derenne, JP ;
Similowski, T .
CRITICAL CARE, 2003, 7 (02) :171-178
[12]  
HAITES NE, 1984, LANCET, V2, P1025
[13]  
Haskins S, 2007, LUMB JONES VET ANEST, P86
[14]  
Hug CJ, 1989, TRATADO ANESTHESIA, P419
[15]  
Ilkiw J E, 2003, Vet Anaesth Analg, V30, P102, DOI 10.1046/j.1467-2995.2003.00133_8.x
[16]  
Kaneko J.J., 1997, Clinical Biochemistry Of Domestic Animals, V5, P932
[17]  
Kittleson MD, 1998, SMALL ANIMAL CARDIOVASCULAR MEDICINE, P118
[18]  
Lazic T, 2003, Vet Anaesth Analg, V30, P104, DOI 10.1046/j.1467-2995.2003.00133_12.x
[19]   THERMODILUTION CARDIAC-OUTPUT - CRITICAL ANALYSIS AND REVIEW OF THE LITERATURE [J].
LEVETT, JM ;
REPLOGLE, RL .
JOURNAL OF SURGICAL RESEARCH, 1979, 27 (06) :392-404
[20]   Assessment of lithium dilution cardiac output as a technique for measurement of cardiac output in dogs [J].
Mason, DJ ;
O'Grady, M ;
Woods, JP ;
McDonell, W .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2001, 62 (08) :1255-1261