Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT

被引:24
作者
Cao, Qian [1 ]
Zbijewski, Wojciech [1 ]
Sisniega, Alejandro [1 ]
Yorkston, John [2 ]
Siewerdsen, Jeffrey H. [1 ,3 ]
Stayman, J. Webster [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Carestream Hlth, Rochester, NY 14608 USA
[3] Johns Hopkins Univ, Russell H Morgan Dept Radiol, Baltimore, MD 21205 USA
基金
美国国家卫生研究院;
关键词
CBCT; model-based reconstruction; multiresolution; bone; extremity; IMAGE QUALITY; TOMOGRAPHIC RECONSTRUCTION; BREAST CT; ALGORITHMS; REGION; SYSTEM; DESIGN; MODELS;
D O I
10.1088/0031-9155/61/20/7263
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Application of model-based iterative reconstruction (MBIR) to high resolution cone-beam CT (CBCT) is computationally challenging because of the very fine discretization (voxel size <100 mu m) of the reconstructed volume. Moreover, standard MBIR techniques require that the complete transaxial support for the acquired projections is reconstructed, thus precluding acceleration by restricting the reconstruction to a region-of-interest. To reduce the computational burden of high resolution MBIR, we propose a multiresolution penalized-weighted least squares (PWLS) algorithm, where the volume is parameterized as a union of fine and coarse voxel grids as well as selective binning of detector pixels. We introduce a penalty function designed to regularize across the boundaries between the two grids. The algorithm was evaluated in simulation studies emulating an extremity CBCT system and in a physical study on a test-bench. Artifacts arising from the mismatched discretization of the fine and coarse sub-volumes were investigated. The fine grid region was parameterized using 0.15 mm voxels and the voxel size in the coarse grid region was varied by changing a downsampling factor. No significant artifacts were found in either of the regions for downsampling factors of up to 4x. For a typical extremities CBCT volume size, this downsampling corresponds to an acceleration of the reconstruction that is more than five times faster than a brute force solution that applies fine voxel parameterization to the entire volume. For certain configurations of the coarse and fine grid regions, in particular when the boundary between the regions does not cross high attenuation gradients, downsampling factors as high as 10x can be used without introducing artifacts, yielding a similar to 50x speedup in PWLS. The proposed multiresolution algorithm significantly reduces the computational burden of high resolution iterative CBCT reconstruction and can be extended to other applications of MBIR where computationally expensive, high-fidelity forward models are applied only to a sub-region of the field-of-view.
引用
收藏
页码:7263 / 7281
页数:19
相关论文
共 44 条
  • [1] Microcomputed tomography: approaches and applications in bioengineering
    Boerckel, Joel D.
    Mason, Devon E.
    McDermott, Anna M.
    Alsberg, Eben
    [J]. STEM CELL RESEARCH & THERAPY, 2014, 5
  • [2] Dedicated breast CT: Radiation dose and image quality evaluation
    Boone, JM
    Nelson, TR
    Lindfors, KK
    Seibert, JA
    [J]. RADIOLOGY, 2001, 221 (03) : 657 - 667
  • [3] Tomographic image reconstruction based on a content-adaptive mesh model
    Brankov, JG
    Yang, Y
    Wernick, MN
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (02) : 202 - 212
  • [4] Combined algorithmic and GPU acceleration for ultra-fast circular conebeam backprojection
    Brokish, Jeffrey
    Sack, Paul
    Bresler, Yoram
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [5] Dedicated Cone-Beam CT System for Extremity Imaging
    Carrino, John A.
    Al Muhit, Abdullah
    Zbijewski, Wojciech
    Thawait, Gaurav K.
    Stayman, J. Webster
    Packard, Nathan
    Senn, Robert
    Yang, Dong
    Foos, David H.
    Yorkston, John
    Siewerdsen, Jeffrey H.
    [J]. RADIOLOGY, 2014, 270 (03) : 816 - 824
  • [6] Micro-CT of rodents: State-of-the-art and future perspectives
    Clark, D. P.
    Badea, C. T.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (06): : 619 - 634
  • [7] Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature
    De Vos, W.
    Casselman, J.
    Swennen, G. R. J.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (06) : 609 - 625
  • [8] Degirmenci S, 2015, P SPIE COMP IM 13, VXIII
  • [9] Statistical image reconstruction for polyenergetic X-ray computed tomography
    Elbakri, IA
    Fessler, JA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) : 89 - 99
  • [10] Ordered subsets algorithms for transmission tomography
    Erdogan, H
    Fessler, JA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) : 2835 - 2851