ULTRASOUND ASSESSMENT OF TRANSVERSE CARPAL LIGAMENT THICKNESS: A VALIDITY AND RELIABILITY STUDY

被引:27
作者
Shen, Zhilei Liu [1 ]
Li, Zong-Ming [1 ]
机构
[1] Cleveland Clin, Dept Biomed Engn, Cleveland, OH 44195 USA
基金
美国国家卫生研究院;
关键词
Ultrasound; Transverse carpal ligament; Validity; Reliability; TUNNEL SYNDROME; IMAGING MEASUREMENTS; ACHILLES-TENDON; REPRODUCIBILITY; SIZE; RELEASE;
D O I
10.1016/j.ultrasmedbio.2012.02.021
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The transverse carpal ligament (TCL) forms the palmar boundary of the carpal tunnel and plays an important role in carpal tunnel mechanics. TCL hypertrophy has been observed for individuals with carpal tunnel syndrome (CTS) and postulated as a potential etiologic factor. Ultrasound is particularly advantageous for TCL imaging because of its capability of detecting the interfaces between the TCL and other tissues. The purposes of this study were to develop an ultrasound based method to measure the TCL thickness and to test the validity and reliability of this method. Three operators conducted two sessions of ultrasound examination on eight cadaveric specimens and eight healthy volunteers. A custom script was used to calculate TCL thickness along the TCL length from the ultrasound images. The ultrasound based TCL thickness of the cadaveric specimens was compared with the dissection based TCL thickness for validation. The results showed Pearson's correlation coefficients of 0.867-0.928, intraclass correlation coefficient (ICC) values of 0.726-0.865, a standard error of measurement of 0.02-0.07 mm and a minimal detectable difference of 0.05-0.15 mm. The high correlation coefficients and small errors indicate that the ultrasound based method is valid for measuring TCL thickness. Furthermore, ultrasound measurements showed excellent intraoperator and interoperator reliability with ICC values as 0.826-0.933 and 0.840-0.882, respectively. The ultrasound based TCL thickness was in the range of 0.93-2.34 (1.54 +/- 0.33) mm and agreed well with previous studies. The ultrasound method developed in this study is a valuable tool to examine morphologic properties of healthy and pathologic TCLs. (E-mail: liz4@ccf.org) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:982 / 988
页数:7
相关论文
共 29 条
[1]  
Balint PV, 2001, CLIN EXP RHEUMATOL, V19, P89
[2]   Thickness of the middle trapezius muscle measured by rehabilitative ultrasound imaging: description of the technique and reliability study [J].
Bentman, Susanna ;
O'Sullivan, Cliona ;
Stokes, Maria .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2010, 30 (06) :426-431
[3]   Biomechanical and anatomical consequences of carpal tunnel release [J].
Brooks, JJ ;
Schiller, JR ;
Allen, SD ;
Akelman, E .
CLINICAL BIOMECHANICS, 2003, 18 (08) :685-693
[4]   Reproducibility of ultrasound and magnetic resonance imaging measurements of tendon size [J].
Brushoj, C. ;
Henriksen, B. M. ;
Albrecht-Beste, E. ;
Holmich, P. ;
Larsen, K. ;
Nielsen, M. Bachmann .
ACTA RADIOLOGICA, 2006, 47 (09) :954-959
[5]   M-mode ultrasound: a reliable measure of transversus abdominis thickness? [J].
Bunce, SM ;
Moore, AP ;
Hough, AD .
CLINICAL BIOMECHANICS, 2002, 17 (04) :315-317
[6]   ANATOMY OF THE FLEXOR RETINACULUM [J].
COBB, TK ;
DALLEY, BK ;
POSTERARO, RH ;
LEWIS, RC .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (01) :91-99
[7]   Reliability of Quantitative Ultrasound Measures of the Biceps and Supraspinatus Tendons [J].
Collinger, Jennifer L. ;
Gagnon, Dany ;
Jacobson, Jon ;
Impink, Bradley G. ;
Boninger, Michael L. .
ACADEMIC RADIOLOGY, 2009, 16 (11) :1424-1432
[8]  
Ferrari F S, 1997, Radiol Med, V93, P336
[9]   On the ultrasonic properties of tendon [J].
Garcia, T ;
Hornof, WJ ;
Insana, MF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (12) :1787-1797
[10]   THE CARPAL-TUNNEL SYNDROME - A STUDY OF CARPAL CANAL PRESSURES [J].
GELBERMAN, RH ;
HERGENROEDER, PT ;
HARGENS, AR ;
LUNDBORG, GN ;
AKESON, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (03) :380-383