Low-cost customizable microscale toolkit for rapid screening and purification of therapeutic proteins

被引:9
作者
Andar, Abhay U. [1 ]
Deldari, Sevda [2 ]
Gutierrez, Erick [1 ]
Burgenson, David [1 ]
Al-Adhami, Mustafa [1 ]
Gurramkonda, Chandrasekhar [1 ]
Tolosa, Leah [1 ]
Kostov, Yordan [1 ]
Frey, Douglas D. [2 ]
Rao, Govind [1 ,2 ]
机构
[1] Univ Maryland Baltimore Cty, Ctr Adv Sensor Technol, 1000 Hilltop Circle,TRC 252A, Baltimore, MD 21250 USA
[2] Univ Maryland Baltimore Cty, Dept Chem Biochem & Environm Engn, 1000 Hilltop Circle,TRC 252B, Baltimore, MD 21250 USA
关键词
chromatography; granulocyte colony stimulating factor; immobilized metal affinity chromatography; microfluidics; protein purification; CHROMATOGRAPHY; INTEGRATION;
D O I
10.1002/bit.26876
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Biopharmaceutical separations require tremendous amounts of optimization to achieve acceptable product purity. Typically, large volumes of reagents and biological materials are needed for testing different parameters, thus adding to the expense of biopharmaceutical process development. This study demonstrates a versatile and customizable microscale column (mu Col) for biopharmaceutical separations using immobilized metal affinity chromatography (IMAC) as an example application to identify key parameters. mu Cols have excellent precision, efficiency, and reproducibility, can accommodate any affinity, ion-exchange or size-exclusion-based resin and are compatible with any high-performance liquid chromatography (HPLC) system. mu Cols reduce reagent amounts, provide comparable purification performance and high-throughput, and are easy to automate compared with current conventional resin columns. We provide a detailed description of the fabrication methods, resin packing methods, and mu Col validation experiments using a conventional HPLC system. Finite element modeling using COMSOL Multiphysics was used to validate the experimental performance of the mu Cols. In this study, mu Cols were used for improving the purification achieved for granulocyte colony stimulating factor (G-CSF) expressed using a cell-free CHO in vitro translation (IVT) system and were compared to a conventional 1 ml IMAC column. Experimental data revealed comparable purity with a 10-fold reduction in the amount of buffer, resin, and purification time for the mu Cols compared with conventional columns for similar protein yields.
引用
收藏
页码:870 / 881
页数:12
相关论文
共 37 条
[1]   Point-of-care production of therapeutic proteins of good-manufacturing-practice quality [J].
Adiga, Rajani ;
Al-adhami, Mustafa ;
Andar, Abhay ;
Borhani, Shayan ;
Brown, Sheniqua ;
Burgenson, David ;
Cooper, Merideth A. ;
Deldari, Sevda ;
Frey, Douglas D. ;
Ge, Xudong ;
Guo, Hui ;
Gurramkonda, Chandrasekhar ;
Jensen, Penny ;
Kostov, Yordan ;
LaCourse, William ;
Liu, Yang ;
Moreira, Antonio ;
Mupparapu, KarunaSri ;
Penalber-Johnstone, Chariz ;
Pilli, Manohar ;
Punshon-Smith, Benjamin ;
Rao, Aniruddha ;
Rao, Govind ;
Rauniyar, Priyanka ;
Snovida, Sergei ;
Taurani, Kanika ;
Tilahun, Dagmawi ;
Tolosa, Leah ;
Tolosa, Michael ;
Tran, Kevin ;
Vattem, Krishna ;
Veeraraghavan, Sudha ;
Wagner, Brandon ;
Wilhide, Joshua ;
Wood, David W. ;
Zuber, Adil .
NATURE BIOMEDICAL ENGINEERING, 2018, 2 (09) :675-686
[2]  
Al-Adhami M., 2016, ADV ENV CHEM BIOL SE, V9862, P1
[3]   A new simple and fast thermally-solvent assisted method to bond PMMA-PMMA in micro-fluidics devices [J].
Bamshad, Arshya ;
Nikfarjam, Alireza ;
Khaleghi, Hossein .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2016, 26 (06)
[4]   IMMOBILIZED-METAL AFFINITY CHROMATOGRAPHY (IMAC): A REVIEW [J].
Block, Helena ;
Maertens, Barbara ;
Spriestersbach, Anne ;
Brinker, Nicole ;
Kubicek, Jan ;
Fabis, Roland ;
Labahn, Joerg ;
Schaefer, Frank .
GUIDE TO PROTEIN PURIFICATION, SECOND EDITION, 2009, 463 :439-473
[5]  
Bunner B., 2008, EXC P COMSOL C BOST, P1
[6]   Fully automated protein purification [J].
Camper, DeMarco V. ;
Viola, Ronald E. .
ANALYTICAL BIOCHEMISTRY, 2009, 393 (02) :176-181
[7]  
Chan A. S., 2014, J ANAL METHODS CHEM, V2014, P2014
[8]  
Clontech Laboratories, 2011, PROT PUR PROD MAN
[9]  
Clontech Laboratories, 2004, TALON MET AFF RES US
[10]   EQUATIONS FOR CALCULATION OF CHROMATOGRAPHIC FIGURES OF MERIT FOR IDEAL AND SKEWED PEAKS [J].
FOLEY, JP ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :730-737