Evaluation of the gait performance of above-knee amputees while walking with 3R20 and 3R15 knee joints

被引:0
作者
Taheri, AliReza [1 ]
Karimi, Mohammad Taghi [1 ]
机构
[1] Isfahan Univ Med Sci, Rehabil Fac, Rehabil Engn Res Ctr, Dept Orthot & Prosthet,Sch Rehabil, Esfahan, Iran
来源
JOURNAL OF RESEARCH IN MEDICAL SCIENCES | 2012年 / 17卷 / 03期
关键词
Amputation; artificial limbs; gait; knee prosthesis; SWING-PHASE CONTROL; PROSTHESES; KINEMATICS; BALANCE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The performance of the subjects with above-knee amputation is noticeably poorer than normal subjects. Various types of components have been designed to compensate their performance. Among various prosthetic components, the knee joint has great influence on the function. Two types of knee joints (3R15, 3R20) have been used broadly for above-knee prostheses. However, there is not enough research to highlight the influence of these joints on the gait performance of the subjects. Therefore, an aim of this research was to investigate the performance of the above-knee amputees while walking with 3R15 and 3R20 knee joints. Materials and Methods: 7 above-knee amputees were recruited in this research study. They were asked to walk with a comfortable speed to investigate the gait function of the subjects with 3 cameras 3D motion analysis system (Kinematrix system). The difference between the performances of the subjects with these joints was compared by use of paired t-test. Results: The results of this study showed that, the performances of the subjects with 3R20 were better than that with 3R15. The walking speed of the subjects with 3R20 was 66.7 m/min compared to 30.4 m/min (P-value = 0.045). Moreover; the symmetry of walking with 3R20 was more than that with 3R15, based on the spatio-temporal gait parameters values (P-value < 0.05). Conclusion: The difference between the performances of the subjects with 3R20 and 3R15 knee joints was related to the walking speed, which improved while walking with 3R20 joint.
引用
收藏
页码:258 / 263
页数:6
相关论文
共 5 条
  • [1] Analysis of the 3R15 and C-Leg Knee Prosthesis
    Moraes, C. R. L.
    de Lima, V. J. B.
    de Souza, C. C. B.
    Inocencio, A. V. M.
    Mochel, B.
    Rodrigues, C.
    Rodrigues, M. A. B.
    XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL 1, 2019, 70 (01): : 125 - 128
  • [2] Unilateral above-knee amputees achieve symmetric mediolateral ground reaction impulse in walking using an asymmetric gait strategy
    Hisano, Genki
    Hashizume, Satoru
    Kobayashi, Toshiki
    Major, Matthew J.
    Nakashima, Motomu
    Hobara, Hiroaki
    JOURNAL OF BIOMECHANICS, 2021, 115
  • [3] Mobility analysis of amputees (MAAT 3): Matching individuals based on comorbid health reveals improved function for above-knee prosthesis users with microprocessor knee technology
    Wurdeman, Shane R.
    Stevens, Phillip M.
    Campbell, James H.
    ASSISTIVE TECHNOLOGY, 2020, 32 (05) : 236 - 242
  • [4] A new passive transfemoral prosthesis mechanism based on 3R36 knee and ESAR foot providing walking and squatting
    Imran, Amer
    Beigzadeh, Borhan
    Haghjoo, Mohammad Reza
    THEORETICAL AND APPLIED MECHANICS LETTERS, 2023, 13 (05)
  • [5] Obstacle course: Users' maneuverability and movement efficiency when using Otto Bock C-Leg, Otto Bock 3R60, and CaTech SNS prosthetic knee joints
    Meier, Margrit R.
    Hansen, Andrew H.
    Gard, Steven A.
    McFadyen, Angus K.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2012, 49 (04) : 583 - 596