Particulate debris collected during carotid stenting: Are we missing something?

被引:2
作者
Cheng, W. Y. [1 ]
Stephens, M. [1 ]
Lin, B. P. C. [1 ]
Lowe, H. C. [1 ]
McMahon, A. C. [1 ]
机构
[1] Concord Hosp, Anzac Res Inst, Sydney, NSW, Australia
关键词
carotid; stent; distal protection;
D O I
10.1016/j.ijcard.2006.07.184
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Particulate and histopathologic examination of atherosclerotic material collected during carotid artery stenting is presented, illustrating the limitations of current knowledge regarding the use of distal protection devices (DPD) during this novel vascular intervention. Crown Copyright 0 2006 Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:277 / 279
页数:3
相关论文
共 7 条
[1]   Cerebral protection during carotid artery stenting -: Collection and histopathologic analysis of embolized debris [J].
Angelini, A ;
Reimers, B ;
Della Barbera, M ;
Saccà, S ;
Pasquetto, G ;
Cernetti, C ;
Valente, M ;
Pascotto, P ;
Thiene, G .
STROKE, 2002, 33 (02) :456-461
[2]   Diffusion-weighted magnetic resonance imaging in carotid angioplasty and stenting with balloon embolic protection devices [J].
Asakura, F ;
Kawaguchi, K ;
Sakaida, H ;
Toma, N ;
Matsushima, S ;
Kuraishi, K ;
Tanemura, H ;
Miura, Y ;
Maeda, M ;
Taki, W .
NEURORADIOLOGY, 2006, 48 (02) :100-112
[3]   Pseudo-no-reflow phenomenon in ostial saphenous vein graft intervention using FilterWire EX protection [J].
Lee, CH ;
Low, A ;
Tan, HC ;
Lim, YT .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 104 (02) :233-234
[4]   Filter no reflow during percutaneous coronary interventions using the Filterwire distal protection device [J].
Porto, I ;
Choudhury, RP ;
Pillay, P ;
Burzotta, F ;
Trani, C ;
Niccoli, G ;
Blackman, DJ ;
Channon, KM ;
Banning, AP .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 109 (01) :53-58
[5]   Morphometric analysis of particulate debris extracted by four different embolic protection devices from coronary arteries, aortocoronary saphenous vein conduits, and carotid arteries [J].
Quan, VH ;
Huynh, R ;
Seifert, PA ;
Kuchela, A ;
Chen, WH ;
Sütsch, G ;
Eisenhauer, AC ;
Rogers, C .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (12) :1415-1419
[6]   Embolic protection with filtering or occlusion balloons during saphenous vein graft stenting retrieves identical volumes and sizes of particulate debris [J].
Rogers, C ;
Huynh, R ;
Seifert, PA ;
Chevalier, B ;
Schofer, J ;
Edelman, ER ;
Toegel, G ;
Kuchela, A ;
Woupio, A ;
Kuntz, RE ;
Macon, ND .
CIRCULATION, 2004, 109 (14) :1735-1740
[7]   Protected carotid-artery stenting versus endarterectomy in high-risk patients [J].
Yadav, JS ;
Wholey, MH ;
Kuntz, RE ;
Fayad, P ;
Katzen, BT ;
Mishkel, GJ ;
Bajwa, TK ;
Whitlow, P ;
Strickman, NE ;
Jaff, MR ;
Popma, JJ ;
Snead, DB ;
Cutlip, DE ;
Firth, BG ;
Ouriel, K .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (15) :1493-1501