Different cutoff values of Cyfra 21-1 for cavitary and noncavitary lung cancers

被引:8
作者
Kim, YC
Lim, SC
Bom, HS
Park, KO
Na, KJ
Park, HK
Hwang, JH
机构
[1] Chonnam Natl Univ, Sch Med, Dept Internal Med, Kwangju 501757, South Korea
[2] Chonnam Natl Univ, Sch Med, Dept Nucl Med, Kwangju 501757, South Korea
[3] Chonnam Natl Univ, Sch Med, Dept Thorac & Cardiovasc Surg, Kwangju 501757, South Korea
关键词
Cyfra; 21-1; cutoff values; lung cancer;
D O I
10.1016/S0169-5002(00)00134-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Study objectives: Cell lysis and tumor necrosis release cytokeratin, a tumor marker of lung cancer, into the serum. The serum cytokeratin level can also be elevated in benign cavitary lung diseases. The purpose of this study was to evaluate whether Cyfra 21-1 can differentiate malignant lung diseases from benign diseases with cavitary lesions. Design: This study is a retrospective review of the case records of patients with lung lesions seen during a 4-year period from January 1993 to May 1996. Setting and patients: Serum Cyfra 21-1 levels were measured in 306 patients with lung cancer (n = 143) or benign lung disease (n = 163). The patients were grouped according to radiologic evidence of cavitary lung lesions. Lung cancer included both non-small cell (n = 123) and small cell (n = 20) lung cancers, and the benign diseases include tuberculosis (n = 87), abscess (n =26), pneumonia (n =4), and others (n = 46). Measurements and results: Although Cyfra 21-1 clearly differentiated cavitary lung cancer (15.0, 9.1-29.8 ng/ml, median and interquartile range, n = 39) from benign cavitary disease (P < 0.001), and noncavitary lung cancer from benign noncavitary; disease (1.7, 0.9-2.6 ng/ml, n = 108, P < 0.001), it could not differentiate noncavitary lung cancer (5.0, 2.1-12.4 ng/ml, n = 104) from benign cavitary diseases (3.3, 1.4-8.3 ng/ml, n = 55, P = 0.45). Conclusions: Serum Cyfra 21-1 is a useful tumor marker for differentiating benign from malignant lung diseases. However, different cutoff values are needed, depending on the presence of cavitary lesions. We recommend cutoff values of 30 ng/ml for cavitary lung diseases and 6 ng/ml for noncavitary lung diseases. If there are no radiologic data, a cutoff value of 15 ng/ml is recommended. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 18 条
  • [1] [Anonymous], 1997, AM J RESP CRIT CARE, V156, P320
  • [2] [Anonymous], 1981, HIST TYP LUNG TUM
  • [3] BROERS JLV, 1988, CANCER RES, V48, P3221
  • [4] BROERS JLV, 1987, CANCER RES, V47, P3225
  • [5] A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1983, 148 (03) : 839 - 843
  • [6] THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1982, 143 (01) : 29 - 36
  • [7] Cyfra 21-1 in cavitary lung lesions
    Kim, YC
    Park, KO
    Choi, IS
    Lim, SC
    Bom, HS
    [J]. CHEST, 1996, 109 (03) : 856 - 856
  • [8] Kim Young-Chul, 1996, Korean Journal of Internal Medicine (English Edition), V11, P50
  • [9] CYFRA 21-1 enzyme-linked immunosorbent assay - Evaluation as a tumor marker in non-small cell lung cancer
    Lai, RS
    Hsu, HK
    Lu, JY
    Ger, LP
    Lai, NS
    [J]. CHEST, 1996, 109 (04) : 995 - 1000
  • [10] THE CATALOG OF HUMAN CYTOKERATINS - PATTERNS OF EXPRESSION IN NORMAL EPITHELIA, TUMORS AND CULTURED-CELLS
    MOLL, R
    FRANKE, WW
    SCHILLER, DL
    GEIGER, B
    KREPLER, R
    [J]. CELL, 1982, 31 (01) : 11 - 24